MaxiScan 3100 - Installation Guide
33
6 Slave mode
Debug slave mode
1. Use the EasySet "View - Data String" command to obtain the data strings for the
setup commands you want to send to the MaxiScan 3100.
Example: command "Code 39 active" = \41\4C\60
If you use "display data string mode" (see above), do not use the last 2 digits
(checksum).
2. Activate the debug slave mode (if not already active) and set the RS-232 output
parameters to suit your system (if required).
debug slave mode (9600, 7, E, 2) - interface n° 109
3. Send the commands in ASCII format from the host terminal to the MaxiScan 3100.
To save the new configuration, send the "update current configuration" command to
the MaxiScan 3100 (\46\41\02\60).