Страница 1: ...18 LIMO 18 LIMI 24 LIMO 24 Thank you for choosing INVENTOR air conditioning system For correct use of this unit please read this manual carefully and keep it for future reference Wall Mounted Unit Ow...
Страница 2: ...ection of installation location 24 Requirements for electric connection 25 Installation Installation of indoor unit 26 Installation of outdoor unit 31 Vacuum pumping 35 Leakage detection 35 Check afte...
Страница 3: ...t if not avoided could result in death or serious injury Indicates a hazardous situation that if not avoided may result in minor or moderate injury Indicates important but not hazard related informati...
Страница 4: ...appliance Cleaning and user maintenance shall not be made by children without supervision years and above and persons with reduced physical sensory or mental capabilities or lack of experience and kno...
Страница 5: ...amage Precautions WARNING conditioner and disconnect power immediately and then If the air conditioner operates under abnormal conditions it may cause malfunction electric shock or fire hazard Do not...
Страница 6: ...les before using the air conditioner An all pole disconnection switch having a contact separation Must follow the electric safety regulations when installing the unit grounding wire of power socket Pr...
Страница 7: ...nnected by a professional national wiring regulations requirement of NEC and CEC by authorized personnel only Precautions WARNING wire which can t be used for other purposes The grounding resistance s...
Страница 8: ...the line For the air conditioner without plug an circuit break far away from animals or plants If it is unavoidable please add the fence for safety purpose Select a location which is out of reach for...
Страница 9: ...lease refer to actual products Parts Name Indoor Unit Outdoor Unit air inlet panel aux button horizontal louver air outlet remote control air inlet Connection wire air outlet NOTICE Actual product may...
Страница 10: ...r display For some model For some model For some model For some model heating indicator temp indicator cooling indicator power indicator receiver window drying indicator display G W R Power LED color...
Страница 11: ...TIMER OFF button SLEEP button button Send signal Turbo mode 8 heating function Set temperature Set time TIMER ON TIMER OFF Child lock Up down swing Set fan speed Light Temp display type Set temp Outdo...
Страница 12: ...l give out a sound Operation indictor is ON red indicator After that you can operate the air conditioner by using remote controller Under on status pressing the button on the remote controller the sig...
Страница 13: ...ton above 2s to set your required swing angle When reaching your required angle release the button Note may not be available When air conditioner receives this signal the air conditioner will blow fan...
Страница 14: ...ing with remote controller temperature indicator on indoor unit displays outdoor ambient temperature Note Outdoor temperature display is not available for some models At that time indoor unit receives...
Страница 15: ...utton to start I FEEL function and will be displayed on the remote controller After this function is set the remote controller will send the detected ambient temperature to the controller and the unit...
Страница 16: ...ease or decrease 1min Hold or button 2s later the time will change quickly until reaching your required time resumes displaying Cancel TIMER ON Under the condition that TIMER ON is started up press TI...
Страница 17: ...emote controller won t send signal Sleep function and 8 heating function can t operate at the same time If 8 heating function has been set under cooling mode press sleep button will cancel 8 heating f...
Страница 18: ...tion 2 Replace two 7 AAA 1 5V dry batteries and make sure the position of polar and polar are correct 3 Reinstall the cover of battery box signal sender battery Cover of battery box remove reinstall D...
Страница 19: ...conditioner The operation in details are as below 16 Clean and maintenance Turn off the air conditioner and disconnect the power before cleaning the air conditioner to avoid electric shock Do not was...
Страница 20: ...panel Pull out the panel to a certain Use dust catcher or water to the water below 45 to clean it and then put it in a shady and cool place to dry panel cover tightly operation environment clean freq...
Страница 21: ...pipe is damaged 1 Disconnect power supply 3 Check whether mounting bracket for outdoor unit is damaged or corroded If yes please contact dealer Notice for recovery 1 Many packing materials are recycl...
Страница 22: ...sert the plug after about 3min and then turn on the unit again Signal receiving range is 8m Remove obstacles Select proper angle and point the remote controller at the re ceiving window on indoor unit...
