Intertec Data Systems FL-ExVENT Скачать руководство пользователя страница 7

www.intertec.info

Operating Instructions Filter ventilator FL-ExVENT

COM155769227Ien-4

Page 7 / 8

INTERTEC-Hess GmbH · Raffineriestr. 8 · 93333 Neustadt/Donau · Germany · 

 +49 9445 9532-0 ·   [email protected]

Pump clean air: 

If the air is very dusty, you must use a filter upstream

Distance between rotating elements: 

The distance of the rotating elements in the axial and
radial direction must not be less than 2 mm from the
fan housing.

11

Deinstallation

Disassembly  may  only  be  carried  out  by  a  trained
person.

 DANGER

Risk of fatal injury from electric current!

If contact is made with live components, there is the risk
of fatal injury.

For this reason, switch off the voltage supply, secure
against being switched on again and check that no more
voltage is present.

Disconnect connection line from the clamps and from the
connection  socket,  disconnect  device  from  bracket  and
remove it.

12

Disposal

Disassemble  the  components  of  the  product,  taking  the
applicable  local  labour  protection  and  environmental
regulations  into  consideration  and  make  sure  that  the
components are recycled:

• Scrap metal

• Send plastic elements to recycling

• Sort other components according to their material

properties and dispose of them.

NOTICE

Environmental damage may be caused if
disposed of incorrectly!

Electrical scrap and electronics components are subject
to hazardous waste treatment and must only be
disposed of by certified specialists!

The  local  community  authorities  or  specialist  waste
disposal  companies  can  provide  information  on
environmentally friendly disposal.

13

EU declaration of conformity

The 

manufacturer, 

INTERTEC-Hess 

GmbH,

Raffineriestrasse  8,  93333  Neustadt/Donau,  Germany,
hereby declares in sole responsibility that the product

Product / Type designation:

FL-ExVENT

complies  with  the  provisions  of  the  following  directives
2014/34/EU  (ATEX),  2014/30/EU  (EMC),  2011/65/EU
(RoHS), 2012/19/EU (WEEE) complies with the following
standards,  harmonized  standards,  where  appropriate
and/or standardized documents:

EN 60079-0:2012+A11:2013

EN 60079-18: 2015

EN ISO 80079-36:2016

EN ISO 80079-37:2016

EN 14986:2017

Harmonized Standard (RoHS):

DIN EN IEC 63000:2019

Designation:

2572

II 2 G Ex h mb IIB+H2 T4 Gb

PTZ 18 ATEX 0050 X

Neustadt, August 18th, 2021

Dipl.-Ing. Martin Hess, Managing Director

14

Further information and service

If  the  information  contained  in  this  instruction  manual
should  not  be  sufficient  in  any  way,  then  INTERTEC
would  be  glad  to  be  at  your  disposal  to  provide  further
information and service.

Please  contact  your  INTERTEC  contact  person  or
directly contact

INTERTEC-Hess GmbH

Raffineriestr. 8

93333 Neustadt/Donau

Содержание FL-ExVENT

Страница 1: ...Operating Instructions Filter ventilator FL ExVENT COM155769227Ien 4 24 08 2021...

Страница 2: ...o Table of contents 1 Use 3 2 Explanation of symbols for warnings and signal words 3 3 Safety information 3 4 Technical Data 3 5 Installation 4 6 Connection 5 7 Commissioning 5 8 Troubleshooting 5 9 M...

Страница 3: ...must be adhered to are highlighted as follows DANGER DANGER This sign is warning about an extremely hazardous situation which if not heeded will lead to death or serious irreversible injury WARNING W...

Страница 4: ...2 x 252 44 Smooth the edges of the mounting cut out The FL ExVENT is inserted from the outside through the opening The clamping lugs can be perceptibly and audibly clicked into place in all four corne...

Страница 5: ...ent The fuse must be housed in the associated power supply unit or separately upstream The fuse rated current must be the same as or greater than the specified maximum working voltage of the electric...

Страница 6: ...ty fuse is triggered Device must be replaced Auxiliary fan blocked Use spacers to create space Temperature Temperature of suction medium is greater than 60 C thermal safety fuse is triggered The tempe...

Страница 7: ...OTICE Environmental damage may be caused if disposed of incorrectly Electrical scrap and electronics components are subject to hazardous waste treatment and must only be disposed of by certified speci...

Страница 8: ...e legally defined warranties and warranty periods of 24 months are applicable to our scope of supply and services You will find more detailed information in the manufacturer warranty from INTERTEC for...

Отзывы: