background image

 
 

Hardware  Operations 

 

20 

 

2.5  System Memory 

The motherboard supports 16 DDR3 DIMM slots, including Registered DIMMs (RDIMM), 

Load Reduced DIMMs (LRDIMM) and Unbuffered DIMMs (UDIMM). There are four DIMM 

channels per CPU, and 2 DIMM slots per channel. Data transfer rates can support DDR3 

800/1066/1333/1600. 

The location of DIMM sockets on the motherboard is shown below: 

 

Figure 2-8    Location of System Memories 

 

There are sixteen DIMMs on the motherboard to support the processor. The DIMM 

sequence of sixteen DIMM sockets is respectively shown below. 

 

Содержание B800

Страница 1: ...About This Manual i Board B800 May 2012 Revision A 1 ...

Страница 2: ... in Taiwan United States and other countries Disclaimer This manual provides the information in relation to the set up and installation of the product herein Nothing herein may be construed as granting any right or license relating to any intellectual property rights of this manual or product Unless otherwise provided in the Purchase and Sale Agreement for this product manufacturer and distributor...

Страница 3: ...About This Manual iii ...

Страница 4: ...Organization 1 1 3 Product Features 2 1 4 Boards Layout 4 1 5 System LED and Button Information 7 1 5 1 LED and Button Information of Motherboard Rear 7 2 Hardware Operations 10 2 1 Before You Start 10 2 2 Screw Holes 11 2 2 1 Motherboard Screw Holes 11 2 3 System Battery 13 2 3 1 To remove and install the system battery 14 2 4 Processor 15 2 4 1 To remove the heat sink 16 2 4 2 To install the hea...

Страница 5: ... Connectors J28 J29 50 3 12 NIC LAN and USB Ports J95 J21 52 3 12 1 Dedicate NIC and Rear USB Connector J95 52 3 12 2 Gbe NIC LAN port J21 53 3 13 COM and VGA Ports J92 55 4 BIOS Setup 58 4 1 BIOS Setup Utility 59 4 1 1 Main 59 4 1 2 Advanced 60 4 1 3 Boot 84 4 1 4 Security 87 4 1 5 Save Exit 88 4 1 6 Event Logs 89 4 1 7 Server Mgmt 90 4 2 Utility and POST Code 94 4 2 1 BIOS Requirements 94 4 2 2 ...

Страница 6: ...3 14 Gbe NIC Ports 53 Figure 3 15 VGA and COM Ports 55 Appendix Figure I China RoHS Regulations I List of Tables Table 1 1 Manual Introduction 1 Table 1 2 Product SKUs 2 Table 1 3 Product Features 3 Table 1 4 Connectors and Component Locations of Motherboard 4 Table 1 5 LED Information 7 Table 2 1 Function of Function Jumpers 30 Table 3 1 Pin Definition of Power Management Connector J98 32 Table 3...

Страница 7: ...n Definition of SATA Connectors J44 41 Table 3 24 Pin Definition of SATA Connectors J45 41 Table 3 25 Pin Definition of SGPIO Connector J46 42 Table 3 26 Pin Definition of Mini SAS Connectors J104 43 Table 3 27 Pin Definition of Mini SAS Connectors J105 for Patsburg D SKU 44 Table 3 28 Pin Definition of Front Panel Connector J90 45 Table 3 29 Pin Definition of Front USB Connector J17 46 Table 3 30...

Страница 8: ...About This Manual i Conventions Safety Symbols Safety Precautions Regulatory and Integration Information About This Manual ...

Страница 9: ...bols used throughout this manual Warning Information to prevent injury to yourself when trying to complete a task Caution Information to prevent damage to the components when trying to complete a task Important Information that you must follow to complete a task Note Tips and information to aid in completing a task ...

Страница 10: ... risk of injury from electric shock hazards do not open this enclosure Indicates the presence of a hot surface or hot component Warning To reduce the risk of injury from a hot component allow the surface to cool before touching it Any RJ45 receptacle marked with this symbol indicates a network interface connection Warning To reduce the risk of electric shock fire or damage to the equipment Do not ...

Страница 11: ...ening the chassis panels make sure all power cords are unplugged Avoid dust humidity and extreme temperatures place the server on a stable surface If the power supply is broken do not try to fix it by yourself Contact an authorized dealer It is recommended that you wear gloves when assembling or disassembling the server to protect from cuts and scrapes When the server is powered on heat sinks and ...

Страница 12: ...or pins If you need to lay the device down while it is out of the antistatic bag Lay it on the antistatic bag Before picking it up again touch the antistatic bag and the metal frame of the system unit at the same time Handle the devices carefully to prevent permanent damage Battery Replacement Safety This server is provided with an internal Lithium battery or battery pack There is a danger of expl...

Страница 13: ... equipment other than an ITE application may require further evaluation Site Selection The system is designed to operate in a typical office environment Choose a site that is Clean dry and free of airborne particles other than normal room dust Well ventilated and away from sources of heat including direct sunlight and radiators Away from sources of vibration or physical shock Isolated from strong ...

Страница 14: ...chnology Equipment UL 94 Tests for Flammability of Plastic Materials for Parts in Devices Appliances Product EMC Compliance This product has been tested and verified to comply with the following electromagnetic compatibility EMC regulations Communications Commission Notice Part 15 of the Federal Communications Commission FCC Rules and Regulations has established Radio Frequency RF emission limits ...

Страница 15: ...s Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at personal expense Declaration of Conformity for Products Marked with the FCC Logo United States Only This device complies with Part 15 of the FCC Rules Operation and is subject to the following two conditions 1 this device may not cause h...

Страница 16: ...viii Canadian Notice Avis Canadien Class A Equipment Japanese Notice Taiwanese Notice ...

Страница 17: ...Audience Assumptions Manual Organization Product Features Boards Layout System LED Information Chapter 1 Introduction ...

