Goodrive350-19 series VFD for crane
Function parameter list
-205-
7 Function parameter list
7.1 What this chapter contains
This chapter lists all the function codes and corresponding description of each function code.
7.2 Function parameter list
The function parameters of the VFD are divided into groups by function. Among the function
parameter groups, groups P90
–P93 are hoisting function groups, P98 is the analog input and output
calibration group, while P99 contains the factory function parameters, which are user inaccessible.
Each group includes several function codes (each function code identifies a function parameter). A
three-level menu style is applied to function codes. For example, "
" indicates the 8th function
code in P08.
The function group numbers correspond to the level-1 menus, the function codes correspond to the
level-2 menus, and the function parameters correspond to the level-3 menus.
1.
The content of the function code table is as follows:
Column 1 "Function code ": Code of the function group and parameter
Column 2 "Name": Full name of the function parameter
Column 3 "Description": Detailed description of the function parameter
Column 4 "Default": Initial value set in factory
Column 5 "Modify": Whether the parameter can be modified, and conditions for the modification
"
○
" indicates that the value of the parameter can be modified when the VFD is in stopped or running
state.
"
◎
" indicates that the value of the parameter cannot be modified when the VFD is in running state.
"
●
" indicates that the value of the parameter is detected and recorded, and cannot be modified.
(The VFD automatically checks and constrains the modification of parameters, which helps prevent
incorrect modifications.)
2. The parameters adopt the decimal system (DEC). If the hexadecimal system is adopted, all bits
are mutually independent on data during parameter editing, and the setting ranges at some bits
can be hexadecimal (0
–F).
3. "Default" indicates the factory setting of the function parameter. If the value of the parameter is
detected or recorded, the value cannot be restored to the factory setting.
4. To better protect parameters, the VFD provides the password protection function. After a
is set to a non-zero value), "0.0.0.0.0" is displayed when you
press the PRG/ESC key to enter the function code editing interface. You need to enter the
correct user password to enter the interface. For the factory parameters, you need to enter the
correct factory password to enter the interface. (You are not advised to modify the factory