Страница 23: ...Indoor temperature and hum idity is high Because indoor air is cooled rapidly After a while indoor temperature and humidity will be decrease and mist will disappear Phenomenon Check items Solution Se...
Страница 24: ...Heating mode is turned on During defrosting under he ating mode it may generate vapor which is a normal phenomenon Water noise Air conditioner is turned on or turned off just now The noise is the soun...
Страница 25: ...w phenomenon occurs please turn off air conditioner and discon for service Power cord is overheating or damaged There s abnormal sound during operation Air switch trips off frequently Air conditioner...
Страница 26: ...east 50cm At least 30cm At least 300cm At least 200cm Space to the obstruction Space to the obstruction Space to the obstruction Space to the ceiling Space to the obstruction Space to the obstruction...
Страница 27: ...e near coast area 4 The place with oil or fumes in the air 5 The place with sulfureted gas 6 Other places with special circums tances 7 The appliance shall nost be install ed in the laundry will not a...
Страница 28: ...y from the copper tube 9 The appliance shall be installed in accordance with national wiring regulations grounding with specialized grounding device by a professional Please make sure it is always gro...
Страница 29: ...ing hole 18K 12K 07K 2 Open a piping hole with the diameter of 55 or 70 on the selected outlet pipe position In order to drain smoothly slant the piping hole on the wall slightly downward to the outdo...
Страница 30: ...ng out the pipe from left or right please cut off the corresponding hole on the bottom case cut off the hole left right 1 The pipe can be led out in the direction of right rear right left or rear left...
Страница 31: ...in the indoor drain hose in order to prevent condensation The plastic expansion particles are 1 Open the panel remove the screw on the wiring cover and then take down the cover wiring cover screw pane...
Страница 32: ...n N 1 2 4 5 blue violet orange black yellow green Outdoor unit connection 07 09 12 18K Heat pump type N 1 2 blue black yellow green Outdoor unit connection 07 09 12 18K Cool only type 18 24K Cool only...
Страница 33: ...parately at the end Note The power cord and control wire can t be crossed or winding The drain hose should be bound at the bottom drain hose band connection pipe indoor power cord Step nine hang the i...
Страница 34: ...For the unit with cooling capacity of 2300W 5000W 6 expansion screws are needed for the unit with cooling capacity of 6000W 8000W 8 expansion screws are needed for the unit with cooling capacity of 10...
Страница 35: ...emove the screw cap of valve and aim the pipe joint at the bellmouth of pipe 3 Pretightening the union nut with hand 4 Tighten the union nut with torque wrench by referring to the sheet below handle s...
Страница 36: ...1 2 blue black yellow green 3 brown 1 Remove the wire clip connect the power connection wire and signal control wire only for cooling and heating unit to the wiring terminal according to the color fix...
Страница 37: ...e outlet pipe hole of indoor unit Slant the drain hose slightly dow nwards The drain hose can t be The water outlet can t be placed in water in order to drain smoothly Installation of outdoor unit U s...
Страница 38: ...If the pressure decreases there may be leakage 5 Remove the piezometer open the valve core of liquid valve and gas valve completely with inner hexagon spanner 6 Tighten the screw caps of valves and re...
Страница 39: ...r damaging the parts Is there any obstruction in the air inlet Is the inlet and outlet of piping hole been covered and outlet heating capacity The dust and sundries caused during installation are remo...
Страница 40: ...l refrigerant charging amount per meter is different according to the diameter of liquid pipe See the following sheet Additional refrigerant charging amount prolonged length of liquid pipe additional...
Страница 41: ...Diameter of connection pipe Liquid pipe mm Gas pipe mm 6 6 or 9 52 12 16 19 22 2 9 52 or 12 16 or 19 19 or 22 2 25 4 or 31 8 _ _ Cooling only g m Cooling and heating g m 15 15 30 60 250 250 350 350 12...
Страница 42: ...from getting into the pipe downwards pipe shaper C Put on suitable insulating pipe D Put on the union nut Remove the union nut on the indoor connection pipe and outdoor valve install the union nut on...