Страница 18: ...along with the hardware information and how to replace the hardware This manual is generally organized as follows Table 1 1 Manual Introduction Introduction General motherboard introduction and LED information Hardware Operations The operation of the components on the motherboard such as system battery processor system memory and so forth Connectors Jumper and Switch Necessary information such as ...

Страница 19: ...n as the following table Table 1 2 Product SKUs PCBA PN SKU SKU PCH AST2300 BOM DEPOP ID 2 0 Attribute 1395A2491601 10G_SP 0 0 1 Patsburg A V CN N6 1395A2491602 10G_DP 0 1 0 Patsburg A V CN N2 1395A2491603 10G_SP 1 0 1 Patsburg D V CN N5 1395A2491604 GBE 1 1 0 Patsburg A V CN N4 1395A2491605 GBE 10G_SP 1 0 0 Patsburg A V CN N3 This motherboard supports Intel Sandy Bridge EP CPU with integrated mem...

Страница 20: ...Dual Channel Gbe Controller Intel Powerville i350 AM2 for Gbe SKU Onboard Storage port Four SATA 3Gbs ports Two SATA 6Gbs ports Four SATA 6Gbs ports Patsburg A from SCU Eight SATA SAS 6Gbs ports Patsburg D from SCU Fan control PWM fan speed control Fourteen Fan connectors Seven of these are optiona Media Bays and Ports Two front USB connectors Two rear USB connectors Two inner USB connectors Optio...

Страница 21: ...w Each connector and major component is identified by number Figure 1 2 Connectors and Component Locations of Motherboard Table 1 4 Connectors and Component Locations of Motherboard 1 DIMM slots J13 J14 J15 J16 2 Power Management connector J98 3 Power Connector J89 ...

Страница 22: ...r J106 15 Mini SAS connector J105 for 10Gbe with Patsburg D SKU 16 Intruder Header J53 17 Mini SAS connector J104 18 BIOS recovery Jumper J22 19 Thermal sensor BP connector J59 20 Front Panel connector J90 21 P12VB power connector J20 22 Front USB Connector J17 23 CMOS Clear Jumper J52 24 Password Clear Jumper J49 25 PCI E Slot 2 X 8 J80 26 Battery BH2 27 SFP Connector Cage 1 J28 J31 Optional for ...

Страница 23: ...31 PCI E Slot 6 X 16 J64 32 DIMM slots J9 J10 J11 J12 33 UID BTN LED CR42 34 CPU 1 U1 35 Gbe NIC1 2 up down ports J21 for Gbe SKU 36 Dedicate NIC up and Rear USB down J95 37 COM up VGA down connector J92 ...

Страница 24: ...D 3 Gbe Link Activity LED NIC2 for Gbe SKU 4 Gbe Link Activity LED NIC1 for Gbe SKU 5 Gbe Speed LED NIC1 for Gbe SKU 6 Gbe Speed LED NIC2 for Gbe SKU 7 UID Button LED 8 10Gbe LINK ACT LED NIC1 for 10Gbe SKU 9 10Gbe SPEED LED NIC1 for 10Gbe SKU 10 10Gbe LINK ACT LED NIC2 Optional for 10Gbe SKU 11 10Gbe SPEED LED NIC2 Optional for 10Gbe SKU The detailed LED information is shown below Table 1 5 LED I...

Страница 25: ...d to the network at 1Gbps Off Linked to the network at 10Mbps UID Blue On Identification Blue Blink System is being remotely Off Idle 10Gbe NIC1 Link Activity Green On LAN link No access Green Blink LAN link Access Off No connection 10Gbe Speed Green On Linked to the network at 10Gbps Amber On Linked to the network at 1Gbps Off Linked to the network at 100Mbps 10Gbe NIC2 Link Activity Green On LAN...

Страница 26: ...9 Before You Start Screw Holes System Battery Processor System Memory System Configuration Jumpers Chapter 2 Hardware Operations ...

Страница 27: ... the server is not turned on or connected to the AC power Step 2 Remove the chassis cover Moving the Power On Off switch to the Off position does not completely remove system power Some portions of the power supply and some internal circuitry remain active Disconnect all power cords from the server to remove all power from the system The components shown in this chapter are mainly for your referen...

Страница 28: ...les 2 2 1 Motherboard Screw Holes The motherboard is designed with totally nine screw holes as the picture shows Figure 2 1 Screws Placement of Motherboards Screw Hole Do not overly tighten the screws Doing so may damage the motherboard ...

Страница 29: ...Hardware Operations 12 ...

Страница 30: ...Hardware Operations 13 2 3 System Battery The location of system battery is shown below Figure 2 2 System Battery Location ...

Страница 31: ...ry up To install the system battery slide one edge of the battery under the holder s lip with the positive side up Push the other edge down until the clamp snaps over the other edge of the battery Figure 2 1 Remove and Install the System Battery Do not bend the retaining clip during system battery replacement For proper operation the clip must maintain a position of contact with the system battery...

Страница 32: ...his motherboard supports one Intel Sandy Bridge DT processor Below set removing and installing heat sink and processor of motherboard The location of processors on the motherboard is shown below Figure 2 2 Location of Processors 1 Processor ...

Страница 33: ...at sink up from the installed processor Figure 2 3 Remove Heat Sink 2 4 2 To install the heat sink Reverse the steps above to install the heat sink Before you put the heat sink on top of the installed processor please do not forget to check if the grease is complete on bottom of the heat sink ...

Страница 34: ...ions 17 2 4 3 To remove the processor Unlock the load lever and lift it up Open the load plate Figure 2 4 Opening the Load Plate Lift the processor out of the socket Figure 2 5 Lifting the Processor out of the Socket ...

