background image

User manual 

RFID IND Modbus-Uni

Soft >= 1.3

User manual RFID IND Modbus-Uni

 

Page

 

1

 of 

15

[B03]

Содержание IND-U1

Страница 1: ...User manual RFID IND Modbus Uni Soft 1 3 User manual RFID IND Modbus Uni Page 1 of 15 B03...

Страница 2: ...e the basic principles of safety and maintenance Please also keep the user manual so that you can read it during later use Attention The manufacturer is not liable for any damage caused by improper us...

Страница 3: ...EADER 6 5 CONSTRUCTION OF THE MODULE 7 5 1 GENERAL FEATURES 7 5 2 GENERAL VIEW 8 5 3 VISUAL AND SOUND SIGNALS 8 6 DEVICE CONFIGURATION 9 6 1 OUTPUTS 10 6 2 INPUTS 11 6 3 LEDS AND SOUND SIGNALING CONTR...

Страница 4: ...could cause injury or damage to the device Important information and guidelines Following this guidelines makes the use of the device easier Attention The screenshots in this manual can be dissimilar...

Страница 5: ...comply with the contract of guarantee if the following conditions are met all repairs alterations extensions and device calibrations are performed by the manufacturer or authorized service supply netw...

Страница 6: ...ected directly to the device storage and operation at temperatures from 25 C to 60 C 4 3 Installation and use of the reader The reader should be used following the guidelines shown in next part of the...

Страница 7: ...wer supply 15mA 12V Transponders Supported transponder standard UNIQUE Manchester Carrier frequency 125kHz Reading distance up to 8cm from the directions of the device LEDs side Communication 1 RS485...

Страница 8: ...quipped with 3 LEDs indicating the module operation status and a sound generator informing about the application of the tag RFID IND Modbus Uni Name Description POWER Power LED Status 1 Error Status 2...

Страница 9: ...ect the USB cable to the computer and the module in this case the external power supply of the module is not required the device is powered via the USB port The first line of the program window displa...

Страница 10: ...tatus is engaged or disengaged Astable mode if the channel will be enabled the relay is engage and disengage cyclically Time of engage and disengage relay Time On time when a relay is engaged Time Off...

Страница 11: ...ATE INPUT 2 displays the actual state of inputs Square field in black input inactive field in yellow active input 6 3 LEDs and sound signaling control The RFID M1 U1 Configurator allows user to custom...

Страница 12: ...ill NOT appear The device will operate autonomously and automatically allow another reading of the same TAG after the declared time 6 5 RS485 Configuration of transmission The RS485 section is used to...

Страница 13: ...ag Same as Single Coil Register 1016 1001 R UID Length length of the UID 1002 1011 R UID UID number 1017 R MODEL ID ID of the device 1018 R Software Version 1019 R Hardware Version 1020 R W Mode OUT1...

Страница 14: ...1000 1017 R W ResetFlag 1 default state for power on reader It can be clear and set by user for diagnostic purpose The most frequently checked is Single Coil 1016 If its value changes to 1 it means th...

Страница 15: ...er connector 12 24VDC OUT 1 Relay output 1 OUT 2 Relay output 2 IN 1 Input 1 IN 2 Input 2 USB USB port module configuration RS485 Connector RS485 MODBUS Boot Shortening the BOOT pins when power is app...