Goodrive350 series high-performance multifunction VFD
Function parameter list
-272-
Function
code
Name
Description
Default Modify
4: Deviation (Reference 100%)
5: Terminal
P90.30
Group 1
proportional gain
0.000
–30.000
0.030
○
P90.31
Group 1 integral
time
0.00
–30.00s
5.00s
○
P90.32
Group 1
differential time
0.00
–10.00s
0.00s
○
P90.33
Group 2
proportional gain
0.000
–30.000
0.030
○
P90.34
Group 2 integral
time
0.00
–30.00s
5.00s
○
P90.35
Group 2
differential time
0.00
–10.00s
0.00s
○
P90.36
PID parameter
adjustment
reference point 1
0.0%
–P90.37
10.0%
○
P90.37
PID parameter
adjustment
reference point 2
P90.36
–100.0%
50.0%
○
P90.38
Min. frequency
for roll diameter
calculation
0.00
–50.00Hz
0.30Hz
○
P90.39
Min. linear speed
for roll diameter
calculation
0.0
–100.0%
3.0%
○
P91
––
Tension control in torque mode
Function
code
Name
Description
Default Modify
P91.00
Tension control
zero speed
reference
0
–1
0: Max. linear speed
1: Max. frequency
0
◎
P91.01
Tension control
zero speed
threshold
0.0
–50.0%
3.0%
○
P91.02 Zero speed offset 0.0
–50.0%
2.0%
○
P91.03
Upper-limit
frequency source
0
–3
0: P03.14, P03.15
3
◎