Section 1

General Description

The TCIPI-4 

INTER

SECTOR 

Power Injector is a 

robust power supply designed specifically to power one to 

four TC-CK1-SBE 

INTER

SECTOR 

 sensors.  The 

TCIPI-4 receives the data from each TCIB card and injects 

24V DC on the Ethernet cable powering each 

INTER

SECTOR 

sensor.  Additionally, there is a 1 

amp slow blow fuse in series with each 

INTER

SECTOR 

sensor that protects against short 

circuits that could cause a unit to stop functioning.

Section 2

Installation

1.  Attach the TCIPI-4 at the desired location in the 

 

cabinet utilizing the predrilled hole locations in the 

 

mounting plate.

 WARNING: 

 Ensure incoming power source to

 

the TCIPI-4 is off prior to connecting any 

 

wires to the device and that the power switch 

 

located on the printed circuit board (PCB) is in 

 

the off position.

2.  Connect 110V AC power source to the TCIPI-4 wire 

 

harness (Fig. 1).

FIGURE 1

TCIPI-4 Printed Circuit Board Layout & Wiring Diagram

3.  Plug each Ethernet cable into the Operational Plug on

 

each TCIB Card and then into the 4 Port Ethernet 

 

Modular Jack located on the TCIPI-4 PCB marked 

 

“FROM TCIB”.

 NOTE: 

 For convenience, four 36” long 

 

Ethernet cables in four different colors are 

 

provided to ease identifying each 

 

TCIB-To-TCIPI-4 connection in the cabinet. 

4.  Plug each of the Ethernet cables from each 

 

INTER

SECTOR 

Sensor into the 4 Port 

 

Ethernet Modular Jack located on the TCIPI-4 PCB 

 

marked “TO INTERSECTOR” ensuring they are paired 

 

properly with each TCIB Card (Fig. 2).

FIGURE 2

 

FROM TCIB 

TO INTERSECTOR

  Ch1  To Ch1

  Ch2  To Ch2

  Ch3  To Ch3

  Ch4  To Ch4

5.  Turn on incoming power source to the TCIPI-4, wait 

 

10 seconds and then flip the power switch on the 

 

PCB to the ON position (Fig. 1).  The Red LED will 

 

illuminate indicating the device is functioning 

 properly.

Section 3

Technical Data

Model............................................... TCIPI-4

Input Power Rating......................... 90 - 130V AC

Operating Frequency....................... 47-63 Hz

Input Fusing..................................... Internal on both L & 

 

N lines

Internal Power Supply 

Power Rating................................... 24V @ 10.4 Amps

Internal Power Supply

Constant Output Voltage................ 24V ± 1 volt

Outputs to Intersector Sensor........ typical 200mA each

Fuses............................................... Slow Burn 1 Amp each

Temperature Range........................ -40°F to 185°F 

 

(-40°C to 85°C)

!