Verify Mode by RS485:
It is the verification mode used by the device when it is the master unit.
This option will be displayed only if RS485 reader function is enabled.
You can enable it by following these steps: In the initial interface, press
[M/OK]
>
COMM.
>
Serial
Comm
>
Serial Port
>
Master Unit
.
Valid holidays:
To set if
NC Time Period
or
NO Time Period
settings are valid in set holiday time
period. Choose
[ON]
to enable the set
NC
or
NO
time period in holiday.
Speaker Alarm:
When the
[Speaker Alarm]
is enabled, the speaker will raise an alarm when the
device is being dismantled.
Reset Access Setting:
To reset parameters of door lock delay, door sensor delay, door sensor type,
door alarm delay, retry times to alarm, NC time period, NO time period, valid holidays, speaker
alarm, device status, duress function, alarm on 1:1 match, alarm on 1: N match, alarm on password
and alarm delay. However, the content of the Access Data Deletion in
[Data Mgt.]
will not be
affected.
Note:
After setting
NC Time Period
, please lock the door well, otherwise alarm might be triggered
during
NC Time Period
.
Defining Time Schedules
Time Schedule is the minimum time unit of access control settings; at most 50
Time Schedules
can
be set for the system. Each
Time Schedule
consists of 7 time sections (a week), and each time
section is the valid time within 24 hrs. Enter into
“
Access Control
”
→
”
Time Schedule
”
.
The default Time Schedule No. is 1 (whole-day valid), which can be edited.
Valid Time Schedule:
00:00 ~ 23:59 (Whole-day valid) or when the end time is greater than the
start time.
Invalid Time Schedule:
When the end time is smaller than the start time.
The following examples as explanation: