Interroll Diverter SH 1500
Installation
40
Version 1.0 (06/2022) en
Translation of original operating instructions
Module conveyor curve -
lateral diverter
2
5
2
7
6
4
3
2
1
1
Diverter
5
Connecting plate
2
Washer
6
Torx screw (M8x20)
3
Torx screw (M8x12)
7
Nut
4
Module conveyor curve
A connection is possible only at the diverter side without cable output.
4
Position the modules to be connected (1, 4) in such a way that the side profiles are aligned.
4
Align the top edges of the modules by using the height-adjustable feet of the supports.
4
Check horizontal alignment with a spirit level or rotation laser.
4
Secure the adjusted height.
4
Use the connecting plate (5) to connect the two modules at the underside of the side profile
of the diverter (1) and on the right and left at the end plate of the module conveyor curve (4)
with screws (3, 6), washers (2) and nuts (7).
4
Fasten the module torsion-free, e.g., by anchoring it to the floor or to adjacent components.