Description 

 

The Micro Door/Window Sensor is a 
supervised, wireless sensor that detects the 
opening and closing of doors or windows. 
The sensor and magnet are mounted using 
screws (included) or double-sided adhesive 
tape (included)  
 
When activated, the sensor transmits an 
open (trip) or close (restore) signal to the 
panel. These are the signals the unit 
provides: supervisory, tamper and low 
battery (as needed). The sensor is powered 
by (2) replaceable 3-VDC, lithium coin-cell 
batteries. 
 
 

Installation Guidelines 

 

• Mounting the sensor on metal can affect 
the transmitting range and magnet gap 
performance. Therefore, test the sensor 
from the desired location using the installer 
sensor test, before permanently mounting. 
  
• Mount the sensor within 100 ft. of the 
panel.  
 
• Mount the sensor on the frame, and the 
magnet on the door, window or drawer. If 
mounting on double doors, mount the 
sensor on the least used door and the 
magnet on the other door. 

 

     

 
• Mount sensors at least 5 inches above the 
floor to avoid damaging them.  
 
• The sensors can be mounted to either 
wood or metallic surfaces.  
 
• The magnet should be mounted within 
5/16” (8 mm) for wood or ¼” (6 mm) for 
metal installations. Based on the magnet 
mounting spacing, direction of operation 

and material of the mounting surface, the 
gap for opening will vary between 1/8” (3 
mm) and 1 ¾” (44 mm). Desired operation 
should be checked before permanent 
installation.  
 
• After mounting the sensor, retest the 
sensor using the procedure in the section 
“Testing the Sensor”. 
 

Programming 

 

The following steps describe the general 
guidelines for programming the sensor into 
panel memory. Refer to the specific panel’s 
documentation for complete programming 
details.  
 
1. Set the panel to the program mode. 
  
2. Proceed to the SENSORS menu. 
  
3. Select the appropriate sensor group and 
sensor number assignments. 
  
4. When prompted by the panel to trip the 
sensor for learning, remove the sensor 
cover and if present pull the battery pull 
tabs. The system should acknowledge 
learning the sensor by touchpad display 
and/or audio (depending on the panel).  
 
5. Exit program mode.  
 

Testing the Sensor  

 
1. Set the panel to the sensor test mode.  
 
2. Take the sensor and magnet to the 
desired mounting location, making sure to 
line up their alignment marks with each 
other. Trip the sensor by pulling the magnet 
away from the sensor.  
 
3. Monitor the system after tripping the 
sensor. Refer to the specific panel 
documentation for interpretation of the 
results to ensure desired signal strength is 
achieved.  