Goodrive300-01A series VFD for air compressor
Wiring instruction
-18-
3.2 Control circuit wiring and terminal description
Emergency-stop
Fan fault
User-defined
User-defined
COM
S4
S3
S2
S1
S5
PTB1
PTA1
PTB2
PTA2
P1-
P1+
P2-
P2+
Ib
Ia
Ic
GND
+24V
485-
485+
PT100
PT100
Pressure transmitter
Pressure transmitter
V
I
V
I
J7
J8
CN10
ON
0-10V/0-20mA
Analog output
AO1
GND
V
I
COM
PW
+24V
J9
J5
J2
J6
to current transformer
to power detection module
RO1C
RO1A
RO3C
RO3B
RO3A
Relay 1 output
Relay 3 output
RO2C
RO2A
Relay 2 output
GND
PE
GD300-01A series
--shielded cable
--twisted pair
to wireless data collection
terminal
to touch screen or
controller
GND
+24V
485-
485+
485+
GND
+24V
485-
CGND
/PE
CGND
J10
PE
CN7-10
User-defined
Figure 3-16 Control circuit wiring diagram
J7
J8
J2
J5
J6
J9
CN4
CN7
RO1ARO1CRO2ARO2CRO3ARO3BRO3C
CN8
CN10
CN7-10
+24V
PW
COM
J10
P1+
P1-
P2+
P2- PTA1 PTB1 PTA2 PTB2
COM
S1
S2
S3
S4
S5
COM COM
+24V GND 485+ 485-
Ia
Ib
Ic
+24V GND 485+ 485-
AO1
GND
PE/C
GND
+24V GND 485+ 485-
V
I
V
I
V
I
ON
PE
GND
PE
CGND
Figure 3-17 Control circuit terminal diagram
Table 3-5 User terminal description of control circuit
Category
Sign
Name
Function
Power
+24V
+24V power
P24V±5% power to the external,
max. output current: 1A
Can be used to power up GPRS, touch
screen and power detection module
GND
+24V, AO1, Ia, Ib, Ic
reference ground
+24V, AO, Ia, Ib, Ic reference ground
Содержание Goodrive300-01A Series
Страница 1: ......
Страница 175: ...6 6 0 0 1 0 0 5 5 3...