Страница 35: ...he socket make sure that the golden corner on the processor is pointed toward the socket as picture shows Figure 2 7 Pointing the Golden Corner toward the Socket When the processor is in place press it firmly on the socket while you push down the socket lever to secure the processor The lever clicks on the socket indicating that it is locked The processor fits only in one orientation Do not force ...

Страница 36: ...Hardware Operations 19 socket to avoid bending the pins and damaging the processor If the processor does not fit completely check its orientation or check for bent pins ...

Страница 37: ...UDIMM There are four DIMM channels per CPU and 2 DIMM slots per channel Data transfer rates can support DDR3 800 1066 1333 1600 The location of DIMM sockets on the motherboard is shown below Figure 2 8 Location of System Memories There are sixteen DIMMs on the motherboard to support the processor The DIMM sequence of sixteen DIMM sockets is respectively shown below ...

Страница 38: ...Hardware Operations 21 Figure 2 9 DIMM Socket Location ...

Страница 39: ...All channels must run at the same interface frequency but individual channels may run at different DIMM timings RAS latency CAS latency and so forth Rank Sparing Mode In Rank Sparing Mode one rank is a spare of the other ranks on the same channel The spare rank is held in reserve and is not available as system memory The spare rank must have identical or larger memory capacity than all the other r...

Страница 40: ...hannel 3 must be populated identically with regards to size and organization DIMM slot populations within a channel do not have to be identical but the same DIMM slot location across Channel 0 and Channel 1 and across Channel 2 and Channel 3 must be populated the same ...

Страница 41: ... that all designs follow the DIMM ordering command clock and control signal routing documented in below figure This addressing must be maintained to be compliant with the reference BIOS code supplied by Intel All allowed DIMM population configurations for two slots per channel are shown in below tables When one DIMM is used it must be populated in DIMM slot0 farthest away from the CPU of a given c...

Страница 42: ...Hardware Operations 25 DDR3 RDIMM Population DDR3 UDIMM Population DDR3 LRDIMM Population ...

Страница 43: ...Hardware Operations 26 DDR3L RDIMM Population 1 35V DDR3L UDIMM Population 1 35V ...

Страница 44: ...Hardware Operations 27 ...

Страница 45: ...it out of the socket Lift out the DIMM Figure 2 12 Lifting the DIMM out of the Socket 2 5 3 To install a DIMM Unlock a DIMM socket by pressing the retaining clips outward Figure 2 13 Pressing the Retaining Clips Outward Align the notch on the DIMM to the break on the socket Carefully insert the DIMM into the socket until the retaining clips snap back in place ...

Страница 46: ...Hardware Operations 29 Figure 2 14 Inserting the DIMM into the Socket DIMMs fit in only one direction DO NOT force a DIMM into the socket to avoid damaging the DIMM ...

Страница 47: ...he motherboard involves one function jumper The jumper is divided into seven pin groups Figure 2 15 Location of Function Jumpers Table 2 1 Function of Function Jumpers Jumper Function A BIOS Recovery Jumper B Intruder header C BIOS CMOS Clear D Password Clear ...

Страница 48: ...ctor Fan Connectors P12V Power Connector SATA Connectors SGPIO Connector Chapter 3 Connectors Jumpers and Switches Mini SAS Connectors Front Panel connector Front USB Connector PCI E Slots SFP Connectors NIC LAN and USB Ports COM and VGA Ports ...

Страница 49: ...1 4 Connectors and Component Locations Key stands for foolproof feature NC stands for unused 3 1 Power Management Connector J98 Figure 3 1 Power Management Connector Table 3 1 Pin Definition of Power Management Connector J98 Pin Signal Name 1 I2C_PSU_SCL 2 I2C_PSU_SDA 3 I2C_PSU_ALERT_R_N 4 Ground 5 P3V3SB_I2C_PSU ...

Страница 50: ...ition of Power Connector J89 Signal Name Pin Pin Signal Name P3V3 1 13 P3V3 P3V3 2 14 N12V Ground 3 15 Ground P5V 4 16 PS_EN_PSU_N Ground 5 17 Ground P5V 6 18 Ground Ground 7 19 Ground PGD_PSU_PWROK_5V 8 20 NC P5V_AUX 9 21 P5V P12V 10 22 P5V P12V 11 23 P5V P3V3 12 24 Ground ...

Страница 51: ...in Signal Name 1 BMC_FAN_PWM_1_R 2 BMC_FAN_TACH_1_R 3 P12VA 4 Ground Table 3 4 Pin Definition of Fan Connector J107 Optional Pin Signal Name 1 BMC_FAN_PWM_8_R 2 BMC_FAN_TACH_8_R 3 P12VA 4 Ground Table 3 5 Pin Definition of Fan Connector J108 Pin Signal Name 1 BMC_FAN_TACH_2_R 2 BMC_FAN_PWM_2_R 3 P12VA 4 Ground Table 3 6 Pin Definition of Fan Connector J109 Optional ...

Страница 52: ...110 Pin Signal Name 1 BMC_FAN_PWM_3_R 2 BMC_FAN_TACH_3_R 3 P12VA 4 Ground Table 3 8 Pin Definition of Fan Connector J111 Optional Pin Signal Name 1 BMC_FAN_PWM_10_R 2 BMC_FAN_TACH_10_R 3 P12VA 4 Ground Table 3 9 Pin Definition of Fan Connector J112 Pin Signal Name 1 BMC_FAN_PWM_4_R 2 BMC_FAN_TACH_4_R 3 P12VA 4 Ground ...

Страница 53: ...in Definition of Fan Connector J115 Optional Pin Signal Name 1 BMC_FAN_PWM_12_R 2 BMC_FAN_TACH_12_R 3 P12VA 4 Ground Table 3 13 Pin Definition of Fan Connector J116 Pin Signal Name 1 BMC_FAN_PWM_6_R 2 BMC_FAN_TACH_6_R 3 P12VA 4 Ground Table 3 14 Pin Definition of Fan Connector J117 Optional Pin Signal Name 1 BMC_FAN_PWM_13_R 2 BMC_FAN_TACH_13_R 3 P12VA 4 Ground Table 3 15 Pin Definition of Fan Con...

Страница 54: ...37 Pin Signal Name 3 P12VA 4 Ground Table 3 16 Pin Definition of Fan Connector J119 Optional Pin Signal Name 1 BMC_FAN_PWM_14_R 2 BMC_FAN_TACH_14_R 3 P12VA 4 Ground ...

Страница 55: ...nition of P12VA Power Connector J88 Signal Name Pin Pin Signal Name Ground 1 5 P12VA Ground 2 6 P12VA Ground 3 7 P12VA Ground 4 8 P12VA Table 3 18 Pin Definition of P12VB Power Connector J20 Signal Name Pin Pin Signal Name Ground 1 5 P12VB Ground 2 6 P12VB Ground 3 7 P12VB Ground 4 8 P12VB ...

Страница 56: ...nnectors J40 Pin Signal Name 1 Ground 2 SATA_TX1_C_DP 3 SATA_TX1_C_DN 4 Ground 5 SATA_RX1_C_DN 6 SATA_RX1_C_DP 7 Ground 8 Ground 9 Ground Table 3 20 Pin Definition of SATA Connectors J41 Pin Signal Name 1 Ground 2 SATA_TX0_C_DP 3 SATA_TX0_C_DN 4 Ground 5 SATA_RX0_C_DN 6 SATA_RX0_C_DP 7 Ground 8 Ground 9 Ground ...

Страница 57: ...nd 2 SATA_TX3_C_DP 3 SATA_TX3_C_DN 4 Ground 5 SATA_RX3_C_DN 6 SATA_RX3_C_DP 7 Ground 8 Ground 9 Ground Table 3 22 Pin Definition of SATA Connectors J43 Pin Signal Name 1 Ground 2 SATA_TX2_C_DP 3 SATA_TX2_C_DN 4 Ground 5 SATA_RX2_C_DN 6 SATA_RX2_C_DP 7 Ground 8 Ground 9 Ground ...

Страница 58: ...nd 2 SATA_TX5_C_DP 3 SATA_TX5_C_DN 4 Ground 5 SATA_RX5_C_DN 6 SATA_RX5_C_DP 7 Ground 8 Ground 9 Ground Table 3 24 Pin Definition of SATA Connectors J45 Pin Signal Name 1 Ground 2 SATA_TX4_C_DP 3 SATA_TX4_C_DN 4 Ground 5 SATA_RX4_C_DN 6 SATA_RX4_C_DP 7 Ground 8 Ground 9 Ground ...

Страница 59: ...42 3 6 SGPIO Connector J46 Figure 3 6 SGPIO Connector Table 3 25 Pin Definition of SGPIO Connector J46 Pin Signal Name 1 SGPIO_SATA_CLK 2 SGPIO_SATA_LOAD 3 SGPIO_SATA_DOUT0 4 SGPIO_SATA_DOUT1 ...

Страница 60: ...P 2 SAS_PCH_TX_C_DP 1 B5 A5 SAS_PCH_RX_C_DP 1 SAS_PCH_TX_C_DN 1 B6 A6 SAS_PCH_RX_C_DP 1 SAS_PCH_TX_C_DP 0 B2 A2 SAS_PCH_RX_C_DP 0 SAS_PCH_TX_C_DN 0 B3 A3 SAS_PCH_RX_C_DP 0 TP_PCH_SAS1_SIDEBAND6 B11 A11 SGPIO_SAS1_DATAIN_F Ground B10 A10 SGPIO_SAS1_DATAOUT_F SGPIO_SAS1_LOAD_F B9 A9 Ground SGPIO_SAS1_CLOCK_F B8 A8 TP_PCH_SAS1_SIDEBAND7 Ground B1 A1 Ground Ground B4 A4 Ground Ground B7 A7 Ground Grou...

Страница 61: ..._PCH_TX_C_DP 5 B5 A5 SAS_PCH_RX_C_DP 5 SAS_PCH_TX_C_DN 5 B6 A6 SAS_PCH_RX_C_DN 5 SAS_PCH_TX_C_DP 4 B2 A2 SAS_PCH_RX_C_DP 4 SAS_PCH_TX_C_DN 4 B3 A3 SAS_PCH_RX_C_DN 4 TP_PCH_SAS2_SIDEBAND6 B11 A11 SGPIO_SAS2_DATAIN_F Ground B10 A10 SGPIO_SAS2_DATAOUT_F SGPIO_SAS2_LOAD_F B9 A9 Ground SGPIO_SAS2_CLOCK_F B8 A8 TP_PCH_SAS2_SIDEBAND7 Ground B1 A1 Ground Ground B4 A4 Ground Ground B7 A7 Ground Ground B12 ...

Страница 62: ... 1 2 P3V3_STBY 4 P5V_STBY LED_PWR_GRN_N 5 6 BMC_UID_LED_R_N P3V3 7 8 FP_HLTH_GRN_LED_N LED_HDD_ACT_R_N 9 10 FP_HLTH_RED_LED_N BTN_FP_PWR_N 11 12 P3V3_STBY Ground 13 14 LED_NIC1_LINK_ACT_R_N BTN_FP_RST_N 15 16 I2C_SDA_SENS_FP_BUF Ground 17 18 I2C_SCL_SENS_FP_BUF BTN_UID_N 19 20 INTRUDER_N LED_PWR_AMBER_R_N 21 22 P3V3_STBY BTN_FP_NMI_N 23 24 LED_NIC2_LINK_ACT_R_N ...

Страница 63: ...r J17 Figure 3 9 Front USB Connector Table 3 29 Pin Definition of Front USB Connector J17 Signal Name Pin Pin Signal Name P5V_USB89 1 2 P5V_USB89 USB8_SB_L_DN 3 4 USB9_SB_L_DN USB8_SB_L_DP 5 6 USB9_SB_L_DP Ground 7 8 Ground 10 ...

Страница 64: ...Slot J64 Signal Name Pin Pin Signal Name P12VB A2 A9 P3V3 P12VB A3 A10 P3V3 P12VB B1 B8 P3V3 P12VB B2 B10 P3V3_STBY P12VB B3 A4 Ground Ground B4 A12 Ground Ground B7 A15 Ground Ground B13 A18 Ground Ground B16 A20 Ground Ground B18 A23 Ground Ground B21 A24 Ground Ground B22 A27 Ground Ground B25 A28 Ground Ground B26 A31 Ground Ground B29 A34 Ground Ground B32 A37 Ground Ground B35 A38 Ground ...

Страница 65: ...Ground B56 A58 Ground Ground B57 A59 Ground Ground B60 A62 Ground Ground B61 A63 Ground Ground B64 A66 Ground Ground B65 A67 Ground Ground B68 A70 Ground Ground B69 A71 Ground Ground B72 A74 Ground Ground B73 A75 Ground Ground B76 A78 Ground Ground B77 A79 Ground Ground B80 A82 Ground 3 10 2 PCI Ex8 Slot J80 Figure 3 11 PCI Ex8 Slot Table 3 31 Pin Definition of PCI Ex8 Slot J80 Signal Name Pin Pin...

Страница 66: ...CPU0_SLOT2_RX_DN 7 0 PE3_CPU0_SLOT2_TX_DN 7 0 B20 A22 PE3_CPU0_SLOT2_RX_DN 7 0 PE3_CPU0_SLOT2_TX_DN 7 0 B24 A26 PE3_CPU0_SLOT2_RX_DN 7 0 PE3_CPU0_SLOT2_TX_DN 7 0 B28 A30 PE3_CPU0_SLOT2_RX_DN 7 0 PE3_CPU0_SLOT2_TX_DN 7 0 B34 A36 PE3_CPU0_SLOT2_RX_DN 7 0 PE3_CPU0_SLOT2_TX_DN 7 0 B38 A40 PE3_CPU0_SLOT2_RX_DN 7 0 PE3_CPU0_SLOT2_TX_DN 7 0 B42 A44 PE3_CPU0_SLOT2_RX_DN 7 0 PE3_CPU0_SLOT2_TX_DN 7 0 B46 A4...

Страница 67: ...round I2C_NIC_SCL_P1_R 5 16 P3V3_SFP1 SPF_SPD1_2_MOD_ABS 6 15 P3V3_SFP1 NIANTIC_SPD1_6_RS0 1_SENSE 7 14 Ground NIANTIC_SPD1_0_RX_LOS 8 13 NIANTIC_RX_P1_L0_DP NIANTIC_SPD1_6_RS0 1_SENSE 9 12 NIANTIC_RX_P1_L0_DN Ground 10 11 Ground Table 3 33 Pin Definition of SFP connector J29 Signal Name Pin Pin Signal Name Ground 1 20 Ground NIANTIC_SPD0_7_TX_FAULT 2 19 NIANTIC_TX_P0_L0_DN NIANTIC_SPD0_3_TX_DISAB...

Страница 68: ...51 Signal Name Pin Pin Signal Name NIANTIC_SPD0_0_RX_LOS 8 13 NIANTIC_RX_P0_L0_DP NIANTIC_SPD0_6_RS0 1_SENSE 9 12 NIANTIC_RX_P0_L0_DN Ground 10 11 Ground ...

Страница 69: ...or Table 3 34 Pin Definition of Dedicate NIC and Rear USB Connector J95 Pin Signal Name 1 P5V_USB1011 2 USB10_SB_L_DN 3 USB10_SB_L_DP 4 Ground 5 P5V_USB1011 6 USB11_SB_L_DN 7 USB11_SB_L_DP 8 Ground 9 P2V5_PHY_AVDD 10 BCM5221_MDI_TX_DP 11 BCM5221_MDI_TX_DN 12 BCM5221_MDI_RX_DP 13 BCM5221_MDI_RX_DN 14 NC 15 NC 16 NC 17 NC 18 Ground ...

Страница 70: ...U Figure 3 14 Gbe NIC Ports Table 3 35 Pin Definition of Gbe NIC Ports J21 for Gbe SKU Pin Signal Name 1 NIC2_MDI_0_DN 2 NIC2_MDI_0_DP 3 NIC2_MDI_1_DN 4 NIC2_MDI_1_DP 5 NIC2_MDI_2_DN 6 NIC2_MDI_2_DP 7 NIC2_MDI_3_DN 8 NIC2_MDI_3_DP 9 P1V8_STBY 10 Ground 11 NIC1_MDI_0_DN 12 NIC1_MDI_0_DP 13 NIC1_MDI_1_DN 14 NIC1_MDI_1_DP 15 NIC1_MDI_2_DN 16 NIC1_MDI_2_DP ...

Страница 71: ...1_MDI_3_DN 18 NIC1_MDI_3_DP 19 P1VB_STBY 20 Ground 21 NIC2_1000M_ORG_N 22 NIC2_100M_GRN_N 23 NIC2_ACT_N 24 NIC2_LINK_N 25 NIC1_1000M_ORG_N 26 NIC1_100M_ORG_N 27 NIC1_ACT_N 28 NIC1_LINK_N 29 Ground 30 Ground 31 Ground 32 Ground ...

