TCIPI-4
INTER
SECTOR
Power Injector
INSTALLATION INSTRUCTIONS
7898 Zionsville Road
Indianapolis, Indiana 46268
Telephone: (317) 842-2545
www.mssedco.com
Page 1
(/MANU) TCIPI-4v0917
Section 1
General Description
The TCIPI-4
INTER
SECTOR
Power Injector is a
robust power supply designed specifically to power one to
four TC-CK1-SBE
INTER
SECTOR
sensors. The
TCIPI-4 receives the data from each TCIB card and injects
24V DC on the Ethernet cable powering each
INTER
SECTOR
sensor. Additionally, there is a 1
amp slow blow fuse in series with each
INTER
SECTOR
sensor that protects against short
circuits that could cause a unit to stop functioning.
Section 2
Installation
1. Attach the TCIPI-4 at the desired location in the
cabinet utilizing the predrilled hole locations in the
mounting plate.
WARNING:
Ensure incoming power source to
the TCIPI-4 is off prior to connecting any
wires to the device and that the power switch
located on the printed circuit board (PCB) is in
the off position.
2. Connect 110V AC power source to the TCIPI-4 wire
harness (Fig. 1).
FIGURE 1
TCIPI-4 Printed Circuit Board Layout & Wiring Diagram
3. Plug each Ethernet cable into the Operational Plug on
each TCIB Card and then into the 4 Port Ethernet
Modular Jack located on the TCIPI-4 PCB marked
“FROM TCIB”.
NOTE:
For convenience, four 36” long
Ethernet cables in four different colors are
provided to ease identifying each
TCIB-To-TCIPI-4 connection in the cabinet.
4. Plug each of the Ethernet cables from each
INTER
SECTOR
Sensor into the 4 Port
Ethernet Modular Jack located on the TCIPI-4 PCB
marked “TO INTERSECTOR” ensuring they are paired
properly with each TCIB Card (Fig. 2).
FIGURE 2
FROM TCIB
TO INTERSECTOR
Ch1 To Ch1
Ch2 To Ch2
Ch3 To Ch3
Ch4 To Ch4
5. Turn on incoming power source to the TCIPI-4, wait
10 seconds and then flip the power switch on the
PCB to the ON position (Fig. 1). The Red LED will
illuminate indicating the device is functioning
properly.
Section 3
Technical Data
Model............................................... TCIPI-4
Input Power Rating......................... 90 - 130V AC
Operating Frequency....................... 47-63 Hz
Input Fusing..................................... Internal on both L &
N lines
Internal Power Supply
Power Rating................................... 24V @ 10.4 Amps
Internal Power Supply
Constant Output Voltage................ 24V ± 1 volt
Outputs to Intersector Sensor........ typical 200mA each
Fuses............................................... Slow Burn 1 Amp each
Temperature Range........................ -40°F to 185°F
(-40°C to 85°C)
!
ETHERNET MODULAR JACK