background image

- 15 - 

 

 
 

SPECIFICATIONS 

 

Model 

DH450SM 

DH470SM 

DH470SMP 

Capacity 

50 Pints/Day 

70 Pints/Day 

70 Pints/Day 

Tank Size 

1.6 gal 

1.6 gal 

1.6 gal 

Rated Frequency 

60 Hz 

60 Hz 

60 Hz 

Rated Voltage 

115 V 

115 V 

115 V 

Rated Current  

4.7 A 

6.9 A 

6.9 A 

Rated Input 

520 W 

740 W 

720 W 

Plug Type 

5-15P 

5-15P 

5-15P 

Refrigerant (R410A) 

7.76 OZ

  

9.17 OZ 

9.17 OZ 

Net Weight 

36.3 LBS 

39.6 LBS 

40.7 LBS 

EEV 

1.85 L/kWH 

1.85 L/kWH 

1.85 L/kWH 

HP.PSIG 

540 PSI 

540 PSI 

540 PSI 

LP.PSIG 

300 PSI 

300 PSI 

300 PSI 

 
 

Model 

DH470SMA 

 

DH470SMPA 

Capacity 

70 Pints/Day 

 

70 Pints/Day 

Tank Size 

1.6 gal 

 

1.6 gal 

Rated Frequency 

60 Hz 

 

60 Hz 

Rated Voltage 

115 V 

 

115 V 

Rated Current  

6.5 A 

 

6.5 A 

Rated Input 

690 W 

 

690 W 

Plug Type 

5-15P 

 

5-15P 

Refrigerant (R410A) 

7.76 OZ 

 

8.29 A 

Net Weight 

37.5 LBS 

 

42.8 LBS 

EEV 

2.0L/kWH 

 

2.0 L/hWH 

HP.PSIG 

540 PSI 

 

540 PSI 

LP.PSIG 

300 PSI 

 

300 PSI 

 
 

 

NOTE: 

Product specification subject to change without notice.

 

 
 
 
 
 
 
 
 

Содержание DH450SM

Страница 1: ...DEHUMIDIFIER USER MANUAL 950 0188 revE 04 25 17 For Models DH450SM DH470SM DH470SMP DH470SMA DH470SMPA...

Страница 2: ...slightly different from the ones described in this manual but will not affect proper operation and usage Please read carefully the sections corresponding to the specific model you have and keep the m...

Страница 3: ...icates the possibility of injury or damage to property only WARNING Follow all grounding and electrical requirements as shown on page 4 Turn unit OFF and disconnect power cord from receptacle prior to...

Страница 4: ...place water tank after emptying to prevent water damage to property and unit Do not operate unit with wet hands Close all doors and windows to the room where the dehumidifier is to be operated Dehumid...

Страница 5: ...dedicated circuit serving only this appliance For your personal safety this appliance must be grounded This appliance has a power supply cord with a grounding plug To minimize possible shock hazard t...

Страница 6: ...ont 1 Control panel 2 Air intake grill 3 Air outlet grill 4 Air filter behind the grill 5 Water bucket 6 Handle both sides Rear 1 Continuous drain hose outlet 2 Caster 3 Power cord and plug 4 Band use...

Страница 7: ...eration NOTE Make sure the pump drain hose is installed and the continuous drain hose is removed before the pump operation is activated CAUTION DO NOT PUMP TO ANY AREA WHERE THE TEMPERATURE IS LESS TH...

Страница 8: ...Shows the room humidity level in a range of 30 RH to 90 RH with a 5 accuracy Shows the desired humidity level 35 85 while being adjusted Shows the AutoStart Stop time 0 24 while being adjusted Error C...

Страница 9: ...Filter Light AUTO RESTART If the unit turns off unexpectedly such as a power outage it will resume operation with the previous settings when the power resumes FAN SELECTION Select two fan speeds TANK...

Страница 10: ...uables are stored Use the dehumidifier in a basement to help prevent moisture damage The dehumidifier must be operated in an enclosed area to be most effective Close all doors windows and other outsid...

Страница 11: ...the unit The bucket must be in the proper position for the dehumidifier to operate 6 If on the unit will resume operation once the bucket is in the proper position NOTES o When removing the bucket do...

Страница 12: ...e two screws included 5 Install the female threaded end of the water hose garden hose not included into the adaptor 6 Make sure the hose is secure so there are no leaks 7 Lead the water hose to a floo...

Страница 13: ...loud when it starts working for the first 3 5 minutes 9 Select the desired humidity setting and fan speed on the unit to start normal operation 10 To remove pump drain hose press the hose in to relea...

Страница 14: ...250 hours of operation or more often if necessary To remove Remove the bucket grasp the filter edge and pull it straight down and out To clean Clean the filter with warm soapy water Rinse and let the...

Страница 15: ...sources i e clothes dryer etc Look for sources of humidity and correct if necessary Ambient temperature to low Moisture removal is best at higher room temperature Lower room temperatures will reduce t...

Страница 16: ...ght 36 3 LBS 39 6 LBS 40 7 LBS EEV 1 85 L kWH 1 85 L kWH 1 85 L kWH HP PSIG 540 PSI 540 PSI 540 PSI LP PSIG 300 PSI 300 PSI 300 PSI Model DH470SMA DH470SMPA Capacity 70 Pints Day 70 Pints Day Tank Siz...

Страница 17: ...ovides free replacement of defective parts only Labor is not covered under this warranty Replacement as a result of normal wear and tear is not covered under this warranty Additional claims are exclud...

Отзывы: