SPECIFICATIONS 

MODEL 

DH45 DH65 

Capacity 

45 PINTS/DAY 

65 PINTS/DAY 

Rated Frequency 

60 Hz 

60 Hz 

Rated Voltage 

115VAC 

115VAC 

Rated Current Input 

5.5 A 

9.0 A 

Rated Input 

640W 

1050 W 

Refrigerant/Wt 

R22/ .56 LB 

R22/ .62 LB 

Weight(net) 

44.3 LBS 

50.3 LBS 

Sizes(WxDxH) (in) 15.2x14x24 15.2x14x24 

HP. PSIG 

319 PSI 

377 PSI 

LP. PSIG 

145 PSI 

145 PSI 

 

 

 

PRODUCT SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

             -11-

 

Содержание DH45

Страница 1: ...Dehumidifier Users manual For Models DH45 DH65 950 0014 revF Nov 7 2007...

Страница 2: ...ifier 2 Do not modify or otherwise defeat the plug 3 The appliance shall be installed an operated in accordance with National Electrical Code regulations 4 Do not operate the machine when the ambient...

Страница 3: ...mbol indicates the possibility of injury or damage to property only WARNING Follow all grounding and electrical requirements on page 3 Disconnect power cord from receptacle prior to servicing or clean...

Страница 4: ...r emptying to prevent water damage to property and unit Do not operate unit with wet hands Remove power from unit when it is to be cleaned Close all doors and windows to the room where the dehumidifie...

Страница 5: ...inimize possible shock hazard the cord must be plugged into a mating grounding type wall receptacle and grounded in accordance with the National Electrical Code latest edition and all local codes and...

Страница 6: ...Y TO PERSONS READ THE IMPORTANT SAFETY INSTRUCTIONS BEFORE OPERATING THIS APPLIANCE IMPORTANT When unit is first plugged in or after a power outage there will be approximately a 2 minute delay before...

Страница 7: ...0 60 or 70 is illuminated it shows the corresponding Relative Humidity that has been chosen CONT Continuous Dehumidifying Indication Light When this light is on it shows the unit is in the continuous...

Страница 8: ...ndication light for this speed is illuminated The unit will start to operate and the air outlet will be in the Medium level LOW Press the FAN SPEED button until the light for this speed is illuminated...

Страница 9: ...operating the condensed water might drop to the base plate it is recommended to take out the bucket for emptying when the unit has stopped operating for some time to prevent the condensed water from s...

Страница 10: ...Rinse and let dry Once completely dry re install filter CLEANING INSIDE THE UNIT After removing the air filter clean the coil on the inside of the unit with a soft brush to remove any dirt that may h...

Страница 11: ...Airflow is restricted Make sure intake louvers aren t blocked and have proper clearances Doors and windows may not be closed tightly Check that doors windows and other openings are securely closed Hum...

Страница 12: ...n first turned on High temperatures of the heat exchanger may cause strange odors Stains in the water tank Sometimes stains are left due to factory testing Unit only works in High mode When the ambien...

Страница 13: ...Rated Voltage 115VAC 115VAC Rated Current Input 5 5 A 9 0 A Rated Input 640W 1050 W Refrigerant Wt R22 56 LB R22 62 LB Weight net 44 3 LBS 50 3 LBS Sizes WxDxH in 15 2x14x24 15 2x14x24 HP PSIG 319 PS...

Страница 14: ...tration period This warranty provides free replacement of defective parts only Labor and replacement as a result of normal wear and tear are not covered under this warranty Additional claims are exclu...

Отзывы: