Retrofit G6+InvencoLink Wayne Vista (US) Installation Guide
4.3
Installation Procedure
This section follows from the Disassembly procedure above, and assumes the pump is still open.
References to
“left-hand” and “right-hand” are as viewed into the pump on the Side you’re working on.
1. Install the pre-assembled EZ0408 PSU Plate Assembly into the pump, in the cavity behind where
the left-hand Display & Printer modules were. For Side A this is the PSU Plate Assembly that has
just had the InvencoLink converter installed:
a. Place the plate up against the standoffs on the left side of the cavity.
b. Secure the plate in place using four MS0154 #8-
32 3/8” screws and a Philips head
screwdriver.
Fig. 3.1
–
Side A
–
PSU Plate installation position
–
Side B
2. Plug the patch cables into the InvencoLink converter sockets:
a. For Side A the converter will be on the plate you have just installed.
i. Plug the EK0129 RED cable into the RS232-1 socket.
ii. Plug the EK0131 YELLOW cable into the LAN-1 socket.
b. For Side B the converter will be on the plate on the other side of the dispenser and you
should run the two cables under any central electronics.
i. Plug the EK0129 RED cable into the RS232-2 socket.
ii. Plug the EK0131 YELLOW cable into the LAN-2 socket.
PSU Plate mounting
screw positions