EasyCoder E4 Direct Protocol v2.10 – Programmer’s Reference Manual
23
Chapter 4
Label Design
Set Font Magnifi cation
Fonts can be magnifi ed 1 - 4 times independently with regard to
height and width using a
MAG
command.
MAG
<height mag>,<width mag>
<height mag>
the magnifi cation factor 1, 2, 3, or 4 times
with regard to height.
<width mag>
the magnifi cation factor 1, 2, 3, or 4 times
with regard to width.
Default:
1,1
Reset to default by:
PRINTFEED|PF
Specifying both a font height and two magnifi cation parameters
allows the user to control both the height and the aspect ratio of
printed characters. For example, to specify Swiss 721 Roman at
12 points with double width, use:
FONT "Swiss 721 BT",12,0
MAG 1,2
To specify Swiss 721 Roman at 12 points with a height:width
ratio of 2:3, use:
FONT "Swiss 721 BT",6,0
MAG 2,3
Select Normal/Inverse Printing
Normally, text is printed in black without any printed back-
ground (
NORIMAGE
). Using
INVIMAGE
, the printing can be
inversed so that the media gives the color of the characters,
whereas the background will be black. The size of the back-
ground is decided by the font size and slant. A
NORIMAGE
statement is only needed when changing back from
INVIMAGE
printing.
NORIMAGE
|
NI
INVIMAGE
|
II
Default:
NORIMAGE
Reset to default by:
PRINTFEED|PF
3. Text Field, cont.
NORIMAGE
INVIMAGE
Содержание EasyCoder E4