5.11
Check and top up the hydraulic fluid level
Before you begin
Condition: the temperature of the hydraulic fluid must be approximately 20° C.
Procedure
1. Check the liquid level in the sight
glass (A).
The fluid level must be as far as the
bottom red mark (B).
2. If the fluid level is too low:
a) Remove the bolt and the nut (C).
b) Remove the filler cap (D).
c) Fill up the tank.
For the correct type of hydraulic
d) Refit the filler cap and secure the
filler cap with the bolt and nut.
3. If the fluid level is too high, contact a
qualified service technician.
5.12
Replace the air filter
Spares
• For the correct replacement parts, contact the manufacturer.
Safety
Note: This procedure may only be carried out by a qualified service
technician.
4
2
3
1
0
D
A
B
C
A
Maintenance
40
11 - 002 - 30.08.2018