IMPORTANT!
Wrong fluids or methods can harm or damage
the product.
– All cleaning agents and disinfectants used must
be effective, compatible with one another and
must protect the materials they are used to
clean.
– Never use corrosive fluids (alkalines, acid etc.)
or abrasive cleaning agents. We recommend
an ordinary household cleaning agent such as
dishwashing liquid, if not specified otherwise in
the cleaning instructions.
– Never use a solvent (cellulose thinner, acetone
etc.) that changes the structure of the plastic
or dissolves the attached labels.
– Always make sure that the product is completely
dried before taking it into use again.
For cleaning and disinfection in clinical or long-term
care environments, follow your in-house procedures.
Cleaning Intervals
IMPORTANT!
Regular cleaning and disinfection enhances
smooth operation, increases the service life and
prevents contamination.
Clean and disinfect the product
– regularly while it is in use,
– before and after any service procedure,
– when it has been in contact with any body
fluids,
– before using it for a new user.
Cleaning Instructions
IMPORTANT!
– Clean by hand
– Maximum cleaning temperature 60 °C
1.
Clean the product by wiping down all generally accessible
surfaces.
2.
Dry the parts with a cloth.
Disinfection Instructions
Information on recommended disinfectants
and methods can be found on https://vah-
online.de/en/for-users.
In Domestic Care
Method: Follow the application notes for the used
disinfectant and wipe-disinfect all accessible surfaces.
Disinfectant: Ordinary household disinfectant.
Drying: Allow the product to air-dry.
In Clinical and Long Term Care
Follow your in-house disinfection procedures and only use
the disinfectants and methods specified therein.
12 Reconditioning
This product is suitable for reuse. To recondition the product
for a new user, carry out the following actions:
•
Inspection
•
Cleaning and disinfection
For detailed information, see
Make sure that the user manual is handed over with the
product.
If any damage or malfunction is detected, do not reuse the
product.
13 Disposal
Be environmentally responsible and recycle this product
through your recycling facility at its end of life.
Disassemble the product and its components, so the different
materials can be separated and recycled individually.
The disposal and recycling of used products and packaging
must comply with the laws and regulations for waste handling
in each country. Contact your local waste management
company for information.
14 Technical Data (Fig. 9)
Dimensions
A
550 – 560 mm
H
430 mm
B
445 mm
I
180 mm
C
430 – 580 mm
J
145 mm
D
580 mm
K
325 – 475 mm
E
535 – 545 mm
L
250 mm
F
825 – 975 mm
M
215 mm
G
605 – 755 mm
Weights
Shower chair
4.6 kg
Shower and toilet chair with
toilet pan
5.4 kg
Maximum user weight
160 kg
Materials
j
PP with wood fibre
l
TPE
k
Aluminum,
corrosion-free
All product components are corrosion resistant and do not
contain natural rubber latex.
15 Environmental Parameters
Operating Conditions
Ambient temperature
10 - 40 °C
Relative humidity
15% - 93%, non-condensing
Storage and Shipping Conditions
Ambient temperature
0 - 40 °C
Relative humidity
30% - 75%, non-condensing
I
de
I
1 Einleitung
Diese Gebrauchsanweisung enthält wichtige Informationen zur
Handhabung des Produkts. Lesen Sie die Gebrauchsanweisung
sorgfältig durch und befolgen Sie die Sicherheitsanweisungen,
damit eine sichere Verwendung des Produkts gewährleistet
ist.
Invacare behält sich das Recht vor, Produktspezifikationen
ohne vorherige Ankündigung abzuändern.
Vergewissern Sie sich vor dem Lesen dieses Dokuments,
dass Sie die aktuelle Fassung haben. Die jeweils aktuelle
1644798-C
5
Содержание Aquatec PICO 3in1 GREEN
Страница 2: ...Aquatec PICO GREEN Fig 7 Fig 8 Fig 9 Fig 10 2 1644798 C...
Страница 31: ...Notes...