3. General safety instructions
The electrical components must be installed only by a qualified electrician
according to local regulations. In case of failure of an electronic component,
the product must be repaired by a qualified electrician before being
operated again. There is a risk of electric shock and fire!
The outlet circuit used for the device shall be secured and protected with a
circuit breaker (e.g. 16 A in several countries). If unavailable, an FI switch with
maximum operating current of 30 mA shall be connected.
When working inside of the tank or on electrical components always unplug
the power cord and disconnect the circuit breaker first.
Local rules and electrical standards must be considered!
These installation and operating guidelines must be read carefully before
installing the product. The instructions mentioned must be followed strictly.
Modifications to the product are not permitted, otherwise the warranty
becomes void.
Local rules and safety standards must be considered!
The following points must be strictly observed during the installation and operation:
Check the product before installation for any visible defects. If defects are present, then the
product must not be installed. A damaged product can be dangerous.
A floor drain must be provided near the installation site, which can collect inadvertent water
discharge (such as with pump defect, pipe breakage etc.) and prevent water damage inside the
building. The brickwork behind the tank installation position should be protected from water
(such as with water-resistant paint).
Make sure that the existing emergency overflows are connected and adequately sized.
All products must be regularly inspected to maintain proper condition. The minimum inspection
interval is mentioned in the maintenance chapter.
Electrical devices may be hazardous for children. Do not let children near the product.
Do not install the water-handling products in locations where the temperature may drop below 0°C.
Do not install any electrical products in areas of water risk.
The operator is responsible for adherence of the safety and maintenance guidelines.
Access ports of the tank system shall be protected against unauthorized intrusions (e.g. lockable
plant room, a padlock, locking the cover with specialized tools or cover with net weight > 30 kg).
The national and local regulations with regards to the installation and operation of a greywater
treatment system must be complied by the installer as well as the operator.
Содержание AQUALOOP GW 10800
Страница 10: ...9 Tab Official listing https www intewa de en applications rain greywater harvesting greywaterrecycling...
Страница 12: ...11 Fig AQUALOOP System 1200 L day 317 GPD Fig AQUALOOP System 1800 L day 476 GPD...
Страница 13: ...12 Fig AQUALOOP System 3600 L day 952GPD Fig AQUALOOP System 5400 L day 1428 GPD...
Страница 37: ...36 Fig Electrical connection plan upper pump lower pump...
Страница 39: ...38 Fig Control cabinet of multiple membrane station controller...
Страница 42: ...41 7 1 3 Expansion membrane station controller Fig Control cabinet of expansion controller...
Страница 89: ...88 Designed and provided by INTEWA GmbH or to be separately approved alternative...
Страница 90: ...89 INTEWA GmbH Version 1 1 a Subject to technical changes...