Intermatic GRASSLIN thermio eco QE1 Скачать руководство пользователя страница 1

Zeitschaltuhr

Thermostat

Zähler

Lichtsteuerung

thermio

TM

 eco QE1/QE2

EN

Operating manual

0662_QE1_QE2.indd   1

29.03.2017   13:44:13

Содержание GRASSLIN thermio eco QE1

Страница 1: ...Zeitschaltuhr Thermostat Z hler Lichtsteuerung thermioTM eco QE1 QE2 EN Operating manual 0662_QE1_QE2 indd 1 29 03 2017 13 44 13...

Страница 2: ...rmore the local accident prevention regulations and the general safety regulations apply for the operating area of the device Copyright This manual is copyright protected Handover this manual to third...

Страница 3: ...78112 St Georgen GERMANY Declaration of conformity and download instructions The declaration of conformity for the device described in this manual a download of the manual and the technical data can b...

Страница 4: ...EN 4 Safety Information 5 Technical Data 6 Installation 7 Application Programming QE1 9 Application Programming QE2 26 Table of Contents 0662_QE1_QE2 indd 4 29 03 2017 13 44 13...

Страница 5: ...ock Incorrect assembly and installation of the device can result in life threatening electrical voltages Z Z This product should be installed by a qualified installer according to current installation...

Страница 6: ...plus after 70 hours charge Installation double insulated Fitting surface mounted or single gang plaster depth socket outlet Maximum ambient temperature 50 C Type 1 Action type 1B Micro disconnection t...

Страница 7: ...ve QE1 QE2 from packing and prepare it for use on fully pumped or for gravity hot water systems For gravity hot water systems no action is required For fully pumped systems the switch located at the r...

Страница 8: ...wired Remove backplate by slackening fixing screw and separate the plate from the timeswitch Remove the knock out from the backplate and the timeswitch Screw backplate to wall with counter sunk No 8 W...

Страница 9: ...standard program 13 Setting your own time program 14 View modify delete your entered program selections 16 Manual override functions boost advance constant OFF 17 Internal wiring diagram 19 General in...

Страница 10: ...n up to the stated rating Domestic heating systems where both heating and hot water services are required to switch ON and OFF at the same time Controlling a combi or combination boiler Application QE...

Страница 11: ...the display moves to indicate Summertime and the clock is correctly set 2 PROGRAMMING YOUR TOWERCHRON QE1 SETTING CURRENT TIME AND DAY Open the keypad cover Make sure that the slide switch is on posi...

Страница 12: ...switch to position RUN PRESET PROGRAM The inbuilt standard program is now active 3 START THE INBUILT STANDARD PROGRAM Move the slide switch to position RUN PRESET PROGRAM NB The inbuilt standard progr...

Страница 13: ...ys one step at a time the ON and OFF times for heating and hot water Standard program is shown in the table ON OFF ON OFF Monday to Friday 6 30 a m 8 30 a m 4 30 p m 10 30 p m Saturday to Sunday 8 00...

Страница 14: ...at were selected during ON time programming are still in memory for this OFF time 5 SETTING YOUR OWN TIME PROGRAM It is recommended that you write down the switching times The following day groups are...

Страница 15: ...WN PROGRAM The current time is displayed and your own program is now active 6 4 To store OFF time and view the next program space Press SELECT button Repeat steps 1 to 4 to enter further ON and OFF ti...

Страница 16: ...will be deleted To return time of day Move the slide switch to RUN OWN PROGRAM 7 VIEW MODIFY DELETE YOUR ENTERED PROGRAM SELECTIONS Move the slide switch to position SET OWN PROGRAM To view modify yo...

Страница 17: ...and without having to open the keypad cover you can manually override the program without disrupting the original settings by pressing the SELECT button TMD Timed When the RUN PRESET PROGRAM or RUN Y...

Страница 18: ...ing the permanently points to CONST Constant SELECT button again OFF Press the SELECT button The timeswitch stays OFF permanently To switch OFF until the arrow in the display until you move the arrow...

Страница 19: ...ug in unit and secure to the base by tightening fixing screw 10 INTERNAL WIRING DIAGRAM QE1 NB Carry out wiring installation using appropriate diagram as shown NB When the TOWERCHRON QE1 timeswitch is...

Страница 20: ...sleeved to prevent accidental contact with live parts 11 GENERAL INSTALLATION INSTRUCTIONS QE1 The TOWERCHRON QE1 is double insulated so earth protection is not required However i nal for earth conti...

Страница 21: ...2 Switchmaster SRT2 5 1 3 2 Sunvic TLX2259 E 4 3 1 12 WIRING INSTALLATION INSTRUCTIONS QE1 This diagram is correct for mains operated systems The link wire L 3 must be fitted by the installer E N COM...

Страница 22: ...135V N L 2 1 Saunier Duval SD 625M See special circuit N L E Supply Roomstat QE1 Terminals Important Note It is important that you always refer to the Boiler Manufacturers Instructions concerning elec...

Страница 23: ...18 72 DMCF N L 3 4 Vokera 21 84 DMCF N L 3 4 Vokera 21 84 DC Turbo N L 3 4 Vokera 20 80 RS Turbo N L 3 4 Worcester Heatslave Senior 12 N L 2 4 Worcester Heatslave Senior 20430 N L 2 4 Worcester Heatsl...

Страница 24: ...terminals 3 and 4 respectively on QE1 Boiler with Timeswitch and Room Thermostat 15 SAUNIER DUVAL SD625M Always use the special 24V thermostat supplied with this boiler and wire as indicated in boiler...

Страница 25: ...ELM Leblanc GVM 420 16 ELM Leblanc GVM 420 25 0662_QE1_QE2 indd 25 29 03 2017 13 44 16...

Страница 26: ...d program 30 Setting your own heating hot water program 32 View modify delete your entered program selections 38 Manual override functions boost advance constant OFF 40 General installation instructio...

Страница 27: ...Gravity hot water pumped heating systems with or without motorised valves fitted into the domestic hot water primary circuit Important note For fully pumped systems the switch located at the rear of...

Страница 28: ...ottom of the display moves to indicate Summertime and the clock is correctly set 20 PROGRAMMING YOUR TOWERCHRON QE2 SETTING CURRENT TIME AND DAY Open the keypad cover Make sure that the slide switch i...

Страница 29: ...h to position RUN PRESET PROGRAM The inbuilt standard program is now active 21 START THE INBUILT STANDARD PROGRAM Move the slide switch to position RUN PRESET PROGRAM NB The inbuilt standard program i...

Страница 30: ...ion RUN PRESET PROGRAM Repeatedly press the COPY button NB Each press displays one step at a time the ON and OFF times for heating and hot water Standard program is shown in the table HEATING SIDE HOT...

Страница 31: ...eturn to time of day Press the CLEAR button The preset programm is activated ON and OFF times for HEATING and HOT WATER ON OFF ON OFF Monday to Friday 6 30 a m 8 30 a m 4 30 p m 10 30 p m Saturday to...

Страница 32: ...nation Press HOUR then MINUTES buttons Press DAY button to select day day groups 24 SETTING YOUR OWN HEATING HOT WATER PROGRAM Both Heating and Hot Water will be turned ON and OFF at the same time It...

Страница 33: ...The display now jumps to the next free program space so that the OFF time can be input Repeat steps 1 to 2 to enter further ON and OFF times 28 program places are available After completing your own p...

Страница 34: ...re Heating ON time and view the next program space Press HEATING button 26 SETTING YOUR OWN HEATING HOT WATER PROGRAM Heating and hot water will be turned ON and OFF at different times 1 Setting your...

Страница 35: ...PROGRAM The current time is displayed and your own programis now active 27 3 To set the first Heating OFF time and day combination Press the HOUR then MINUTES buttons the day day groups that were sel...

Страница 36: ...e selected during ON time programming are still in memory for this OFF time 28 SETTING YOUR OWN HOT WATER TIMES Move the slide switch to position SET OWN PROGRAM Press the HOT WATER button The first p...

Страница 37: ...PROGRAM The current time is displayed and your own programis now active 29 4 To store Hot Water OFF time and day combination Press the HOT WATER button The next free program place is displayed Repeat...

Страница 38: ...m selection you can modify the contents with the DAY HOUR and MINUTES button 30 VIEW MODIFY DELETE YOUR ENTERED PROGRAM SELECTIONS Move the slide switch to position SET OWN PROGRAM To view modify your...

Страница 39: ...will be deleted To return time of day Press the RUN OWN PROGRAM button 31 To delete your entered program selections To delete Heating times Press the HEATING button repeatedly until the desired ON or...

Страница 40: ...mode and without having to open the keypad cover you can manually override the program without disrupting the original settings by pressing the SELECT button TMD Timed When the RUN PRESET PROGRAM or...

Страница 41: ...erride either program without disrupting the original settings by pressing the Select button TMD When the RUN PRESET PROGRAM or RUN YOUR OWN PROGRAM mode is active the arrow points to TMD Timed BOOST...

Страница 42: ...sleeved to prevent accidental contact with live parts 35 GENERAL INSTALLATIONS INSTRUCTIONS QE2 The TOWERCHRON QE2 is double insulated so earth protection is not required However in nal for earth cont...

Страница 43: ...ar of the QE2 must be moved to the right into the fully pumped position 36 INTERNAL WIRING DIAGRAM QE2 NB Carry out wiring installation using appropriate diagram as shown NB Plug in unit and secure to...

Страница 44: ...ructions Gravity Hot Water Pumped Heating System with roomstat controlled pump 37 WIRING INSTALLATION INSTRUCTIONS QE2 Gravity Hot Water Pumped Heating System with roomstat controlled pump 0662_QE1_QE...

Страница 45: ...re suitable 38 The following wiring diagrams are schematic only for clarity the earth and neutral connections are omitted We sug gest when wiring systems a suitable wiring centre is used the Tower con...

Страница 46: ...m using 2 Port Spring Return Fully Pumped System using 3 Port Mid Position Valve 39 Fully Pumped System using 2 Port Spring Return Fully Pumped System using 3 Port Mid Position Valve 0662_QE1_QE2 indd...

Страница 47: ...5 4 6 2 2 Switchmaster SRT2 5 1 3 Sunvic TLX2259 E 4 3 1 Conversion Chart for Room Cylinder Thermostats Room Stat Conversion Chart E COM DEM SAT ACL HTS 2 RED BLK YEL Drayton CS1 E 1 2 3 Honeywell L64...

Страница 48: ...Gr sslin GmbH Bundesstra e 36 78112 St Georgen Germany 49 0 7724 933 0 49 0 7724 933 240 www graesslin de info graesslin de 80 10 0662 7 0317 V03 0662_QE1_QE2 indd 48 29 03 2017 13 44 19...

Отзывы: