Weld-i
TM
HD 625
Instruction & Admin Manual
Page 31 of 47
InterTest, Inc. • 303 Route 94 • Columbia, NJ 07832
+1 (908) 496-8008 •
Released 8-20-21
Command
Inquiry Hex
Reply HEX
Definition
Read P Version 43 09 E0 00 00 00 00 FF 43 09 EE 00 00 qr st FF
Returns PIC Version qr st in
hex. LCD shows in decimal.
Read E Version 43 09 E1 00 00 00 00 FF 43 09 EE 00 00 qr st FF
Returns EM Version qr st in
hex. LCD shows in decimal.
Weld-i
TM
HD 625 RS232 Commands
Command
Command HEX
Definition
off
44 01 01 00 00 00 00 FF
Turns both motors off
Filter/Iris Motor Control 44 01 01 01 00 00 0q ff
q: 0 = turn filter/iris motor off
q: 1 = filter up or Iris close
q: 2 = filter down or iris open
Focus Motor Control
44 01 01 01 00 01 0q ff
q: 0 = turn focus motor off
q: 1 = focus far
q: 2 = focus near
Arc_Off
44 01 02 00 00 00 00 ff
Turns Arc function off
Arc_On
44 01 02 01 00 00 00 ff
Turn Arc function on
Arc_Set
44 01 02 01 00 00 01 ff
Sets Arc shutter value to current shutter setting
Arc_Reset
44 01 02 04 00 00 00 ff
Resets Arc shutter value to default Arc shutter value
Motor Control
Arc Settings
Specifications
Camera Head
Image Sensor
1/6 CMOS 2MP
Active Array (H x V)
1920 x 1080
Image Area (mm)
2.73 x 1.55
Output Format
(Low Speed)
1080/30P
720/60P
VGA/120
Output Format
(High Speed)
1080/60P
720/90P
VGA/120
Output Type
DVI & USB
DVI & USB
USB
Minum illumination
S/N ratio
Environmental
Temperature
RH
Operational
0 to 60 C
90% non condensing
Storage
neg 20 to 85 C
non condensing
Weight
3 g
without cable