Страница 72: ...me 1 COM1_RES_DCD 2 COM1_RES_RX_N 3 COM1_RES_TX_N 4 COM1_RES_DTR 5 Ground 6 COM1_RES_DSR 7 COM1_RES_RTS 8 COM1_RES_CTS 9 COM1_RES_RI Table 3 37 Pin Definition of VGA Down Port J92 Pin Signal Name P1 VGA_G0_RED_L P2 VGA_G0_GREEN_L P3 VGA_G0_BLUE_L P4 NC P5 Ground P6 Ground P7 Ground P8 Ground P9 P5V_VGA_CNTR P10 Ground ...

Страница 73: ...56 Pin Signal Name P11 NC P12 VGA_DDCDAT_R P13 VGA_HSYNC_LSHFTR_L P14 VGA_VSYNC_LSHFTR_L P15 VGA_DDCCLK_R ...

Страница 74: ...57 BIOS Setup Utility Utility and POST Code Chapter 4 BIOS Setup ...

Страница 75: ...accomplished by the BIOS POST routines and the BIOS Plug N Play auto configuration manager The configuration utilities update a checksum for both areas so potential data corruption is detected by the BIOS before the hardware configuration is saved If the data is corrupted the BIOS requests that the user reconfigure the system and reboot Because the BIOS code is the most often changed part of the m...

Страница 76: ... System Data System Time Access Level American Megatrends 4 6 4 1 UEFI 2 1 PI 0 9 800G xx xx x64 xx xx xxxx xx xx xx 2048 MB DDR3 Sat 01 01 2005 00 00 00 Administrator Set the Data Time Use Tab to switch between Data Time elements Select Screen Select Item Enter Select Change Opt F1 General Help F2 Previous Values F3 Optimized Defaults F4 Save Exit ESC Exit Version 2 02 1205 Copyright 2010 America...

Страница 77: ... ME Subsystem Memory Configuration Onboard Device Configuration Serial Port Console Redirection iSCSI Disabled Power off Select Screen Select Item Enter Select Change Opt F1 General Help F2 Previous Values F3 Optimized Defaults F4 Save Exit ESC Exit Version 2 02 1205 Copyright 2010 American Megatrends Inc Menu Fields Settings Comments Advanced Restore AC power Loss Pwer off Power on Last state Spe...

Страница 78: ... 02 1205 Copyright 2010 American Megatrends Inc Menu Fields Settings Comments Advanced Trusted Computing TPM SUPPORT Disabled Enabled Enables or Disables BIOS support for security device O S will not show Security Device TCG EFI protocol and INT1A interface will not be available TPM State Disabled Enabled Enable Disable Security Device NOTE Your Computer will reboot during restart in order to chan...

Страница 79: ...Hz Supported Enabled All Disabled Enabled Enabled Enabled Enabled Enabled Enabled Select Screen Select Item Enter Select Change Opt F1 General Help F2 Previous Values F3 Optimized Defaults F4 Save Exit ESC Exit Version 2 02 1205 Copyright 2010 American Megatrends Inc Menu Fields Settings Comments Advanced CPU Configuration Hyper threading Disabled Enabled Enabled for Windows XP and Linux OS optimi...

Страница 80: ...le prefetch of next L1 Data line based upon multiple loads in same cache line DCU IP Prefetcher Disabled Enabled Enable prefetch of next L1 line based upon sequential load history Intel Virtualization Technology Disabled Enabled When enabled a VMM can utilize the additional hardware capabilities provided by Vanderpool Technology 4 1 2 2 1 Socket 0 CPU Information Aptio Setup Utility Copyright 2010...

Страница 81: ...BIOS Setup 64 L2 Cache L3 Cache xx kB x 6 xx kB Change Opt F1 General Help F2 Previous Values F3 Optimized Defaults F4 Save Exit ESC Exit Version 2 02 1205 Copyright 2010 American Megatrends Inc ...

Страница 82: ...on power limit 255 Custom Enabled Disabled HW_ALL Disabled Enabled Disalbed No Limit Balanced Performance xx Watts 0 1000 ms 0 1 25 Long Duration 0 Select Screen Select Item Enter Select Change Opt F1 General Help F2 Previous Values F3 Optimized Defaults F4 Save Exit ESC Exit Version 2 02 1205 Copyright 2010 American Megatrends Inc Menu Fields Settings Comments Advanced CPU Configuration CPU Power...

Страница 83: ...Enable Disable CPU C7 ACPI C3 report to OS Package C State Limit C0 C2 C6 C7 No Limit Package C State limit Energy Performance Performance Balanced Performance Balanced Energy Energy Efficient Optimize between performance and power savings Windows 2008 and later OSes overrides this value according to its power plan Note 1 The Turbo mode option is shown when plugged CPU supports this function ...

Страница 84: ...creen Select Item Enter Select Change Opt F1 General Help F2 Previous Values F3 Optimized Defaults F4 Save Exit ESC Exit Version 2 02 1205 Copyright 2010 American Megatrends Inc Menu Fields Settings Comments Advanced CPU Configuration CPU Power Management Configuration QPI Link Frequency Select Auto 6 4 GT s 7 2 GT s 8 0 GT s Allows for selecting the QPI Link Frequency QPI Link1 Disabled Enabled E...

Страница 85: ... Select Screen Select Item Enter Select Change Opt F1 General Help F2 Previous Values F3 Optimized Defaults F4 Save Exit ESC Exit Version 2 02 1205 Copyright 2010 American Megatrends Inc Menu Fields Settings Comments Advanced Runtime Error Logging Runtime Error Logging Support Disabled Enabled Enable Disable Runtime Error Logging Support PCI Error Logging Support Disabled Enabled Enable Disable PC...

Страница 86: ...ot present Not present Not present Not present AHCI Mode Disabled Disabled Disabled Disabled Disabled Disabled Select Screen Select Item Enter Select Change Opt F1 General Help F2 Previous Values F3 Optimized Defaults F4 Save Exit ESC Exit Version 2 02 1205 Copyright 2010 American Megatrends Inc Menu Fields Settings Comments Advanced SATA Configuration SATA Mode Disabled IDE AHCI 1 IDE Mode 2 AHCI...

Страница 87: ...de 4 1 2 4 1 SAS Configuration Aptio Setup Utility Copyright 2010 American Megatrends Inc Advanced SAS Configuration Device0 Device1 Device2 Device3 Device4 Device5 Device6 Device7 Not present Not present Not present Not present Not present Not present Not present Not present Select Screen Select Item Enter Select Change Opt F1 General Help F2 Previous Values F3 Optimized Defaults F4 Save Exit ESC...

Страница 88: ...sion 2 02 1205 Copyright 2010 American Megatrends Inc Menu Fields Settings Comments Advanced USB Configuration Legacy USB Support Enable Disable Auto Enables Legacy USB support AUTO option disables legacy support if no USB devices are connected DISABLE option will keep USB devices available only for EFI applications EHCI Hand off Disabled Enabled This is a workaround for OSes without EHCI hand off...

Страница 89: ...ntroller Auto uses default value for a Root port it is 100 ms for a Hub port the delay is taken from Hub descriptor Device Name 1 Auto Floppy Forced FDD Hard Disk CD ROM Mass storage device emulation type AUTO enumerates devices according to their media format Optical drives are emulated as CDROM drives with no media will be emulated according to a drive type Note 1 The Mass Storage Device is show...

Страница 90: ...itch Enabled Select Screen Select Item Enter Select Change Opt F1 General Help F2 Previous Values F3 Optimized Defaults F4 Save Exit ESC Exit Version 2 02 1205 Copyright 2010 American Megatrends Inc Menu Fields Settings Comments Advanced Runtime Memory Hole Switch Runtime Memory Hole Switch Disabled Enabled Enable AFU to work under Xen Dom0 ...

Страница 91: ...led Select Screen Select Item Enter Select Change Opt F1 General Help F2 Previous Values F3 Optimized Defaults F4 Save Exit ESC Exit Version 2 02 1205 Copyright 2010 American Megatrends Inc Menu Fields Settings Comments Advanced Info Report Configuration Post Report Disabled Enabled Post Report Support Enabled Disabled Info Error Message Disabled Enabled Info Error Message Support Enabled Disabled...

Страница 92: ...elect Item Enter Select Change Opt F1 General Help F2 Previous Values F3 Optimized Defaults F4 Save Exit ESC Exit Version 2 02 1205 Copyright 2010 American Megatrends Inc Menu Fields Settings Comments Advanced Super IO Configuration Serial Port 0 COMA Disabled Enabled Enable or Disable Serial Port COM Device Setting IO 3F8h IRQ 4 Current setting for COM port Serial Port 1 COMB Disabled Enabled Ena...

Страница 93: ...r Select Change Opt F1 General Help F2 Previous Values F3 Optimized Defaults F4 Save Exit ESC Exit Version 2 02 1205 Copyright 2010 American Megatrends Inc Menu Fields Settings Comments Advanced PCI Express Settings Console Redirection Disabled Auto Force L0s Set the ASPM Level Force L0s Force all links to L0s State AUTO BIOS auto configure DISABLE Disables ASPM ...

Страница 94: ...E FW Operation State ME FW Error Code ME Ext FW Status Value BIOS Booting Mode Cores Disabled ME FW SKU Information 2 0 2 1 2 10 0x1f0345 SPS ME FW Active M0 without UMA No Error 0x39002301 Performance Optimized 0 SiEn NM Select Screen Select Item Enter Select Change Opt F1 General Help F2 Previous Values F3 Optimized Defaults F4 Save Exit ESC Exit Version 2 02 1205 Copyright 2010 American Megatre...

Страница 95: ...ot Possible Independent Disabled Auto Auto Auto Enabled Disabled Select Screen Select Item Enter Select Change Opt F1 General Help F2 Previous Values F3 Optimized Defaults F4 Save Exit ESC Exit Version 2 02 1205 Copyright 2010 American Megatrends Inc Menu Fields Settings Comments Advanced Memory Configuration Memory Mode Independent Mirroring Lock Step Sparing Select the mode for memory initializa...

Страница 96: ...Way 4 Way Select different Channel Interleaving setting Rank Interleaving Auto 1 Way 2 Way 3 Way 4 Way Select different rank Interleaving setting Patrol Scrub Disabled Enabled Enable Disable Patrol Scrub Demand Scrub Disabled Enabled Enable Disable Demand Scrubing Feature ...

Страница 97: ...F3 Optimized Defaults F4 Save Exit ESC Exit Version 2 02 1205 Copyright 2010 American Megatrends Inc Menu Fields Settings Comments Advanced Serial Port Redirection Launch PXE OpROM Disabled Enabled Enable or Disable Boot Option for Legacy Network Devices Launch Storage OpROM Disabled Enabled Enable or Disable Boot Option for Legacy Mass Storage Devices with Option ROM Ethernet Controller Disabled ...

Страница 98: ...ect Change Opt F1 General Help F2 Previous Values F3 Optimized Defaults F4 Save Exit ESC Exit Version 2 02 1205 Copyright 2010 American Megatrends Inc Menu Fields Settings Comments Advanced Serial Port Redirection Console Redirection Disabled Enabled Console Redirection Enable or Disable Console Redirection Settings The settings specify how the host computer and the remote computer which the user ...

Страница 99: ... Help F2 Previous Values F3 Optimized Defaults F4 Save Exit ESC Exit Version 2 02 1205 Copyright 2010 American Megatrends Inc Menu Fields Settings Comments Advanced Super IO Configuration Console Redirection Settings Terminal Type VT100 VT100 VT UTF8 ANSI Emulation ANSI Extended ASCII char set VT100 ASCII char set VT100 Extends VT100 to support color function keys etc VT UTF8 Uses UTF8 encoding to...

