GD310-UL series VFD
Basic operation instruction
-165-
Function
code
Name
Description
Default
value
1: Stop integral adjustment when the frequency
achieves the upper and low limit. If the integration
keeps stable, and the trend between the reference
and the feedback changes, the integration will
change with the trend quickly.
LED tens: P00.08 is 0
0: The same with the setting direction; if the output
of PID adjustment is different from the current
running direction, the internal will output 0 forcedly.
1: Opposite to the setting direction
LED hundreds: P00.08 is 0
0: Limit to the maximum frequency
1: Limit to frequency A
LED thousands:
0: A+B frequency, the buffer of A frequency is
invalid
1: A+B frequency, the buffer of A frequency is valid
ACC/DEC is determined by ACC time 4 of P08.04
P17.00
Setting frequency
0.00Hz
–P00.03 (the max frequency)
0.00Hz
P17.23
PID reference
-100.0
–100.0%
0.0%
P17.24
PID feedback
-100.0
–100.0%
0.0%
7.16 Traverse running
Traverse is applied in some industries such as textile, chemical fiber and cases where traverse and
convolution is required. The working flowchart is as below:
0
1
2
3
4
5
6
7
8
9
10
11
Keypad
AI1
PROFIBUS
MODBUS
PID
Multi-stage
Simple PLC
HDI
AI3
AI2
Ethernet
CAN
P00.06
(A frequency command selection)
Keypad setting frequency
P00.10
P08.05
Traverse range
*
*
Keep the current
frequency
Setting
frequency
P00.11 ACC time 1
P00.12 DEC time1
Traverse
output
Terminal function 26
Traverse pause
Terminal function 27
Traverse
Valid
Invalid
Valid
Invalid