Operating Instructions Filter ventilator FL-ExVENT

Page 4 / 8

COM155769227Ien-4

INTERTEC-Hess GmbH · Raffineriestr. 8 · 93333 Neustadt/Donau · Germany · 

 +49 9445 9532-0 ·   [email protected]

Filter mat

G4

Only in delivery direction:

blowing in

Housing material

Stainless steel or GFK

Dimensions H x W x D

252 x 252 x 165 mm

*freeblowing;  in  conjunction  with  an  inlet/outlet  filter
series PFA 40000 with filter mat G4

 INFO

You will find the precise technical data for your
instrument on the label.

Type

Rated voltage / operating voltage

Rated power

Ø fan blade

Illustration 1: 

Label filter ventilator FL-ExVENT

5

Installation

NOTICE

Risk of Damage

When removing from the packaging and during
transport, the connection line must not be stressed or
bent.

Any installation location can be chosen for the filter fan.
The cut-out is optionally made in the wall or door.

Filter type

Cut-out size

(mm)

Overall

dimension of

filter (mm)

Depth (mm)

PFA 40000

223 x 223

252 x 252

44

• Smooth the edges of the mounting cut-out

• The FL-ExVENT is inserted from the outside through

the opening

• The clamping lugs can be perceptibly and audibly

clicked into place in all four corners by exerting slight
pressure

• Seal the cut-out circumferentially with silicon from

the inside of the housing

NOTICE

Risk of Damage

The protection class IP55 can only be guaranteed if the
installation position is correct and the seal is not
damaged.

The  operating  temperatures  must  be  adhered  to,
otherwise the thermal safety fuse will be triggered.

The connection line must be permanently installed up to
the  inlet  in  the  on-site  junction  box,  taking  the
permissible  bending  radius  =  5  x  outer  diameter  into
consideration.

The connection line must be connected in a housing that
complies  with  the  requirements  of  a  recognized  type  of
protection  in  accordance  with  EN  60079-0  section  1  if
the  connection  is  made  in  a  potentially  explosive
atmosphere.

The nameplate must always remain easily legible.

Fan propeller L175 Ø175
mm

Fan tubes inside L175 Ø180 mm

Tubes outside Ø186 mm

218 mm

Cut-out size 223.5 mm

Illustration 2: 

FL-ExVENT front view blowing out

Содержание FL-ExVENT

Страница 1: ...Operating Instructions Filter ventilator FL ExVENT COM155769227Ien 4 24 08 2021...

Страница 2: ...o Table of contents 1 Use 3 2 Explanation of symbols for warnings and signal words 3 3 Safety information 3 4 Technical Data 3 5 Installation 4 6 Connection 5 7 Commissioning 5 8 Troubleshooting 5 9 M...

Страница 3: ...must be adhered to are highlighted as follows DANGER DANGER This sign is warning about an extremely hazardous situation which if not heeded will lead to death or serious irreversible injury WARNING W...

Страница 4: ...2 x 252 44 Smooth the edges of the mounting cut out The FL ExVENT is inserted from the outside through the opening The clamping lugs can be perceptibly and audibly clicked into place in all four corne...

Страница 5: ...ent The fuse must be housed in the associated power supply unit or separately upstream The fuse rated current must be the same as or greater than the specified maximum working voltage of the electric...

Страница 6: ...ty fuse is triggered Device must be replaced Auxiliary fan blocked Use spacers to create space Temperature Temperature of suction medium is greater than 60 C thermal safety fuse is triggered The tempe...

Страница 7: ...OTICE Environmental damage may be caused if disposed of incorrectly Electrical scrap and electronics components are subject to hazardous waste treatment and must only be disposed of by certified speci...

Страница 8: ...e legally defined warranties and warranty periods of 24 months are applicable to our scope of supply and services You will find more detailed information in the manufacturer warranty from INTERTEC for...