Product description
INTORQ | BA 14.0214 | 10/2019
14
3.6
Optional configuration
3.6.1
Hand-release (optional)
To temporarily release the brake when there is no electricity available, a hand-release function is available
as an option. The hand-release function can be retrofitted.
3.6.2
Optional micro-switch
The micro-switch is used for the release monitoring or for wear monitoring. The user is responsible for ar-
ranging the electrical connection for this optional micro-switch.
¾
Usage for the (air) release monitoring: The motor will start only after the brake has been released. This
enables the micro-switch to monitor for errors (e.g. when the motor does not start because of a defect-
ive rectifier, if there are broken connection cables, defective coils, or an excessive air gap).
¾
Usage for monitoring wear: The brake and motor are not supplied with power when the air gap is too
large.
3.6.3
Optional encapsulated design
This design not only prevents the penetration of spray water and dust, but also the spreading of abrasion
particles outside the brake. This is achieved by the following enclosures:
¾
A cover ring over the armature plate and rotor.