14 von 38
Version 2.0 (12/2019) Online
Translation of the original operating manual
Product information
Temperature protection
The brake chopper resistor is temperature-controlled. If, due to specific application properties (e. g. high conveying
weight or high conveying speed), the brake chopper resistance is frequently switched, the DriveControl switches
off when it becomes too hot (approx. 90 °C inner temperature). If temperature protection is activated, this state is
indicated by the LEDs and no start signal will be transmitted to the RollerDrive. When the DriveControl has cooled
down, the RollerDrive restarts automatically when a signal is pending. The DriveControl cools down quicker if it is
mounted on a flat surface, ideally metal.
NOTE
DriveControl failure from overheating
¾
Do not perform a voltage reset when temperature protection is active.
Содержание AdControl