Interplast Green Line 120 Скачать руководство пользователя страница 1

 

 

 

 
 

 

 

 

 

 
 

 
 

 
 
 

 

Technical Bulletin - Solar water heaters installation and 

maintenance manual  

 

 

Interplast Green Line 

Interplast Green Line 

 

Interplast Green Line Plus 

 

801 – Strip 1,25 m

2

 

120 – Strip 1,5 m

2

 

150 – Strip  2 m

2

 

170 – Strip 2 m

2

 

200 – Strip 2 m

2

 

270 – Strip 2,5 m

2

 

300 – Strip 2 x 2m

2

 

 

170 – Full Face 2 m

2

 

202 – Full Face 2,2 m

2

 

205 – Full Face 2,5 m

2

 

270 – Full Face 2,5 m

2

 

300 – Full Face 2 x 2m

2

 

 

 
 

100L 
150L 

200L 

 

 

 

 

 

 

 

 

5 years

 Guarantee 

 

 

The Fully Integrated – Certified Solar Proposal!

 

 

Содержание Green Line 120

Страница 1: ...erplast Green Line Plus 801 Strip 1 25 m2 120 Strip 1 5 m2 150 Strip 2 m2 170 Strip 2 m2 200 Strip 2 m2 270 Strip 2 5 m2 300 Strip 2 x 2m2 170 Full Face 2 m2 202 Full Face 2 2 m2 205 Full Face 2 5 m2...

Страница 2: ...Tube 8 2 4 Hot water cylinder 9 2 5 Foldable Bracket for Terrace 10 2 6 Tile Roof Mounting System 12 3 Basic Manual for Solar Water Heater Installation 13 3 1 Foldable Bracket for Terrace Interplast G...

Страница 3: ...p 120 L 107L Interplast Green Line 150 Selective Collector 2 m2 Strip 150 L 132L Interplast Green Line 170 Selective Collector 2 m2 Strip 170 L 152L Interplast Green Line 200 Selective Collector 2 m2...

Страница 4: ...areas Back from anodized aluminum sheet for high corrosion resistance humid climates coastal areas 30 mm thick rock wool insulation on the back and 15mm thick on the sides for higher performance at l...

Страница 5: ...um oxides Material Width Side insulation 15 mm Rock Wool 15 mm Rock Wool 15 mm Rock Wool Material Width Back insulation 30 mm Rock Wool 30 mm Rock Wool 30 mm Rock Wool Soldering Absorber Copper pipes...

Страница 6: ...polyurethane and further compressed at a temperature to achieve uniform density 52 kg m2 throughout the length and width Insulation thickness of 30 mm on the back and 15mm on the sides for higher per...

Страница 7: ...5 mm Compressed Polyurethane 52kg m3 15 mm Compressed Polyurethane 52kg m3 Material Width Back insulation 30 mm Compressed Polyurethane 52kg m3 30 mm Compressed Polyurethane 52kg m3 30 mm Compressed P...

Страница 8: ...double coated glass tube Due to special geometry shape of the absorber maximal absorption of solar energy is achieved Vacuum Tube Length of Vacuum tube Length of absorber 1800 mm 1720 mm Inner outer...

Страница 9: ...n Tank 15 bar EN 12976 1 4 1 6 Maximum Working Pressure for the Jacket Exchanger 3 5 bar Test Pressure for the Jacket Exchanger 5 bar EN 12976 1 2006 4 1 6 Maximum Working Temperature of the Main Tank...

Страница 10: ...manual Interplast Green Line 2 5 Foldable Bracket for Terrace Base Dimensions for 1 collector Height Width Surface Weight m m m2 Kg 1 5 1 00 1 5 16 2 00 1 00 2 00 19 2 00 1 25 2 00 19 Base Dimensions...

Страница 11: ...ase Height m Distance Between Vertical Legs m 80 1 2 0 95 1 2 0 98 0 82 0 76 80 1 5 1 5 1 0 1 55 1 15 0 76 120 1 5 1 5 1 0 1 55 1 15 0 94 170 2 0 1 6 1 3 1 62 1 22 0 94 300 2 x 2 0 4 0 1 6 1 3 1 62 1...

Страница 12: ...the factor and add ca 0 1m due to the connection required for the 2 collectors Dimensions of base stand for tiled roof Tank Volume L Collector Surface m2 A B C D E Collector Height m Collector Width...

Страница 13: ...y should be avoided 3 During storage and before installation the solar collectors should not be exposed to sun light 4 The closed circuit of the solar system should be filled with water and add the an...

Страница 14: ...w before starting the base installation Special care should be taken to the right ground support 1 Open the package and put the collector in vertical position as picture 1 2 Pull the base as indicated...

Страница 15: ...the solar panels Place the screws and tight the tank to the base Place the two angle pairs which are anchoring is the base as it is seen in the scheme The vertical angles are placed in the legs wheth...

Страница 16: ...stallation and maintenance manual Interplast Green Line 3 2 Terrace base Interplast Green line Plus Vacuum Tube Read carefully the instructions below before starting the base installation Special care...

Страница 17: ...Strip Full face Collate the tile roof base as it is seen in pic 7 After mark the tiles in order to make the holes always in the tile s hump Fix the base with the special moles which are included in t...

Страница 18: ...18 Technical bulletin Solar water heaters installation and maintenance manual Interplast Green Line 3 4 Tile Roof Base Interplast Green Plus...

Страница 19: ...19 Technical bulletin Solar water heaters installation and maintenance manual Interplast Green Line...

Страница 20: ...cold and hot water Correspondingly we tap the two others with collector tap 22 2 After fill the circuit with the water glycol mixture from the upper side of the tank until is fully filled Position 1 N...

Страница 21: ...the tank by opening a faucet of the residence in hot and wait till a stabile water flow comes After continue with the filling of the closed circuit Empty the antifreeze liquid in the wished proportio...

Страница 22: ...om water Connection parts of the electric heater and thermostat 1 Screws for the tank s flange 2 Electric heater with thermostat 3 Connection for GROUND 4 Safety thermostat 5 Terminals 6 Temperature a...

Страница 23: ...connections The electric resistance is out of order 1 Check the thermostat connections according the diagram 2 Check that the table security is not turned off 3 Check the selected thermostat temperatu...

Отзывы: