Cleaning the Earmould (if applicable)

First, remove the earmould from the receiver unit. Use luke-

warm water to clean the earwax off the earmould (Never clean 

the receiver unit with water!) If earwax is stuck in the sound 

canal of the earmould, the cleaning loop or a syringe with luke-

warm water can easily be used to “push” the earwax out.

Be sure to thoroughly dry the earmould before reconnecting it 

to the hearing aid. Blow gently through it to remove moisture 

trapped inside.

The receiver unit should be changed by your hearing healthcare professional if the 

tube becomes stiff or brittle.

Note

: Your hearing instruments have been equipped with filters. For more information, 

 

please refer to the “Earwax Management” section.

Changing the Dome

We recommend that you have your hearing healthcare professional change the dome 

for you if it becomes stiff or brittle. If he or she instructs you to change the dome 

yourself, make sure that it is securely fastened to the receiver before inserting it into 

your ear. A failure to change the dome in accordance with the instructions that follow 

could result in injury.

How to Mount a Dome (Open Dome or Tulip-Dome)

A dome is mounted by pushing it over the end of the receiver 

tube. Be sure to push the dome down onto the receiver as 

much as possible to ensure that it stays on the receiver.

Note

: If you experience difficulties with mounting of 

the Dome, consult your hearing healthcare professional.

Содержание A160-D

Страница 1: ...1 User Guide Digital Receiver in the Ear instrument RIE A160 D A160 D Open A160 D HPG...

Страница 2: ...u get more comfortable with the system increase the wearing time and wear your hearing system in multiple types of listening environments It may take as long as several months for your brain to get us...

Страница 3: ...me Control Battery Compartment and On Off switch AVIO 1 Receiver In the Ear RIE Receiver Tube Tube Microphone 2 Sound Inlet Receiver Sound Outlet Dome Earmould Manufacturer Serial Number Model INTERTO...

Страница 4: ...l not deliver sound to the ear If your hearing instrument has a Memory Selector you can put the instrument into stand by mode by holding down the Memory Selector for five seconds You will hear a serie...

Страница 5: ...ry 1 is activated two tones will sound when Memory 2 is activated etc Memories are always activated in sequence for example with three memories 1 to 2 2 to 3 3 to 4 4 to 1 Consult your hearing healthc...

Страница 6: ...f your head Note When the receiver dome is placed correctly you should not see the tube sticking out when looking directly into a mirror If you have not already turned on your hearing instrument switc...

Страница 7: ...p and down and press gently to ensure it is positioned correctly in the ear You will feel when the ear mould is positioned correctly Switch on your hearing aid Tip Insertion of the earmould can be eas...

Страница 8: ...activate the telecoil you will need to use the memory selector to activate the appro priate memory To use the telephone while the telecoil is activated position the telephone near but not directly on...

Страница 9: ...ent completely by pressing the tab on the base of the instrument with your fingertip until the battery door snaps partly open then put your fingernail under the nail grip and pull gently to open it co...

Страница 10: ...and will continue beeping until the instrument automatically switches off Tip It is helpful to keep spare batteries with you in case you need them Battery Safety Dispose of used batteries properly Ke...

Страница 11: ...properly Use the soft brush provided with your hearing instruments to remove dust or other debris from the sound inlets Cleaning the Receiver Dome and Tube If you have a receiver dome and tube they s...

Страница 12: ...uments have been equipped with filters For more information please refer to the Earwax Management section Changing the Dome We recommend that you have your hearing healthcare professional change the d...

Страница 13: ...rwax If appro priate your hearing health professional will have selected and installed an ear wax management system on your instruments You will need to discuss with your hearing healthcare profession...

Страница 14: ...ituations to avoid Do not wear your hearing system when using a hair dryer Do not leave your hearing system in your car or in direct sunlight Do not attempt to dry your hearing system in any device ot...

Страница 15: ...cosmetics e g perfume aftershave hair spray suntan lotion Instruments should be used only as prescribed by your hearing care professional Incorrect use may result in sudden and permanent hearing loss...

Страница 16: ...battery in the instrument Is the battery still good Is you ear full of wax SYMPTOM CAUSE POSSIBLE REMEDY Solving small problems Your Interton instrument is a reliable one In case of minor problems or...

Страница 17: ...attery dirty Did your instrument get moist Did you leave your hearing instrument switched on at night Is the battery old SYMPTOM CAUSE POSSIBLE REMEDY Replace it with a new one Clean it or use a new o...

Страница 18: ...ephones etc will not damage the instrument They could however momentarily affect the sound quality or create strange sounds from the instruments Warning Do not wear the instrument in mines or other ex...

Страница 19: ...of the hearing instrument since this would invalidate the warranty If your Interton hearing instrument requires service please con tact your hearing care professional for assistance Technical Specifi...

Страница 20: ...38 39 Notes Notes...

Страница 21: ...terton A S Lautrupbjerg 7 DK 2750 Ballerup Denmark Tel 45 45 75 1111 Fax 45 45 75 1119 www interton com Any issues relating to the EU Medical Device Directive 93 42 EEC should be directed to Interton...

Отзывы: