Goodrive10 Series Mini VFD
Function parameters
-41-
Function
code
Name
Description
Default
Modify
P04.26
Energy-sa
ving
operation
0: No action
1: Automatic energy-saving operation
Under light-load state, the motor can adjust the
output voltage automatically to achieve
energy-saving purpose.
0
◎
P05 group Input terminals
Function
code
Name
Description
Default
Modify
P05.01
S1
terminal
function
selection
0: No function
1: Forward running
2: Reverse running
3: 3-wire running control
4: Forward jogging
5: Reverse jogging
6: Coast to stop
7: Fault reset
8: Running pause
9: External fault input
10: Frequency increase (UP)
11: Frequency decrease (DOWN)
12: Clear frequency increase/decrease
setting
13: Switch-over between setup A and setup B
14: Switch-over between combination setting
and setup A
15: Switch-over between combination setting
and setup B
16: Multi-step speed terminal 1
17: Multi-step speed terminal 2
18: Multi-step speed terminal 3
19: Multi-step speed terminal 4
20: Multi-step speed pause
21: ACC/DEC time selection 1
25: PID control pause
26: Wobbling frequency pause (stop at the
current frequency)
1
◎
P05.02
S2
terminal
function
selection
4
◎
P05.03
S3
terminal
function
selection
7
◎
P05.04
S4
terminal
function
selection
0
◎
P05.05
S5
terminal
function
selection
0
◎