Goodrive300-01A series VFD for air compressor
Function description
-91-
Function
code
Name
Description
Default
Modify
BIT8: Changing and discharging water to
medium water level
BIT9: Changing and replenishing water to
medium water level
BIT10: Changing and replenishing water to
high water level
BIT11: Changing and discharging water to low
water level
BIT12: Flag bit for water heating
BIT13: Flag bit for abnormal water level
BIT14: Water replenishing delay alarm
BIT15: Water discharging delay alarm
P20.08
Starting
temperature
of water
heater valve
-20
–150
℃
5
○
P20.09
Stopping
temperature
of water
heater valve
-20
–150
℃
20
○
P20.10
Alarm
temperature
of low
ambient
environment
-20
–150
℃
0
○
P21 group Power-frequency fan protection
Function
code
Name
Description
Default
Modify
P21.00
Rated current
of the fan
0.0
–40.0A
This function code is related to current
detection and overload protection function of
power-frequency fan. If P21.00 is set to a
non-zero value, this function is enabled. If
P21.00 is set to 0, this function is disabled.
0.0A
○
P21.01
Current
transformation
ratio of the fan
1.0
–4000.0
200
(
≤15kW);
1000
(
≥18.5kW)
○