background image

484 01 3700 01

December 2011

INSTALLATION INSTRUCTIONS

Cased N Coil, Horizontal

ENH4X

NOTE

: Read the entire instruction manual before starting

the installation.

TABLE OF CONTENTS

PAGE

SAFETY CONSIDERATIONS

1

. . . . . . . . . . . . . . . . . . . . . . . .

INTRODUCTION

2

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

INSTALLATION

2

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Horizontal Right and Left with Pan Extension

3

. . . . . .

Furnace Attachment

3

. . . . . . . . . . . . . . . . . . . . . . . . . . . .

Horizontal Attic

4

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Horizontal Crawl Space

4

. . . . . . . . . . . . . . . . . . . . . . . . .

Refrigerant Lines

4

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Connect Refrigerant Liquid and Suction Lines

4

. . . . . .

Connect Condensate Drain Line

5

. . . . . . . . . . . . . . . . .

Waste Line Connection

5

. . . . . . . . . . . . . . . . . . . . . . . . .

Model Number Identification

6

. . . . . . . . . . . . . . . . . . . . .

SAFETY CONSIDERATIONS

Improper installation, adjustment, alteration, service,

maintenance, or use can cause explosion, fire, electrical

shock or other conditions which may cause death, personal

injury or property damage. Consult a qualified installer,

service agency, or your distributor or branch for information

or assistance. The qualified installer or agency must use

factory--authorized kits or accessories when modifying this

product. Refer to the individual instructions packaged with

the kits or accessories when installing.
Follow all safety codes. Wear safety glasses, protective

clothing and work gloves. Use quenching cloths for brazing

operations. Have fire extinguisher available. Read these

instructions thoroughly and follow all warnings or cautions

attached to the unit. Consult local building codes and the

current editions of the National Electrical Codes (NEC)

NFPA 70.
In Canada, refer to the current editions of the Canadian

Electrical Code CSA C22.1.
Recognize safety information. This is the safety--alert

symbol

. When you see this symbol on the unit and in

instructions or manuals, be alert to the potential for personal

injury.
Understand the signal words

DANGER

,

WARNING

and

CAUTION

. These words are used with the safety--alert

symbol.

DANGER

identifies the most serious hazards which

will

result in severe personal injury or death.

WARNING

signifies hazards which

could

result in personal injury or

death.

CAUTION

is used to identify unsafe practices, which

may

result in minor personal injury or product and property

damage.

NOTE

is used to highlight suggestions which

will

result in enhanced installation, reliability, or operation.

NOTE

: Nitrogen can leak out through the needle pierce

hole in the plugs. This does not indicate a leaking coil nor
warrant return of the coil.

ELECTRICAL SHOCK HAZARD

Failure to follow this warning could result in personal

injury or death.
Before installing, modifying or servicing system, always

turn off main power to system. There may be more than

one disconnect switch. Lock out and tag switch with a

suitable warning label.

!

WARNING

PERSONAL INJURY HAZARD

Failure to follow this caution may result in personal

injury.
This coil contains Nitrogen precharge of 15 PSIG.

Release of this pressure through the center of the

rubber plugs is required before removing the plugs.

CAUTION

!

CUT HAZARD

Failure to follow this caution may result in personal

injury.
Sheet metal parts may have sharp edges or burrs. Use

care and wear appropriate protective clothing and

gloves when handling parts.

CAUTION

!

Содержание ENH4X

Страница 1: ...itions of the Canadian Electrical Code CSA C22 1 Recognize safety information This is the safety alert symbol When you see this symbol on the unit and in instructions or manuals be alert to the potential for personal injury Understand the signal words DANGER WARNING and CAUTION These words are used with the safety alert symbol DANGER identifies the most serious hazards which will result in severe ...

Страница 2: ...ler Plate A08065 Figure 2 Horizontal Left Installation with Filler Plate Coil Ductwork Airflow Furnace Furnace Coil Ductwork Airflow Filler Plate Coil Ductwork Airflow Furnace Filler Plate Filler Plate A08066 Figure 3 Horizontal Right Installation with Filler Plate Airflow Airflow amount and distribution are vital to adequate system performance In addition heat pump applications require airflow in...

Страница 3: ...e application There should not be any gaps between the plastic condensate pan and the pan extension All condensate should flow from the pan extension to the plastic condensate pan and not leak into the coil cabinet or duct NOTE Discard the pan not used along with both shipping brackets 2 For horizontal left installation install pan extension onto left end of horizontal condensate pan Pan extension...

Страница 4: ... to four corners of coil casing see Figure 8 3 Use a minimum of two screws per corner to attach plumbers strap to casing 4 Position and secure coil in front of furnace discharge end 5 Make sure coil is level for proper condensate drainage 6 Using appropriate fasteners for duct type connect supply air duct to coil HORIZONTAL CRAWL SPACE INSTALLATION As an alternate to horizontal attic installation ...

Страница 5: ...D Failure to follow this caution may result in property damage When installing over a finished ceiling and or living area install a field fabricated secondary condensate pan under the entire unit CAUTION The coil is designed to dispose of accumulated water through built in condensate drain fittings It is recommended that PVC fittings be used on the condensate pan Do not over tighten Finger tighten...

Страница 6: ...nged period of time condensation can form on the bottom of pan and drip WASTE LINE CONNECTION If the condensate line is to be connected to a waste sewer line an open trap must be installed ahead of the waste line to prevent escape of sewer gases See Fig 10 A10216 Figure 10 Condensate Drain to Waste Line EXPLOSION HAZARD Failure to follow this warning could result in personal injury or death Provid...

Страница 7: ... P Piston X TXV METERING DEVICE 18 18 000 BTUH 1 tons 19 18 000 BTUH 1 tons 24 24 000 BTUH 2 tons 30 30 000 BTUH 2 tons 31 30 000 BTUH 2 tons 36 36 000 BTUH 3 tons 37 36 000 BTUH 3 tons 42 42 000 BTUH 3 tons 43 42 000 BTUH 3 tons 48 48 000 BTUH 4 tons 60 60 000 BTUH 5 tons 61 60 000 BTUH 5 tons NOMINAL CAPACITY C Plain Copper L Aluminum T Tin Coated Copper HAIRPIN MATERIAL 14 14 3 16 17 17 1 2 21 ...

Отзывы: