background image

189

PO

(189PO)  MODEL CS7111  SALTWATER SYSTEM & FILTER PUMP  ENGLISH  7.5” X 10.3”  PANTONE 295U  06/28/2013

English

OWNER’S 

MANUAL

Krystal Clear Saltwater 

System

®

 & Filter Pump

Model CS7111

IMPORTANT 

SAFETY RULES

Read, understand, and follow 

all instructions carefully before 

installing and using this product.

IMPORTANT!

DO NOT RETURN PRODUCT TO STORE

To purchase parts and accessories or to obtain non-technical assistance, Visit

 

www.intexcorp.com

For technical assistance and missing parts call us toll-free (for U.S. and Canadian Residents):

1-800-234-6839

Monday through Friday, 8:30am to 5:00pm Pacific Time

Don’t forget to try these other fine Intex products: Pools, Pool 

Accessories, Inflatable Pools and In-Home Toys, Airbeds and 

Boats available at fine retailers or visit our website listed below.

Due to a policy of continuous product improvement, Intex 

reserves the right to change specifications and appearance, 

which may result in updates to the instruction manual without 

notice.

189-*PO-R0-1406

For illustrative purposes only. 

Содержание CS7111

Страница 1: ...nce Visit www intexcorp com For technical assistance and missing parts call us toll free for U S and Canadian Residents 1 800 234 6839 Monday through Friday 8 30am to 5 00pm Pacific Time Don t forget to try these other fine Intex products Pools Pool Accessories Inflatable Pools and In Home Toys Airbeds and Boats available at fine retailers or visit our website listed below Due to a policy of conti...

Страница 2: ...ns 7 10 Salt Pool Water Volumes 11 Intex Pools Salt Table 12 Intex Pools Cyanuric Acid Table 13 Intex Pools Operating Time Table 14 Non Intex Pools Salt Table 15 Non Intex Pools Cyanuric Acid Table 15 Non Intex Pools Operating Time Table 15 Operating Instructions 16 18 LED Code Chart 19 Maintenance 20 22 Long Term Storage 23 Pool Maintenance and Chemical Definitions 24 Troubleshooting Guide 25 27 ...

Страница 3: ...roduct The unit is provided with a ground fault circuit interrupter GFCI To test the GFCI push the test button The GFCI should interrupt power Push the reset button power should be restored If the GFCI fails to operate in this manner The GFCI is defective If the GFCI interrupts power to the pump without the test button being pushed a ground current is flowing indicating the possibility of an elect...

Страница 4: ...RTS REFERENCE Before assembling your product please take a few minutes to check the contents and become familiar with all the parts Optional NOTE Drawings for illustration purpose only Actual product may vary Not to scale 1 2 3 4 6 5 8 8 7 1 2 10 9 39 13 14 15 12 16 17 30 40 18 11 31 32 37 38 19 20 21 22 23 24 25 35 19 20 21 26 27 29 35 19 21 26 35 19 20 22 23 24 35 21 28 27 20 ...

Страница 5: ...AR AND 2 HOSE CLAMPS 1 11583 10 SCREW 2 11519 11 FLOW SENSOR 1 11460 12 ELECTROLYTIC CELL NUT 1 11582 13 ELECTROLYTIC CELL O RING C INCLUDED 1 11578 14 COPPER ELECTRODE 1 11579 15 L SHAPE O RING 1 11228 16 O RING C 1 10717 17 ANGLE JOINT O RING D INCLUDED 1 11584 18 O RING A 1 11587 19 PLUNGER VALVE HOSE O RING STEP WASHER INCLUDED 2 10747E 20 HOSE O RING 2 10262 21 STEP WASHER 2 10745 22 STRAINER...

Страница 6: ...ater flows through the saltwater system s electrolytic cell to produce HCLO The HCLO dissolves in the water and instantly starts destroying bacteria and algae It also oxidizes all other organic materials Low voltage direct current is applied to the copper electrode and copper ions are generated and dissolved instantly in the water Copper is an effective algaecide which will prevent algae from grow...

Страница 7: ...n from the threaded strainer connector 24 Be careful not to lose the step rubber washer 21 3 Grasp the plunger valve assembly Make sure the step washer 21 is in place Connect adaptor B 26 to plunger valve union 4 Repeat steps 1 through 3 for nozzle and plunger valve mechanism 5 Remove wall plug and then insert the strainer 27 29 into the lower position of protruding hose connection and the nozzle ...

