INVT iMarsBD-HS Скачать руководство пользователя страница 1

 

 

 

Operation

 Manual 

iMarsBD-HS   

Energy Storage Integrated Machine 

 

 

 

 

Содержание iMarsBD-HS

Страница 1: ...Operation Manual iMarsBD HS Energy Storage Integrated Machine...

Страница 2: ......

Страница 3: ...autions seriously before any moving installation operation and maintenance to ensure correct use and high performance of operation on the machine The use of the energy storage integrated machine must...

Страница 4: ...ensions and weight 9 3 Storage of the energy storage integrated machine 11 4 Installation 12 4 1 Unpacking confirmation 12 4 2 Preparation before installation 14 4 2 1 Installation tools 14 4 3 Mechan...

Страница 5: ...ication connection 27 5 LCD operation instructions 30 5 1 Instruction for main page 30 5 2 Display menu 31 5 3 Parameter setup of the energy storage integrated machine 32 5 3 1 Parameter classificatio...

Страница 6: ...es Statement Our company shall not be liable for any consequence caused by any of the following events Damage caused by transportation The storage conditions do not meet the requirements specified in...

Страница 7: ...g of the device Note 1 2 Safety guide After receiving this product first confirm the product package is intact If any question contact the logistic company or local distributor immediately The install...

Страница 8: ...ety regulations for electrical systems Operators need to be fully familiar with the composition and operating principle of the entire energy storage system and related standards of the countries regio...

Страница 9: ...nstallation and electrical connection before operation Do not open the cover of the machine when the machine is working or any circuit is connecting to the machine 1 2 3 Maintenance and replacement On...

Страница 10: ...of the grid or running system otherwise electric shock or fire may occur Please do not ignore the warning icons and instructions with electric shock 1 2 4 What to do after scrapping Do not dispose of...

Страница 11: ...ly describes the appearance packaging accessories nameplate and other information of iMars series energy storage integrated machines 2 1 Energy storage system Figure 2 1 Energy storage system Symbol D...

Страница 12: ...of 3 5 kW energy storage integrated machine No Name Description 1 Energy storage integrated machine 2 Touch screen 3 Energy storage inverter 4 Battery break 5 Lithium battery Purchased separately 6 l...

Страница 13: ...n 4 PV connection terminal block PV DC input terminal of the inverter 5 RS485 3 RS485 3 communication port 6 RS485 1 2 RS485 1 2 communication port 7 Battery CAN1 Battery CAN communication interface n...

Страница 14: ...Energy storage integrated machine Product overview 8 2 2 2 Nameplate Figure 2 4 Nameplate for the machine...

Страница 15: ...ve EU WEEE mark Cannot dispose of the machine as household waste 2 3 Products modules Product name Model Rated output power W Single phase L N and PE Single phase energy storage integrated machine 3kW...

Страница 16: ...Energy storage integrated machine Product overview 10 Figure 2 6 Paper package size Package size and gross weight Model H mm W mm D mm Net weight kg 3kW 5kW 1250 770 720 90...

Страница 17: ...n and dry place and prevent the erosion of dust and water vapor The storage temperature should be kept at 20 C 60 C and the relative humidity should be kept at 4 RH 100 RH Keep away from chemically co...

Страница 18: ...ts original package and take anti moisture and anti dust measures After taking the machine out of the box check the following items Confirm the main body of the machine is intact and free from any dam...

Страница 19: ...tity remarks A 3 kW 5 kW energy storage integrated machine cabinet 1 B communication connector 2 C RS485 communication connector 1 D DRM0 communication connector 1 E RS485 Communication link 1 F RJ45...

Страница 20: ...Energy storage integrated machine Installation 14 4 2 Preparation before installation 4 2 1 Installation tools...

Страница 21: ...Energy storage integrated machine Installation 15 Figure 4 2 Installation spacing...

Страница 22: ...e shall be well ventilated free from rain and direct sunlight The installation floor shall be dry and flat It is strictly forbidden to have water on the ground ensure that the ground level is not shak...

Страница 23: ...arton and cushioning material remove the L shaped iron piece for fixing the machine and pallet and separate the energy storage integrated machine from the pallet Figure 4 4 Step 3 Place the ramp into...

Страница 24: ...y because it belongs to free choice of goods Due to the system design and machine structure and size it is recommended to use the battery product US2000B recommended by our company Electrical connecti...

Страница 25: ...ect to the iMars series energy storage integrated machines Reverse polarity of the battery will damage the energy storage integrated machines Please ensure that the wiring is correct otherwise our com...

Страница 26: ...tion port RS232 Used to communicate with the host computer 8 External CAN communication port CAN Used to communicate with external devices power storage inverter 9 External RS485 communication port RS...

Страница 27: ...t 25 A Delay 15 s protection 1 min recovery after protection or immediate recovery upon the occurrence of discharge current Internal resistance in battery pack excluding BMS Internal resistance 20 m C...

Страница 28: ...8 screw connection and 6 8 N m torque Step 3 According to the number of batteries connect the battery parallel communication cables with the RJ45 cables Connected from top to bottom Link port 0 of the...

Страница 29: ...ion 4 4 5 PV connection Only qualified PV strings under the local electrical safety laws and regulations and comply with the technical parameters of this manual are allowed to connect to the iMars ser...

Страница 30: ...f the PV strings otherwise it will cause damage to the energy storage integrated machine Ensure that the PV string polarity matches the PV connector otherwise the energy storage integrated machine wil...

Страница 31: ...he DC input cable and ensure that the voltage of each string is within the allowable range of the machine Figure 4 15 Measuring PV voltage 4 4 6 Grid and load connection Only qualified AC transmission...

Страница 32: ...Figure 4 16 Stripping length and crimping of wires L N and PE of the mains and load cables Terminal crimping of wires L N and PE of the mains and load cables Terminal crimping torque 3 6 4 6 N m Figu...

Страница 33: ...1 2 3 4 5 6 7 8 GND CANH CANL 4 4 8 Definition of CAN2 interface pin in the energy storage inverter Figure 4 19 CAN2 communication wiring diagram 1 2 3 CANH1 CANL1 GND 4 4 9 RS 485 communication conne...

Страница 34: ...chine Installation 28 Table 3 4 and 3 5 Figure 4 20 Diagram of RS 485 1 2 interface Table 3 4 RS 485 1 2 communication interface definition Port no Port definition 1 RS1 485 2 RS1 485 3 RS2 485 4 5VDC...

Страница 35: ...ion interface definition Connector pin of the energy storage integrated machine communication Pin definition 1 5VDC 2 A RS3485 3 B RS3485 4 GND Users can select RS 485 1 2 3 to communicate during RS 4...

Страница 36: ...Icon instruction Icon Instruction PV information displaying parameters related to PV panel such as PV voltage current power etc Inverter data display and parameter setting Grid information displaying...

Страница 37: ...on 8 Monthly generation 9 Annual generation 10 Total generation Energy storage integrated machine information 1 operation 2 Alarm 3 Power curve 4 Configuration Grid information 1 Grid voltage 2 Grid c...

Страница 38: ...rent power 5 Daily consumption 6 Monthly consumption 7 Annual consumption 8 Total consumption 5 3 Parameter setup of the energy storage integrated machine 5 3 1 Parameter classification page The param...

Страница 39: ...y protocol Battery protocol Battery protocol 1 Pylon 2 Sunwoda 3 Yinlong 4 Xstellar 5 FES 6 Olipower 7 DLG 8 GCL 3 Charge voltage Charge voltage Charge voltage range 0 60 V 4 Charge current Charge cur...

Страница 40: ...tarts Start time of charge time period 3 range 0 23 59 Charge time period 3 ends End time of charge time period 3 range 0 23 59 12 Discharge time period 3 setup Discharge time period 3 starts Start ti...

Страница 41: ...ing mode Working mode of the inverter 2 Temperature Temperature in the inverter 3 Device type 4 Production data 5 Auxiliary DSP software version no 6 Product SN 7 Grid tied standard 8 Hardware version...

Страница 42: ...Ac voltage low1 04 Ac voltage low2 05 Ac freq high1 06 Ac freq high2 07 Ac freq low1 08 Ac freq low2 09 Ac over currhw 10 Ac over currsw 11 Bus over volt hw 12 Bus over volt sw 13 Gfci over 14 Gfci se...

Страница 43: ...Load over current 38 Battery over current 39 Battery volt high 40 Battery open 41 Quik stop 42 Pv1 over current hw 43 Pv2 over current hw 44 Bat over current hw 45 LLC over current hw 46 LLC over volt...

Страница 44: ...AC output power 3000 W 4600 W Max AC output current 13 A 20 A Max output short circuit current 20 A 30 A Max output overcurrent protection 20 A 30 A Rated grid voltage grid voltage range 230 Vac 180 2...

Страница 45: ...side High frequency isolation Protection level IP20 Dimension H W D 1043 5 770 605 mm Protection function DC insulation monitoring DC monitoring grid monitoring islanding protection short circuit prot...

Страница 46: ...Solar Technology Shenzhen Co Ltd Address 6th Floor Block A INVT Guangming Technology Building Songbai Road Matian Guangming District Shenzhen China Service hotline 86 755 86312953 E mail invtsolarcn i...

Отзывы: