The  finger  pulse  oximeter  produced  by  our  company  is  a 

kind of noninvasive and continuous medical instrument for 

detecting the arterial oxygen saturation and pulse rate of 

human body. It is portable and can accurately and rapidly 

measure the blood oxygen, so that you know whether you 

are lack of oxygen at present.

USER MANUAL 

Содержание Oxicare

Страница 1: ...f noninvasive and continuous medical instrument for detecting the arterial oxygen saturation and pulse rate of human body It is portable and can accurately and rapidly measure the blood oxygen so that you know whether you are lack of oxygen at present USER MANUAL ...

Страница 2: ...ime The finger clip type pulse oximeter hereinafter referred to as the oximeter has the advantages of small volume low power consumption simple operation and convenient carrying When measuring as long as the finger is extended into the finger clamp photoelectric sensor the display screen will directly display the measured blood oxygen saturation value The measurement principle of the oximeter is b...

Страница 3: ...t can not be used together with MRI or CT equipment 2 Explosion hazard do not use this instrument in the environment of flammable anesthetic gas 3 The oximeter only plays an auxiliary role in the diagnosis of the patient Please ask the doctor to make a diagnosis based on the clinical manifestations and symptoms 4 Always check the sensor test point of the oximeter to confirm that the patient s skin...

Страница 4: ... saturation will be affected by the strong light of the surrounding environment e g wipes or direct sunlight add a protective enclosure to the sensor if necessary 13 The patient s unexpected movements may cause incorrect readings 14 The interference of medical high frequency signal or defibrillator may cause wrong reading 15 Rhythmic pulsation of the vein can cause incorrect readings 16 The measur...

Страница 5: ...ectly fasten the battery cover 2 Insert the finger into the rubber hole the finger should be fully extended with the nail facing up and then release the clamp 3 Press the button in the middle of the front panel to start the oximeter for blood oxygen detection 4 In the use process it is better not to shake your fingers and the human body should not be in motion 5 If you want to change the display d...

Страница 6: ...de effects such as allergy to human skin Key function description in the standby mode start the key instrument to enter the working mode and press the key in the working mode to change the display mode 2 Pulse oxygen saturation display range 35 100 3 Blood oxygen saturation measurement accuracy within the range of 70 99 2 70 no definition of 5 1 2 3 4 Report errors Brief introduction of the whole ...

Страница 7: ... the necessary test equipment bio tek index pulse oximeter can measure the available pulse wave signal whose amplitude is 6 of the amplitude of analog pulse wave signal 11 Anti environment light interference ability apply interference signal test with intex pulse oximeter tester the instrument can work normally 1 According to the management category of medical devices it is divided into Class II e...

Страница 8: ...The user must ensure that the product is used in the following environment 1 1pcs lanyard 2 1pcs User manual 7 Spare parts Product statement electromagnetic radiation for other equipment and systems Radiation test RF interference CISPR 11 RF interference CISPR 11 Basis Group 1 Class B Electromagnetic environment Guidance The RF signal of the oximeter is only generated by the internal function so i...

Страница 9: ...king or human body moving 1 The battery may be low or dead 2 The battery may not be installed correctly 3 The machine may be damaged 1 The product is set to stand by after 8 seconds when there is no detection signal 2 Low battery Blood oxygen or heart rate is unstable Unable to power on The display light goes out suddenly 1 Please put your finger in correctly and try again 2 Please try to keep you...

Страница 10: ...efer to the manual before use Perfusion Index Blood oxygen saturation Pulse rate beats per minute Low voltage indication Serial number Enterprise Name Zhengzhou AiQURA Intelligent Technology Co Ltd Address 4th Floor Building 26 Smart phone industrial park Intersection of xingang Avenue and Renmin road Zhengzhou airport economic comprehensive experimental zone ...