![INVT GD350-004G-4 Скачать руководство пользователя страница 286](http://html1.mh-extra.com/html/invt/gd350-004g-4/gd350-004g-4_operation-manual_2085703286.webp)
Goodrive350 series high-performance multifunction VFD
Function parameter list
-277-
Function
code
Name
Description
Default Modify
Tens place: Alarm mode
0: Stop in enabled stop mode without reporting an
alarm
1: Report an alarm and coast to stop
Hundreds place: Roll diameter memory function of
feeding interrupt
0: Disable
1: Enable
P92.14
Stop braking
frequency
0.00
–300.00Hz
1.50Hz
○
P92.15 Stop braking time 0.0
–600.0s
0.0s
○
P93
––
Tension control status viewing
Function
code
Name
Description
Default Modify
P93.00
Actual control
mode
0
–3
0: Invalid tension control
1: Close-loop tension speed control
2: Open loop tension torque control
3: Close-loop tension torque control
0
●
P93.01
Actual winding/
unwinding mode
0
–1
0: Winding
1: Unwinding
0
●
P93.02
Initial roll
diameter
0.0
–5000.0mm
0.0mm
●
P93.03
Reset roll
diameter
0.0
–5000.0mm
0.0mm
●
P93.04
Roll diameter
change rate
0.00
–655.35 mm/s
0.00
mm/s
●
P93.05
Present roll
diameter
0.0
–5000.0mm
0.0mm
●
P93.06
Roll diameter for
linear speed
calculation
0.0
–5000.0mm
0.0mm
●
P93.07 Set linear speed 0.0
–6000.0 m/min
0.0
m/min
●
P93.08
Present linear
speed
0.0
–6000.0 m/min
0.0
m/min
●
P93.09
Main reference 0.00
–600.00Hz
0.00 Hz
●