There should not be any heat source or steam 
near the unit.
There should not be any obstacles blocking 
air circulation.
Locate where there is good air circulation in the room.
Water drainage must be considered when locating the unit.
Ensure the dimensions indicated by arrows from the 
wall, ceiling, floor and other obstacles are observed.
There should not be any direct sunlight. If unavoidable, 
sunlight prevention should be taken into consideration.

1. Secure the mounting plate level to 
    structural wall supports.
    Use a level to ensure the mounting
    plate is leveled, so condensate can
    drain properly.
2. If the wall is made of brick, concrete 
    or the like, drill eight (8) 0.2" diameter 
    holes in the wall. Insert Clip anchor for 
    appropriate mounting screws.
3. Secure the mounting plate on the wall 
    with wall anchors or proper mounting 
    screws.

Use the mounting plate (packaged in the back 
of the indoor unit) as the template.

(Dimensions are in inches unless otherwise stated)

1. Determine hole positions according  to left and right 
    side of the installation plate. The hole center is obtained 
    by measuring the distance as shown in the diagram above. 
2. Drill the wall hole with a 

φ

3.7" hole-core drill.

3. Drill the wall hole at either the right or the left and the 
    hole must be slightly slanted to the outdoor side.
4. Always use wall hole conduit when drilling metal grid, 
    metal plate or the like.
5. Wall

 

sleeve can now be inserted into the hole from the inside. 

    We recommend the sleeve to be approximately 3/16” longer 
    than the wall thickness - cut as necessary.

1. For the left-hand and right-hand installation, 
    remove the pipe cover from the side panel.    
2. For the rear-right-hand and rear-left-hand 
    installation, install the piping as shown. 
3. Bundle the tubing, connecting cable, and 
    drain hose with tape securely,  as 
    shown in Figure on the right.
    
    Do not restrict water from draining out of drain pan.
       

1. Run the drain tubing sloping downward. 
    Do not install the drain hose as illustrated 
    in Figures.
2. When connecting extension drain hose, 
    insulate the drain tubing with tape and 
    maintain a downward slope.

Connect the indoor unit first, then the 
outdoor unit. 
Be careful not to let the drain hose slack.
Insulate both suction and liquid pipes. 
Be sure that the drain hose is located at 
the lowest side of the bundle. Locating at 
the upper side can cause drain pan to 
overflow inside the unit.
Run the drain hose sloping downward to 
drain the condensed water smoothly.

Anchor the outdoor unit with a bolt and nut (3/8") 
tightly and horizontally on a concrete or rigid mount.

Outdoor unit dimension
          inch (L1xHxW1)

L2(inch) W2(inch)

24.6

23.2

14.4

13.1

Mounting dimensions

40x38x13.6

35.4x33.9x12.4

1. Pass the piping through the hole in the wall.
2. Hook the indoor unit onto the upper portion 
    of installation plate(Engage the indoor unit with 
    the upper edge of the installation plate). Ensure 
    the hooks are properly seated on the installation 
    plate.
3. Piping can be made easier by lifting the indoor 
    unit with a cushioning (spacing) material between 
    the indoor unit and the wall. Remove after 
    completing the indoor installation to wall plate.
4. Press the lower left and right side of the unit 
    against the installation plate until hooks 
    engages with the their slots.
5. Indoor unit is now installed. It should be plumb, 
    level and flush with the wall. Ensure that the line set 
    stubs are completely through the wall. 
    Also check that the wall is plumb. The unit must be 
    level and plumb for proper condensate removal. 
6. Check the drain hose, Observe that the condensate 
    drain pipe does not curve upward and is in the lower 
    part of the pipe bundle. 

INSTALLATION AND MAINTENANCE 

MANUAL

FOR MODELS: MSM30H46ZI, MSM36H44ZI
                          30H46ZMI, 36H44ZMI

SELECT IDEAL LOCATION

Indoor  unit

WALL HOLE - REAR CABLE & DRAIN  

Outdoor  unit

Installation  of  the  outdoor unit

INDOOR  UNIT MOUNTING PLATE

CONNECTING LINE SET AND DRAIN TUBING 

NOTE:

NOTE:

Fit the Mounting Plate

Line Set  installation

Drainage

CAUTION

Indoor unit installation

1

 

The mounting wall should be strong and solid
enough to prevent vibration. 

There should not be any obstructions for the discharge air.

Ensure the dimensions indicated by arrow from a wall 
fence or other obstacles are maintained.

I

N
D
O
O

U
N

I

Mounting Plate

Remote Control
Remote Control Holder

Batteries for Remote Control (2  AAA)

Operation Manual     

The following items are necessary for the installation of the ductless mini splits.

Par ts included with unit

Description

NOTE

:

          The seriousness is classified by the following indications.

This symbol indicates the possibility of death,  serious injury or property damage.

1)  This equipment must be properly 

or personal injury and erratic operation may occur.

2)  Do not install the unit at place where leakage of flammable gas may occur. In case gas leaks and 
     accumulates at surrounding of the unit, it may cause fire.

3)  Carry out drainage piping as mentioned in installation instructions. If drainage is not perfect, water 
      may enter the room and damage the furniture.

grounded 

1)  Install according to this installation instruction. If installed improperly, it may cause property 
      damage, water leakage, electrical shock and fire damage.
2)  Use the included accessories and specified parts for installation, otherwise, it cause collateral damage.
      
3)  Install outdoor unit on a firm solid base capable of supporting the weight of the unit. 
     The indoor unit must be installed on a wall capable of supporting the weight of the unit.
4)  The electrical installation must follow all local and national codes by a certified installer. Supply power
     must be from a protected circuit. The supply circuit must be used with an outdoor approved disconnect 
     box.
5)  Use only the specified wire or cable. All connections must be secured to prevent external 
     pulling of wires to terminal connections, this may cause fire or personal harm.
6)  Wire routing must be arranged so that control board cover is fixed properly. If control board

cover is not fixed perfectly, it will cause fire or electrical shock.

     

   

 

 

   

 

 

   

 

7)  When installing the line set (piping) take precautions not to let air and any foreign materials from 
     entering the system, this will cause lower capacity, abnormal pressure and damage to the compressor.

SAFETY PRECAUTIONS

WARNING/CAUTION

CAUTION

WARNING

      Please read this installation document completely before installing the product.
      Installation must be performed by a certified installer and all electrical wiring must meet local and 
      national electrical codes. 
      Contact an authorised service technician for repair, maintenance or installation of this unit.
      

The design and specifications are subject to change without prior notice for product improvement. 

      Consult with the sales agency or manufacturer for details.
   

All the pictures in the instructions are for explanation purposes only. 

      The actual dimensions and shape may have been revised.
      

 

Correct orientation 
of Mounting Plate

MINI-SPLIT

950-0182revC

November 27, 2013

6" or more

5" or m

ore

5" o

r m

ore

90.6" or more

12" o

r more

24" o

r m

ore

12" o

r m

ore

2

4

" o

r m

o

re

79" o

r mo

re

Wall Anchors

Indoor

unit

Installation Manual

Plastic Drain Connection 

• Refrigerant line set: Flared connection only, suitable for R410A with both lines insulated. 
  Max length for connection see product label on outdoor unit.
• High voltage interconnect wiring: 16AWG wiring from outdoor unit to indoor unit for power and 
  control.
• 5/8" drain tubing as necessary.
• Wall Sleeve
• Sealant
• 2" wide tape
• Main system breaker: Sized per unit requirements (See product label on the outdoor unit)
• Refrigerant: R410A required for additional line set Charge - See product label on the outdoor unit.
• Mounting hardware, condenser pad, etc.
 

Left wall hole

4.7" or more

  from  the wall

4.7" or more  
from the wall

5.9" or more
from the ceiling 

Hook Mountings

Indoor unit outline

Right wall hole

57.1"

40.3"

16.8"

16.6"

7.5"

2.8"

2.8"

2.8"

1

3

.4

"

0

.9

8

"

0

.8

"

6

.8

5

"

1.4"

1.26"

1.26"

12.5"

12.5"

1.4"

3.7

"

2

.1

6

"

2

.1

6

"

Low Ambient Controller is included for use in Server Rooms or in Commercial applications. 

Outdoor

unit

O p t i o n a l C o n t r o l s a n d C o m p o n e n t s

• Condensate Pump: 
  

• Decorative Channel: Plastic-Duct

 

• Wall brackets: Our Catalog# BR-440L 
  for up to 440 lbs.

Siccom  P/N DE05LUA720 (4100123)

  or P/N D05LUB100 (4100130)

Detail of cover removal