Страница 8: ...nd plunger valve at the lower position of pool outlet marked From the inside of the pool liner insert the connector 24 into one of the pre cut holes with the washer remaining on the connector to be placed against the inside of the liner wall 4 Before assembly lubricate the threads with a petroleum jelly Then with the flat side of the strainer nut 22 facing the outside wall of the liner in a clockw...

Страница 9: ... 5 Before assembly lubricate the threads with a petroleum jelly Then with the flat side of the strainer nut 22 facing the outside wall of the liner in a clockwise motion screw the strainer nut 22 back onto the threaded connector 24 see drawing 6 6 Finger tighten the adjustable pool inlet nozzle 25 and the strainer nut 22 onto the threaded connector 24 7 Grasp the plunger valve assembly Make sure t...

Страница 10: ...ight system In a counter clockwise motion turn both air release valves 1 7 1 2 turns to open DO NOT remove air release valves as water will expel with force if the motor is turned on and injury may occur 6 Grasp and remove the filter housing cover 4 Check to see if a cartridge is inside the housing If yes replace the cover finger tighten the housing collar 3 back onto the filter housing 7 Gently f...

Страница 11: ...is not lost due to evaporation Adding Salt 1 Switch on the unit then press and hold both and button for 5 seconds the LED flashes FP The unit is now in a Filter pump working mode and switch the filter pump on to start the water circulation 2 Keep the saltwater system turned off 3 Determine the amount of salt to be added see Salt Table 4 Evenly spread the proper amount of salt around the inside per...

Страница 12: ...95 45 25 10 488cmx122cm 16 x48 4273 16173 110 50 30 15 488cmx132cm 16 x52 4614 17464 115 50 30 15 549cmx107cm 18 x42 4786 18115 120 55 30 15 549cmx122cm 18 x48 5455 20647 135 60 35 15 CIRCULAR METAL FRAME POOL 457cmx91cm 15 x36 3282 12422 80 35 20 10 457cmx107cm 15 x42 3861 14614 100 45 25 10 457cmx122cm 15 x48 4440 16805 110 50 30 15 488cmx122cm 16 x48 5061 19156 125 55 35 15 549cmx122cm 18 x48 6...

Страница 13: ...sy Set Oval Pool Cyanuric Acid Needed for Startup 0 03g L 30ppm Gals Liters Lbs Kgs INTEX ABOVE GROUND POOLS AGP s EASY SET POOL 457cmx84cm 15 x33 2587 9792 0 6 0 3 457cmx91cm 15 x36 2822 10681 0 7 0 3 457cmx107cm 15 x42 3284 12430 0 8 0 4 457cmx122cm 15 x48 3736 14141 0 9 0 4 488cmx107cm 16 x42 3754 14209 0 9 0 4 488cmx122cm 16 x48 4273 16173 1 1 0 5 488cmx132cm 16 x52 4614 17464 1 2 0 5 549cmx10...

Страница 14: ...7cm 16 x42 3754 14209 4 4 5 488cmx122cm 16 x48 4273 16173 4 5 6 488cmx132cm 16 x52 4614 17464 5 5 6 549cmx107cm 18 x42 4786 18115 5 5 6 549cmx122cm 18 x48 5455 20647 6 6 7 CIRCULAR METAL FRAME POOL 457cmx91cm 15 x36 3282 12422 3 4 5 457cmx107cm 15 x42 3861 14614 4 4 5 457cmx122cm 15 x48 4440 16805 5 5 6 488cmx122cm 16 x48 5061 19156 5 6 7 549cmx122cm 18 x48 6423 24311 7 7 8 ULTRA FRAME POOL 488cmx...

Страница 15: ...city Liters x 0 003 Water Capacity Gals x 0 0067 Water Capacity Liters x 0 0008 CYANURIC ACID TABLE FOR COMMON NON INTEX POOLS Water Capacity Salt Needed for Startup Salt Needed when Low Salt Detected CODE 91 Gals Liters Lbs Kgs Lbs Kgs 2000 7500 50 20 10 5 4000 15000 100 45 25 10 6000 22500 150 65 40 20 7000 26500 175 80 55 20 Water Capacity Operating Time hours at different ambient air temperatu...

Страница 16: ...ill automatically activate to minimize the suction at the pool outlet if the outlet is blocked This is an additional safety feature to prevent suction entrapment The vacuum release valve will reset once the blockage is removed and the pump is switched off To restart the system the air must be removed from the filter pump per previous step 5 Turn on the switch The filter pump is now filtering the w...

Страница 17: ...altwater System at the same time each day for the number of hours you have set NOTE The Saltwater System will not operate if the filter pump is not operating 3 Lock keypad controls With the desired hour value showing press button until you hear a beep The green WORKING indicator on the control panel will light up within a few seconds to indicate that the saltwater system has started sanitizer prod...

Страница 18: ...e chlorine is between 0 5 3 ppm and copper ion concentration is between 0 1 0 2 ppm When the copper level is below 0 1 ppm repeat step 6 NOTE A High copper ion concentration may cause blonde hair to exhibit a green hair To prevent this wear a swimming cap during swimming and wash hair with special shampoo after using the pool See Troubleshooting Guide 8 Stand by power saving mode When the cycle en...

Страница 19: ...accept any interference including interference that may cause undesired operation of the device Changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment This equipment has been tested and found to comply with the limits for Class B digital device pursuant to part 15 of the FCC Rules These limits are designed to...

Страница 20: ...nsor then use a garden hose to wash it off 3 If flushing with water does not remove the deposits use a plastic brush to clean the surface and the hinge if necessary Do not use a metal brush 4 After the flow sensor has been inspected and cleaned align the locator notch on the flow sensor to the connection ridge in the conduit Now turn the collar in a clockwise motion tightening the sensor back into...

Страница 21: ...rom the Saltwater System and assemble the cell cover 30 at the side of the cell 4 In a counter clockwise motion unscrew the collar of the copper electrode 14 and remove it from the electrolytic cell Lift up the copper electrode 5 Pour kitchen grade vinegar into the cell to immerse the titanium plates Then put the copper electrode back in the cell soak them for about one hour until no colored areas...

Страница 22: ...cartridge 7 Examine the inside of the filter housing 8 If dirt or sediment is located on the bottom of the housing then A In a counter clockwise motion gently unscrew and remove the sediment valve 1 located at the bottom of the housing Place it in a safe place B With a bucket of water or a garden hose pour water into the housing flushing out the sediment C Screw back the sediment valve 1 in a gent...

Страница 23: ... immediately 2 Hold the strip level for 15 seconds Do not shake excess water from the strip 3 Now compare the strip pad to the color chart on the packaging label If necessary adjust the chemical level in the pool water It is very important to use the proper technique when testing the water s chemical level Read and follow the written strip instructions carefully 1 Disconnect the power cord from th...

Страница 24: ...tion is Result if too low Corroded metals eye skin irritation destruction of total alkalinity Result if too high Scale formation cloudy water shorter filter runs eye skin irritation poor Chlorine efficiency Total Alkalinity Indicates the degree of the water s resistance to change in pH It determines the speed and ease of pH change so always adjust total alka linity before adjusting the pH level Re...

Страница 25: ...f circuit breaker and call an electrician to correct the problem Let motor cool down Adjust the sanitizer and pH level Consult your local swimming pool supply stores Clean or replace cartridge Check the cartridge for holes Replace if damaged Operate the filter for longer periods Clean the strainer screen at the inlet Clear any obstructions in the intake hose by discharging it inside pool wall Tigh...

Страница 26: ...the water using the test strips If the pool is clean and clear add stabilizer to the water and then test the water with the device running Increase operating time per day See Operating Instructions Use PH decrease chemical to adjust contact your local pool chemical store Increase the operating time per day See Operating Instructions Remove the cell for inspection clean it if necessary See Maintena...

Страница 27: ...nlet and the outlet hose Reverse the hoses if necessary See Set Up Instructions Clean the flow sensor paying special attention to the hinge See Maintenance Plug the flow sensor firmly into the flow sensor receptacle Reset both timers on the filter pump and saltwater system See Boost Cycle Contact Intex Service Center Remove the electrolytic cell for inspection Clean it if necessary See Maintenance...

Страница 28: ...und the pool Learn to swim Take the time to learn CPR and first aid Instruct anyone who is supervising pool users about potential pool hazards and about the use of protective devices such as locked doors barriers etc Instruct all pool users including children what to do in case of an emergency Always use common sense and good judgement when enjoying any water activity Supervise supervise supervise...

Страница 29: ...tem will be repaired or replaced at no charge Any and all disputes regarding the provisions of this Limited Warranty shall be brought before an informal dispute settlement board and unless and until the provisions of these paragraphs are carried forth no civil action may be instituted The methods and procedures of this settlement board shall be subject to the rules and regulations set forth by the...