20
5.3 Pipe length and the elevation
The pipe length and refrigerant amount:
Model
Pipe size
Standard
length
(m)
Max.
Elevation
B (m)
Max.
Length
A (m)
Additional
refrigerant
(g/m)
Gas
Liquid
P7MVI-
P7MVO-09
3/8’’
(
Ф9.52
)
1/4’’
(Ф6.35)
5
10
25
15
P7MVI-12WIFI
+
P7MVO-12
3/8’’
(
Ф9.52
)
1/4’’
(Ф6.35)
5
10
25
15
P7MVI-18WIFI
+
P7MVO-18
1/2
’’
(Ф
12.7)
1/4’’
(Ф6.35)
5
20
30
15
P7MVI-24WIFI
+
P7MVO-24
5
/8’’
(
Ф
15.9)
3/8’’
(
Ф9.52
)
5
25
50
30
Caution:
The capacity test is based on the standard length and the maximum permissive length is based on the
system reliability.