background image

Installation and operation 

Instructions 

VMC-47VJ54 (RF-receiver) 

 
 
 
 
 
 
 
 
 
 
 
 

 
 
 
 
 

1. 

How to use this manual 

This manual is intended as a reference book by which 
qualified installers can install the VMC-47VJ54 (henceforth 
called 

“device”) and users can use the device for its intended 

purpose. Make sure you have read and understood the 
manual before you install and/or use the device. 
 

1.1  Admonitions 

Warning

’ identifies a hazard that could lead to 

personal injury, including death. 
 

Note

’ is used to highlight additional information. 

 
 

1.2 

Intended use 

The device is designed for following purposes: 
To set the speed level of ventilation through the fan speed, 
based on user input, measured humidity level, or measured 
CO

2

 level. 

Every other or further use is not in conformance with the 
intended use. 
 

1.3 

Working principle 

The device outputs a 0-10V DC signal to control a ventilation 
system. To define how the ventilation system must be 
controlled, the device receives input from one or more control 
device(s) via wireless communications. Various control 
devices are available: push button controls, humidity sensors 
and CO

2

 sensors. The device sends status information back 

to all connected control devices. 
 

1.3.1 Ventilation speeds and modes 

The ventilation system runs in one of the following modes. 

Mode 

Fan speed 

Default 

Away 

Low 

20% 

Home 

Medium 

50% 

Timer 

High for restricted 
period  

80% 

Auto 

Low-High based on 
measured values 

 

Party 

High 

100% 

The device drives the fan based on the highest of values sent 
by the bound wireless sensor(s). You can use the bound 
wireless sensor(s) to modify the configured fan speeds. 
 
 
 

2. Content delivery 

 

RF-receiver (VMC-47VJ54) 

 

1

 

 

Mounting screws 

 

2

 

 

Mounting plugs 

 

2

 

 

Manual 

 

1

 

 

3. Visual signals 

 

 

Status led 

Start up 

Orange 

Continuous 

Status 

 

 

OK 

Green 

Continuous 

Communication 
error 

RED 

1 flash 

Fan error 

 

3 flashes 

Configuration 

 

 

Binding 

Red / green 

1 flash 

 
4. Safety 

The device meets the following EC directives: 

 

EMC directive:  

2014/30/EC 

 

Low voltage directive:  2014/35/EU 

 

RTTE directive:  

2014/53/EU 

 

RoHS directive:  

2011/65/EU 

 

WEEE directive:  

2012/19/EU 

 

4.1 Signs on the device 

Check the instructions for use for important 
cautionary. 
 
 
Risk of electric shock. 
 
IEC 61140 protection Class II (double insulated). 
 
CE marking of conformity. 

 
Dispose according to European Community 
Directive 2012/19/EU (WEEE). 
 

General safety instructions 

This product was designed and manufactured to ensure 
maximum safety during installation, operation, and 
service. Always read these safety instructions before 
installing, maintaining, or servicing the product, and 
strictly comply with these instructions. Parts of the 
device carry mains power, which is a potential lethal 
voltage. Disconnect power at supply line, circuit breaker 
or fuse before installing, servicing, or removing the 
device. 
The device is designed for indoor use only. Do not 
expose the device to rain or moisture, to avoid short 
circuit. Short circuit may cause fire or electric shock 
hazard. Operate the device between 0°C and 40°C. For 
cleaning of the device use a soft damp cloth only. Never 
use any abrasive or chemical cleaner. 
 

 
 

 
 

 

A: Status-led 