background image

Operating Instructions

SL VARITHERM DPA

HOM500327947Ien-7 • 17/12/2020

Содержание SL VARITHERM DPA

Страница 1: ...Operating Instructions SL VARITHERM DPA HOM500327947Ien 7 17 12 2020 ...

Страница 2: ...f contents 1 General 3 2 Use 3 3 Explanation of symbols for warnings and signal words 3 4 Safety information 3 5 Installation accessories 4 6 Technical Data 4 7 Installation 4 8 Connection 5 9 Commissioning 7 10 Maintenance 7 11 Troubleshooting 7 12 Deinstallation 7 13 Disposal 7 14 EU declaration of conformity 8 15 Further information and service 8 ...

Страница 3: ...connecting cable If a TAE is used the respective operating instructions must be complied with EC type examination certificates PTB 02 ATEX 1116 X with appendices and supplements in German and English as well as IEC Scheme Certificate IECEX PTB 07 0055X See http www intertec info 3 Explanation of symbols for warnings and signal words The safety information warns the user about risks and provide inf...

Страница 4: ...V AC Rated current in compliance with VDE 0298 max 10 A Ambient temperature 60 to 60 C Max permitted operating temperature 60 to 180 C Switching capacity of fault alarm AM 10 A 275 V AC Connecting cable Silicone hose cable notch and oil resistant 3 x 1 5 mm Connecting cable AM Silicone hose cable notch and oil resistant 5 x 1 0 mm Ø8 5 mm Material Seawater proof aluminium black anodized Mean Time ...

Страница 5: ...earance Illustration 3 Installation example vertical VARITHERM with TAE or TS with clearance Additional installation material such as rails or panels and also junction boxes are not included in the standard scope of delivery see Installation accessories Page 4 and must be ordered additionally 8 Connection INFO The device may only be connected up and secured by a trained person taking into account ...

Страница 6: ...efer also to DIN EN 60079 14 section 7 4 ATTENTION Never remove the adapter cable gland Illustration 4 Example heater with KLE connection CAUTION NOTICE Do not remove adapter cable connection to connect up the heater This would cause irreversible damage to the heater and this would mean that the explosion protection can no longer be warranted The illustration may deviate from the heater 1 2 L N PE...

Страница 7: ...ied out by the manufacturer in the factory All components have to be kept clean and free of dust and harmful substances that could lead to excessive temperature rise In the dust Ex area the applicable requirements of EN 60079 17 and EN 60079 19 must be complied with 11 Troubleshooting If the heater fails check the installation Carry out a continuity test on the heating circuit Pay attention to the...

Страница 8: ...N IEC 60079 1 2014 EN IEC 60079 31 2014 EN IEC 61000 6 4 2007 A1 2011 Harmonized Standard RoHS DIN EN IEC 63000 2019 Designation 0102 II 2 G Ex db IIC T6 T5 T4 T3 Gb II 2 D Ex tb IIIC T85 C T100 C T135 C T200 C Db PTB 02 ATEX 1116 X Neustadt January 28th 2020 Dipl Ing Martin Hess Managing Director 15 Further information and service If the information contained in this instruction manual should not...