background image

1

Installation, Assembly and Operating Instructions

NOTE: Check ALL parts for shipping damage. In case
of shipping damage, DO NOT use. Contact Carrier/
Dealer for further instruction.

SAFETY SUMMARY

The following recommendations are made for safe in-
stallation and adjustment of the Patient Operated
Wheel Locks:

GENERAL WARNINGS

DO NOT install or use this kit without first read-
ing and understanding this instruction sheet. If
you are unable to understand the Warnings,
Cautions or Instructions, contact a healthcare
professional, dealer or technical personnel be-
fore attempting to install this kit - otherwise, in-
jury or damage may occur.

INSTALLATION WARNINGS

After making adjustments and BEFORE use,
make sure all attaching hardware is securely
tightened.

INSTALLATION CAUTIONS

When securing the strap and stud assembly to
the pivot arm assembly, DO NOT overtighten
the attaching hardware.

REPLACING THE PATIENT
OPERATED WHEEL LOCKS
(FIGURE 1)

NOTE: Refer to INSTALLATION WARNINGS and
CAUTIONS
 in the SAFETY SUMMARY in this instruc-
tion sheet.

NOTE: If converting from attendant operated wheel
lock, refer to CONVERTING FROM ATTENDANT
OPERATED WHEEL LOCKS 
 in this instruction sheet.

1. Remove the axle mounting screw and locknut that

secure the rear portion of the existing patient op-
erated wheel lock, pivot arm spacer and rear wheel
to the wheelchair frame.

2. Remove the existing 2-inch mounting screw, bush-

ing, thin washer, and locknut that secure the ex-
isting strap and stud assembly to the wheelchair
frame. Refer to DETAIL “A” in FIGURE 1.

PATIENT OPERATED WHEEL LOCKS
FOR 2000/4000 RECLINER WHEELCHAIRS
KIT NUMBERS 1034177

3. Remove the existing tube clamp from the wheel-

chair frame.

4. Install the plug button into end of the NEW pivot

arm assembly.

5. Insert the NEW strap and stud assembly through

the pivot arm assembly and secure with locknut.

6. Install the NEW tube clamp over the frame and

measure 4-3/16-inches from the back tube of the
frame assembly to the center of the tube clamp.

7. Insert the NEW 2-inch mounting screw through

the NEW tube clamp, bushing, strap/stud assem-
bly and thin washer.

8. Install locknut onto 2-inch mounting screw. Tighten

until snug fit is obtained.

9. Insert the pivot arm spacer into the end of the NEW

pivot arm assembly.

10. Insert the existing axle mounting screw through

the rear wheel, pivot arm spacer, NEW pivot arm
assembly and axle lug.

11. Install locknut onto axle mounting screw. Securely

tighten.

12. Attach the wheel lock assembly to the NEW pivot

arm assembly by using the 3/4-inch mounting
screw and heavy washer.

13. Repeat STEPS 1-12 for opposite wheel lock.

14. Adjust the wheel locks. Refer to ADJUSTING THE

PATIENT OPERATED WHEEL LOCKS in this in-
struction sheet.

Содержание 1034177

Страница 1: ...the existing patient op erated wheel lock pivot arm spacer and rear wheel to the wheelchair frame 2 Remove the existing 2 inch mounting screw bush ing thin washer and locknut that secure the ex isting strap and stud assembly to the wheelchair frame Refer to DETAIL A in FIGURE 1 PATIENT OPERATED WHEEL LOCKS FOR 2000 4000 RECLINER WHEELCHAIRS KIT NUMBERS 1034177 3 Remove the existing tube clamp from...

Страница 2: ...nch Mounting Screw STEPS 2 7 Pivot Arm Assembly STEPS 1 4 5 9 10 12 Wheelchair Frame 3 4 inch Mounting Screw STEP 12 Heavy Washer STEP 12 Axle Mounting Screw STEPS 1 10 11 DETAIL A Back Tube STEP 6 FIGURE1 REPLACINGTHEPATIENTOPERATEDWHEELLOCKS Tube Clamp STEPS 3 6 7 Bushing STEPS 2 5 7 Strap Stud Assembly STEPS 2 7 Thin Washer STEPS 2 7 Locknut STEPS 2 8 ...

Страница 3: ...the wheelchair holds its position 5 Repeat the above procedures until the wheel lock holds the wheelchair 6 Repeat STEPS 1 5 for the opposite wheel lock Wheel Lock Handle Bolt and Locknut Wheel Lock Shoe 5 32 and 5 16 inches Rear Wheel FIGURE2 ADJUSTINGTHEPATIENT OPERATEDWHEELLOCKS Wheel Lock USING THE PATIENT OPERATED THE WHEEL LOCKS FIGURE 3 WARNING DO NOT attempt to stop a moving wheelchair wit...

Страница 4: ... and rear wheel to the wheel chair frame 8 Installtheplugbuttonintoendofpivotarmassembly 9 Insert the strap and stud assembly through the pivot arm assembly and secure with locknut 10 Install the tube clamp over the frame and mea sure 4 3 16 inches from the back tube of the frame assembly to the center of the tube clamp 11 Insert the 2 inch mounting screw through the tube clamp bushing strap studa...

Страница 5: ...ew STEPS 13 14 Tube Clamp Bushing Strap Stud Assembly ThinWasher Locknut STEPS 9 11 Back Tube STEP 10 Mounting Screw STEPS 2 6 Locknut STEPS 2 6 Locking Rod STEPS 2 6 Anti Rattle STEPS 3 5 6 Recliner Tube STEPS 1 5 BackTube Mounting Bracket STEPS 2 6 Bolt and Locknut STEP 1 Attendant Operated Wheel Lock STEPS 1 4 5 Locknut STEPS 2 6 Recliner Tube STEPS 1 5 6 FIGURE4 CONVERTINGFROMATTENDANTOPERATED...

Страница 6: ...embly 2 4 Locknut 2 5 5 16 24x2 inch Mntg Screw 2 6 Tube Clamp 2 7 Bushing 2 8 Thin Washer 2 9 Locknut 2 10 Pivot Arm Spacer 2 11 Wheel Lock Assembly 2 12 Axle Locknut 2 13 3 4 inch Mntg Screw 2 14 Washer Heavy 2 15 Axle Mounting Screw 2 PARTS LIST 1 2 5 12 6 7 3 8 9 4 10 15 11 13 14 ...

Страница 7: ...7 NOTES ...

Страница 8: ...INVACARECORPORATION lONEINVACAREWAY lP O Box4028 lElyria Ohio44036 2125 l Phone 1 800 333 6900 Form No 94 170 Part No 1052754 Rev 1 3 98 Printed in U S A ...

Отзывы: