Commissioning and operation
INTORQ | BA 14.0199 | 08/2016
34
6
Commissioning and operation
6.1
Important notes
❚
The brake is designed for operation under the environmental conditions that apply to IP66 protection.
Because of the numerous possibilities of using the brake, it is however necessary to check the function-
ality of all mechanical components under the corresponding operating conditions.
DANGER
There is a risk of injury by electrical shock!
❚
Electrical connection must only be carried out by skilled personnel!
❚
Only carry out connection work when no voltage is applied (no live parts)! There is a risk of
unintended start-ups or electric shock.
DANGER
Danger: rotating parts!
The brake must be free of residual torque.
The drive must not be running when checking the brake.
CAUTION
Danger: hot surfaces. Do not touch!
NOTICE
Functionality for different operating conditions
❚
The brakes are dimensioned in such a way that the given rated torques are reached safely
after a short run-in process.
❚
However, as the organic friction linings used do not all have identical properties and because
environmental conditions can vary, deviations from the specified braking torques are possi-
ble. These must be taken into account in the form of appropriate dimensioning tolerances.
Increased breakaway torque is common, in particular after long downtimes in humid environ-
ments where temperatures vary.
NOTICE
Operation without dynamic loads (functioning as a pure holding brake)
❚
If the brake is used as a pure holding brake without dynamic load, the friction lining must be
reactivated regularly.