background image

1

700 Color Non-Incendive (NI) Zone 2 
EMEA Mobile Computer

Important Operating Instructions

Intermec Technologies Corporation Model 700CNI 
has been qualified under the ATEX Directive require-
ments of the European Union by DEMKO for use in 
Zone 2 environments. UL is the ExCB responsible for 
issuing the CoC under the IECEx scheme for use in the 
same environment.

Hazardous Locations

This mobile computer is suitable for use in the follow-
ing hazardous locations:

• Zone 2, II 3 G EEx nL IIC T6 Operating Tempera-

ture Range -10°C and +40°C (+14°F and +104°F).

• Zone 2, Ex nL IIC T6 from -10°C and +40°C 

(+14°F and +104°F).

Warnings and Cautions

All warnings and cautions herein must be observed for 
the safety of the operator and others in potentially haz-
ardous Zone 2 locations:

• The 700CNI must only be used when the ambient 

temperature is between -10°C and +40°C (+14°F 
and +104°F).

• Use battery pack P/N: 318-013-003 or 318-013-

004.

• The batteries may NOT be changed or charged in 

potentially hazardous locations.

• The 700CNI may NOT be connected to any of its 

available accessories while in potentially hazardous 
locations. This includes anything that uses the com-
munications docking connector, headset, or micro-
phone jacks.

Note

: Use of the 700CNI outdoors requires 

using the Intermec accessory cover (P/N: 
815-052-001).