Goodrive100-PV Series Solar Pumping VFD Function parameters
38
Function
code
Name
Detailed illustration of parameters
Default Modify
P07.03
QUICK/JOG the
shifting sequence
of running
command
When P07.02=6, set the shifting
sequence of running command channels.
0: Keypad control→terminal control
→communication control
1: Keypad control←→terminals control
2: Keypad control←→communication
control
3: Terminals control←→communication
control
1
○
P07.04
STOP/RST stop
function
Select the stop function by STOP/RST.
STOP/RST is effective in any state for the
keypad reset.
0: Only valid for the keypad control
1: Both valid for keypad and terminals
control
2:
Both
valid
for
keypad
and
communication control
3: Valid for all control modes
1
○
P07.11
Boost module
temperature
When the VFD is configured with the
boost module, this function code displays
the temperature of this module. This
function code is valid only in the AC mode.
This function code is invalid in the PV
mode.
-20.0–120.0°
●
P07.12
Inverter module
temperature
-20.0–120.0°
●
P07.15
MSB of VFD
Display the power used by the VFD.
●