SEH50-SEH100-SEH200
Heavy Duty High Head Sewage Pumps
OPERATION MANUAL
Dated: 03/22/2018
Document Name: SEH50-SEH100-SEH200_OM
Page 4 of 12
www.ionproducts.net
Important
1 Phase Models
Model Number:
Prior to installation, record Model
Number, MFG Date, Amps,
Voltage, Phase and HP, from pump
nameplate for future reference.
Also record the voltage and current
readings at startup.
Amps:
Volts:
MFG Date:
3 Phase Models
Phase:
Amps L1-2:
Volts L1-2:
HP:
Amps L2-3:
Volts L2-3:
SN:
Amps L3-3:
Volts L3-3:
Model
HP
Volt
Ph
Nema Start
Code
FLA
Cord Size
Cord Type
Cord O.D.
Inches
SEH50M-11
0.5
60
115/1
3450
12.0
SOW
16/3
0.43
SEH50M-21
0.5
60
230/1
3450
6.0
SOW
16/3
0.43
SEH50M-03
0.5
60
208/3
3450
4.2
SOW
16/4
0.46
SEH50M-23
0.5
60
230/3
3450
4.0
SOW
16/4
0.46
SEH50M-43
0.5
60
460/3
3450
2.0
SOW
16/4
0.46
SEH100M-21
1
60
230/1
3450
11.0
SOW
16/3
0.43
SEH100M-03
1
60
208/3
3450
6.8
SOW
16/4
0.46
SEH100M-23
1
60
230/3
3450
6.6
SOW
16/4
0.46
SEH100M-43
1
60
460/3
3450
3.3
SOW
16/4
0.46
SEH200M-21
2
60
230/1
3450
18.0
SOW
14/3
0.575
SEH200M-03
2
60
208/3
3450
10.4
SOW
16/4
0.46
SEH200M-23
2
60
230/3
3450
9.0
SOW
16/4
0.46
SEH200M-43
2
60
460/3
3450
4.5
SOW
16/4
0.46
Specifications