Страница 100: ...ay require more than 1 stop bit Flow Control None Hardware RTS CTS Flow control can prevent data loss from buffer overflow When sending data if the receiving buffers are full a stop signal can be sent to stop the data flow Once the buffers are empty a start signal can be sent to re start the flow Hardware flow control uses two wires to send start stop signals VT UTF8 Combo Key Supoort Disabled Ena...

Страница 101: ...ve BBS Priorities Network Device BBS Priorities BEV Device BBS Priorities 1 On Disabled xx xx Upon Request Force BIOS Enabled Built in EFI Shell xxxxxxxxxxxxxxx xxxxxxxxxxxxxxx Select Screen Select Item Enter Select Change Opt F1 General Help F2 Previous Values F3 Optimized Defaults F4 Save Exit ESC Exit Version 2 02 1205 Copyright 2010 American Megatrends Inc Menu Fields Settings Comments Boot Se...

Страница 102: ...ROM Message Force BIOS Keep Current Set display mode for Option ROM Interrupt 19 Capture Disabled Enabled Enabled Allows Option ROMs to trap Int 19 Floppy Drive BBS Priorities 1 Hard Drive BBS Priorities 1 CD DVD ROM Drive BBS Priorities 1 Network Device BBS Priorities 1 BEV Device BBS Priorities 1 Set the order of the legacy devices in this group Note 1 these options are shown when plugged corres...

Страница 103: ...ion 2 Boot Option 3 Boot Option 4 xxxxxxxxxxxxx xxxxxxxxxxxxx xxxxxxxxxxxxx xxxxxxxxxxxxx Set the system boot order Select Screen Select Item Enter Select Change Opt F1 General Help F2 Previous Values F3 Optimized Defaults F4 Save Exit ESC Exit Version 2 02 1205 Copyright 2010 American Megatrends Inc ...

Страница 104: ...assword and must be entered to boot or enter Setup In Setup the User will have Administrator rights The password must be in the following range Minimum length 3 Maximum length 20 Administrator Password User Password Set Setup Administrator Password Select Screen Select Item Enter Select Change Opt F1 General Help F2 Previous Values F3 Optimized Defaults F4 Save Exit ESC Exit Version 2 02 1205 Copy...

Страница 105: ...eral Help F2 Previous Values F3 Optimized Defaults F4 Save Exit ESC Exit Version 2 02 1205 Copyright 2010 American Megatrends Inc Menu Fields Settings Comments Save Exit Save Changes and Exit Exit system setup after saving the changes Discard Changes and Exit Exit system setup without saving any changes Save Changes and Reset Reset the system after saving the changes Discard Changes and Reset Rese...

Страница 106: ... Boot Path 4 1 6 Event Logs Aptio Setup Utility Copyright 2010 American Megatrends Inc Main Advanced Boot Security Save Exit Event Logs Server Mgmt View System Event Log View System Event Log Select Screen Select Item Enter Select Change Opt F1 General Help F2 Previous Values F3 Optimized Defaults F4 Save Exit ESC Exit Version 2 02 1205 Copyright 2010 American Megatrends Inc ...

Страница 107: ...hange Opt F1 General Help F2 Previous Values F3 Optimized Defaults F4 Save Exit ESC Exit Version 2 02 1205 Copyright 2010 American Megatrends Inc Menu Fields Settings Comments Server Mgmt FRB 2 Timer Enabled Disabled Enable or Disable FRB2 timer POST timer FRB 2 Timer timeout 3 minutes 4 minutes 5 minutes 6 minutes Enter value Between 3 to 6 min for FRB2 Timer Expiration value FRB 2 Timer Policy D...

Страница 108: ... Select Item Enter Select Change Opt F1 General Help F2 Previous Values F3 Optimized Defaults F4 Save Exit ESC Exit Version 2 02 1205 Copyright 2010 American Megatrends Inc Menu Fields Settings Comments Server Mgmt Erase SEL No Yes On next reset Yes On every reset Choose options for erasing SEL When SEL is Full Do Nothing Erase Immediately Choose options for reactions to a full SEL Log EFI Status ...

Страница 109: ... Manufacturer Board Product Name Board Version Board Serial Number Chassis Manufacturer Chassis Product Name Chassis Serial Number SDR Revision xxxxxx xxxxxx xxxxxx xxxxxx xxxxxx xxxxxx xxxxxx xxxxxx xxxxxx xxxxxx xxxxxx xxxxxx Select Screen Select Item Enter Select Change Opt F1 General Help F2 Previous Values F3 Optimized Defaults F4 Save Exit ESC Exit Version 2 02 1205 Copyright 2010 American M...

Страница 110: ...x xx xx xxx xxx xxx xxx xx xx xx xx xx xx Select Screen Select Item Enter Select Change Opt F1 General Help F2 Previous Values F3 Optimized Defaults F4 Save Exit ESC Exit Version 2 02 1205 Copyright 2010 American Megatrends Inc Menu Fields Settings Comments Server Mgmt BMC network configuration Configuration Address source Unspecified Static Dynamic Obtained by BMC Select to configure LAN channel ...

Страница 111: ...mpt no Himem 3 Run FB BAT or FBB BAT depend on if Boot Block is needed to be update FB BAT Update bios without boot block FBB BAT Update bios with boot block 4 Shutdown and Re start system 4 2 2 2 Recovery Mode A BIOS recovery can be accomplished from one of the following devices an USB Disk On Key CD ROM an ATAPI CD ROM DVD The recovery media must include the BIOS image file B800GXXXX ROM in the ...

Страница 112: ...Appendix China RoHS Regulations ...

Страница 113: ...Appendix TBD I Appendix China RoHS Regulations Appendix Figure I China RoHS Regulations ...

Отзывы: