Barrier configuration
Adapter for barrier assembly
Barrier installation for protection of a wall or window
requires the sensor to be installed at approximately
15 cm (5.9 in) from the same wall. If other adequate
supports are not available, an adapter is necessary
for assembling the barrier (product code: MSK-101-
BM.
Figure 8
- Example of installation without adapter.
Figure 9
- Example of installation with MSK-101-BM adapter.
Sensor direction
The MSK-101-BM adapter, according to the
installation method, allows directing the sensor to the
left or the right.
Figure 10
- Sensor directed towards the left.
Figure 11
- Sensor directed towards the right.
Field of vision
Range of the field with horizontal
sensor direction (volumetric)
In this installation the visual field of the sensor is
approximately 90° along the horizontal plane and 30°
on the vertical plane. It extends for a maximum of 20
m, following the radiation pattern of the antenna.
Figure 12
- Top view.
Figure 13
- Side view.
Range of the field with vertical
sensor direction (barrier)
In this installation the visual field of the sensor is
approximately 30° along the horizontal plane and 70°
on the vertical plane. It extends for a maximum of 20
m, following the radiation pattern of the antenna.
Figure 14
- Top view.
Figure 15
- Side view.
Useful information for design
MSK-101 | Advanced configuration manual v1.5 MAY 2018 | msk-101_advanced-config_en_wo v1.5 | © 2017-2018 Inxpect SpA
11