background image

SEH50-SEH100-SEH200

Heavy Duty High Head Sewage Pumps

OPERATION MANUAL

Dated: 03/22/2018

Document Name: SEH50-SEH100-SEH200_OM

Page 4 of 12

www.ionproducts.net

Important

1 Phase Models

Model Number:

Prior to installation, record Model 

Number, MFG Date, Amps, 

Voltage, Phase and HP, from pump 

nameplate for future reference. 

Also record the voltage and current 

readings at startup.

Amps:

Volts:

MFG Date:

3 Phase Models

Phase:

Amps L1-2:

Volts L1-2:

HP:

Amps L2-3:

Volts L2-3:

SN:

Amps L3-3:

Volts L3-3:

Model

HP

Volt

Ph

Nema Start 

Code

FLA

Cord Size

Cord Type

Cord O.D.  

Inches

SEH50M-11

0.5

60

115/1

3450

12.0

SOW

16/3

0.43

SEH50M-21

0.5

60

230/1

3450

6.0

SOW

16/3

0.43

SEH50M-03

0.5

60

208/3

3450

4.2

SOW

16/4

0.46

SEH50M-23

0.5

60

230/3

3450

4.0

SOW

16/4

0.46

SEH50M-43

0.5

60

460/3

3450

2.0

SOW

16/4

0.46

SEH100M-21

1

60

230/1

3450

11.0

SOW

16/3

0.43

SEH100M-03

1

60

208/3

3450

6.8

SOW

16/4

0.46

SEH100M-23

1

60

230/3

3450

6.6

SOW

16/4

0.46

SEH100M-43

1

60

460/3

3450

3.3

SOW

16/4

0.46

SEH200M-21

2

60

230/1

3450

18.0

SOW

14/3

0.575

SEH200M-03

2

60

208/3

3450

10.4

SOW

16/4

0.46

SEH200M-23

2

60

230/3

3450

9.0

SOW

16/4

0.46

SEH200M-43

2

60

460/3

3450

4.5

SOW

16/4

0.46

Specifications

Содержание SEH100M-03

Страница 1: ...he operator that the failure to follow an instruction may damage the pump and or the system Safety Warnings CAUTION Read these safety warnings first before installing servicing or operating any pump B...

Страница 2: ...NING Installation wiring and junction connections must be in accordance with the National Electric Code and all applicable state and local codes Requirements may vary depending on usage and location W...

Страница 3: ...quently Never handle connected power cords with wet hands Never let cords or plugs lie in water outside the pit These pumps are offered in a three phase and single phase wiring configuration Voltages...

Страница 4: ...odel HP Volt Ph Nema Start Code FLA Cord Size Cord Type Cord O D Inches SEH50M 11 0 5 60 115 1 3450 12 0 SOW 16 3 0 43 SEH50M 21 0 5 60 230 1 3450 6 0 SOW 16 3 0 43 SEH50M 03 0 5 60 208 3 3450 4 2 SOW...

Страница 5: ...s and connected to discharge pipe so that space is provided under pump for entrance of sewage Pump inlet should not be closer than 2 inches from bottom of sump It is not generally desirable to install...

Страница 6: ...per motor rotation can result in poor pump performance and can damage the motor and or pump Identification Plate Note the numbers on the pumps identification plate and record in this manual for future...

Страница 7: ...ags or labels have been removed 5 Used in a heavy grease application 6 Used in applications exceeding the designed temperature range of 32 104 degrees F Troubleshooting Pump does not run and or just h...

Страница 8: ...5010 2 BEARING 10 091EP5011 1 C RING 11 091EP7512 1 ROTOR ASSY 1 2 HP 091EP1012 1 ROTOR ASSY 1 0 HP 091SWH212 1 ROTOR ASSY 2 0 HP 12 091EP5013 1 SPRING WASHER 13 091EP5014 1 TOP COVER 14 091EP5015 1 G...

Страница 9: ...High Head Sewage Pumps OPERATION MANUAL Dated 03 22 2018 Document Name SEH50 SEH100 SEH200_OM Page 9 of 12 www ionproducts net Exploded View 1 2 3 4 5 7 8 9 11 13 16 17 18 5 19 20 21 22 23 14 15 25 26...

Страница 10: ...SEH50 SEH100 SEH200 Heavy Duty High Head Sewage Pumps OPERATION MANUAL Dated 03 22 2018 Document Name SEH50 SEH100 SEH200_OM Page 10 of 12 www ionproducts net Notes...

Страница 11: ...SEH50 SEH100 SEH200 Heavy Duty High Head Sewage Pumps OPERATION MANUAL Dated 03 22 2018 Document Name SEH50 SEH100 SEH200_OM Page 11 of 12 www ionproducts net Notes...

Страница 12: ...orrect a defect in a product shall extend the Warranty beyond the period set forth above Metropolitan shall not be obligated to remedy any defect where otherwise required pursuant to the Warranty unle...

Отзывы: