background image

 

Page 14 

AIR CONDITIONER CARE 

Your new air conditioner is designed to give you many years of dependable service. This section tells you how to 

clean and care for your air conditioner properly. Call your local authorized dealer for an annual checkup. Remember, 

the cost of this service call is your responsibility. 

__________________________________________ 

Cleaning the Air Filter 

The air filter is removable for easy cleaning. A clean 
filter helps remove dust, lint, and other particles from 
the air and is important for best cooling and operating 
efficiency. Check the filter every 3 weeks to see if it 
needs cleaning, or when the filter light is illuminated. 
 

NOTE:

 Do not operate the air conditioner without the 

filter in place. 
 
1.  Turn off the air conditioner. 
2.  Remove air filter

.

 

 

 
3.  Use a vacuum cleaner to clean air filter. If air filter 

is very dirty, wash it in warm water with a mild 
detergent. Do not wash air filter in the dishwasher 
or use any chemical cleaners. Air dry the filter 
completely before replacing to ensure maximum 
efficiency. 

4.  Install the  filter. 

Cleaning the Front Panel 

1.  Turn off the air conditioner 
2.  Remove the air filter and clean it separately. See 

Cleaning the Air Filter. 

3.  Wipe the front panel with a soft damp cloth. 
4.  Air dry front panel completely. 

 

 
__________________________________________ 

Repairing Paint Damage of Outside 

Case 

Check once or twice a year for paint damage. This is 
very important, especially in areas near oceans or 
where rust is a problem. If needed, touch-up with a 
good grade enamel paint. 
 

NOTE: 

To reduce paint damage during the winter, 

install a heavy duty cover over the air conditioner 
cabinet. 

__________________________________________

 

Annual Maintenance 

Your air conditioner needs annual maintenance to help 
ensure steady, top performance throughout the year. 
Call your local authorized dealer to schedule an 
annual checkup. The expense of an annual inspection 
is your responsibility

4.    Replace air filter by sliding filter down into filter 

door and closing filter door. 

 

NOTE

: Never use hot water over 104 °F to clean the 

air filter. Never attempt to operate the unit without the 
air filter. 
 
 

 

 

 
 
 
 
 
 
 
 
 
 

Содержание WA410YER

Страница 1: ...WINDOW AIR CONDITIONER USER MANUAL 950 0270 revA 9 30 2019 FOR MODELS COOLING BTU h WA46YER 6 050 WA48YER 8 000 WA410YER 10 200 WA412YER 12 100...

Страница 2: ...rations and usage Please read carefully the sections corresponding to the specific model you have and keep the manual in a safe place for reference The refrigerant used in your window air conditioner...

Страница 3: ...Page 2 INSTALLATION REQUIREMENTS Tools and Parts...

Страница 4: ...conditioner can be installed without the accordion panel if needed to fit in a narrow window See Window Opening dimensions All supporting parts must be secured to firm wood masonry or metal Follow the...

Страница 5: ...l codes and ordinances Power Supply Cord NOTE Your unit s device may differ from the ones shown This room air conditioner is equipped with a power supply cord required by UL This power supply cord con...

Страница 6: ...to the air conditioner Note For some models the top mounting rail might be pre installed to the unit skip this step if it is installed Install the Accordion Panels Hold the accordion panel in one han...

Страница 7: ...itioner in window Check that lower rail of air conditioner is behind and against back side of window sill Maintain a firm grip on the air conditioner cabinet Lower window sash to hold cabinet in place...

Страница 8: ...oom Install the R1 Hardware In order to minimize air leaks and ensure optimal insulation it is necessary to install the included R1 hardware to the side curtain Follow the instructions below After the...

Страница 9: ...thoroughly familiarize yourself with the control panel and remote as shown below and all its functions then follow the symbol for the functions you desire The air conditioner can be controlled by the...

Страница 10: ...button After Fan operates for 250 hours this indicator will be delighted Clean the filter when the light is on 5 Delay 1 24 Hrs button Press this button to set the TIMER ON and TIMER OFF The setting i...

Страница 11: ...F In timer mode the time will be increased or decreased by 1 hour 7 Display The display will show the following o ENERGY SAVER FAN ONLY COOL show the room temp o TIMER shown the setting timer in the f...

Страница 12: ...e controller either move these appliances or consult your local dealer Replacing Batteries The remote control is powered by two AAA alkaline batteries housed in the back of the remote Do not use recha...

Страница 13: ...e fan speed The auto Fan can t be set in this mode o Energy Saver In this mode air conditioner operates the Energy Saver mode The energy saver indicator will be on Press Fan Speed button can adjust th...

Страница 14: ...nds Air Directional Louvers Normal Sounds When your air conditioner is operating normally you may hear sounds such as o Droplets of water hitting the condenser causing a pinging or clicking sound The...

Страница 15: ...dry the filter completely before replacing to ensure maximum efficiency 4 Install the filter Cleaning the Front Panel 1 Turn off the air conditioner 2 Remove the air filter and clean it separately See...

Страница 16: ...t least 3 minutes after turning the unit off before trying to restart the air conditioner Air conditioner power supply cord trips Reset button pops out Disturbances in your electrical current can trip...

Страница 17: ...to the outside are open Close all windows and doors The Vent control is set to open on some models Push the Vent control to CLOSED for maximum cooling and or heating The temperature set point or Ther...

Страница 18: ...840 1000 Plug Type LCDI 5 15P 5 15P 5 15P 5 15P Power Cord Rating amps 10 13 13 15 Power Cord Length ft 6 6 6 6 Refrigerant Charge R410a oz 14 82 16 2 20 46 24 69 Max dbA Level Indoor Outdoor 65 67 6...

Страница 19: ...LABOR IS NOT COVERED 2 OUT OF CARTON ISSUES MUST BE REPORTED WITHIN ONE DAY 3 PARTS ARE COVERED FOR 1 YEAR 4 COMPRESSORS ARE COVERED FOR 1 YEAR 5 NORMAL WEAR AND TEAR IS NOT COVERED Additional claims...

Отзывы: