Invacare® InvaSoft® Hybrid
3 Product Overview
3.1
Product
Description
The
Invacare
InvaSoft
®
Hybrid
mattress
acts
as
a
reactive
pressure
redistributing
support/mattress
for
patients
at
High
Risk
that
can,
by
the
airflow
t hroughout
t he
a ir
cells,
promote
a
pressure
distribution
support
surface.
Due
to
its
unique
construction
combining
foam,
noodle
material,
and
air,
this
mattress
provides
high
user
comfort,
as
well
as
a
solution
for
pressure
care
and
microclimate
management
without
the
need
for
an
external
pump
or
electricity.
The
system
uses
the
user
weight
and
its
movements
to
distribute
the
internal
air
reservoir
amongst
the
cells,
to
always
maintain
optimal
pressure
redistribution.
The
mattress
has
a
sloped
heel
section
for
protection
of
the
vulnerable
heels.
The
high-breathability
water-resistant
cover
provides
a
vapor-permeable,
multi-stretch
surface,
with
enhanced
microclimate
properties,
to
promote
patient
comfort,
contribute
to
skin
integrity
and
maximize
the
effectiveness
of
the
underlying
layers.
The
InvaSoft
®
mattress
is
produced
in
high-quality
materials
for
function
and
durability.
3.2
Intended
Use
This
pressure
redistribution
mattress
is
intended
to
be
used
in
conjunction
with
an
appropriately
sized
bed
frame
and
side
rails.
Check
the
bed’s
user
manual
for
the
appropriate
size
of
the
mattress
to
be
used.
This
product
delivers
effective
pressure
redistribution
to
users,
when
the
support
surface
is
covered
with
a
cotton,
cotton
combination
or
linen
bed
sheet,
and
any
one
of
these
is
the
only
item
deployed
between
the
support
surface
and
the
user.
3.2.1
Indications
Suitable
for
supporting
the
management
of
all
categories
of
pressure
injuries
when
combined
with
an
individual
and
comprehensive
pressure
injury
protocol.
Suitable
for
use
in
home
care,
residential,
nursing
and
acute
care
settings.
3.2.2
Contraindications
Not
suitable
for
users
with
unstable
spinal
cord
fractures
and/or
cervical
traction.
Always
consult
a
physician
prior
to
using
this
device.
3.3
Components
The
following
components
are
included
within
the
scope
of
delivery:
Fig. 3-1
A
Top cover
B
Non-woven top layer
C
Noodle layer
D
Headrest foam
E
Internal spacers
F
Air cell assembly
G
Anti-shear material
H
Heel sloped foam
I
U-core foam
J
Bottom cover
K
User Manual
Stockinette encapsulating all mattress components
within the cover (not shown)
3.4 Symbols on Product
European
Conformity
European
representative
Medical Device
Date of
manufacture
Manufacturer
User weight limit.
See
.
LOT number
Do not put near
flame
Do not pierce or
cut
Hand wash
6
60130102-B