background image

feature, press the Save Energy button in the upper left corner of the unit. The 

screen will now read “Save Energy”. To return to normal operation, press the 

Save Energy button again. This is useful to save energy if your are going to be 

gone for a short time. 

MODE button 

The MODE button sets the thermostat to HEAT, COOL, or OFF modes. Press it 

once to step to the next mode. If the thermostat is in OFF mode and you want to 

return to the mode you were previously in, touch the OFF indicator on the screen. 

FAN button 

The fan control is normally in AUTO mode, meaning that the fan operates 

automatically with the HVAC system and the thermostat. When you press the 

FAN button, the fan goes on. The fan will run continuously in this manual 

override until switched back to AUTO by pressing the FAN button again. 

Note: 

The fan ON function is available in the OFF mode to allow simple 

ventilating. 

RESET button 

The RESET button reboots the thermostat processor. It does not effect the user 

programs that have been stored in permanent memory. 

Simple screen 

This display mode limits the amount of information on screen and limits the 

functions to just the +/- arrows and the Save Energy button. Hold down the Prog 

button for 10 seconds to access the limited display screen. Hold down the Prog 

button for 10 seconds to leave the limited display screen. 

Compressor protection 

The thermostat has a minimum cycle time of 4 minutes to protect your 

compressor in cool and in heat pump (if you have one). The Home screen will 

show a small clock and A/C during this time and the compressor will not come on 

until the 4-minute delay is over. 

Communicating thermostat 

The thermostat has two RTM-1 radio ports. These allow your thermostat to 

communicate with other systems. Depending on your area power company, 

programs may be available to connect your thermostat to power grid status 

information. This can make it easy for you to moderate your energy use at peak 

hours and use power when it is less expensive. 

P/N 1069511 • REV B • ISS 12FEB13 

Содержание IS-ZW-TSTAT-300

Страница 1: ...nitial settings 7 Auto run program 7 Other functions 8 Communicating thermostat 9 Specifications 10 Contact information For contact information see www interlogix com 2013 UTC Fire Security Americas Corporation Inc Interlogix is part of UTC Climate Controls Security a unit of United Technologies Corporation All rights reserved P N 1069511 REV B ISS 12FEB13 1 ...

Страница 2: ...or metallic device it will scratch the screen Figure 1 IS ZW TSTAT 300 LINK RADIO TARGET TEMP Top cover Bottom cover Wire terminals MODE button FAN button Menu button Prog button Reset button HVAC switches Save Energy button Power grid status indicator Touch screen Control screens Before you operate the thermostat you should get familiar with these basic control screens All the thermostat function...

Страница 3: ...ator To set a mode press the MODE button on the side of the thermostat The thermostat will step through the HEAT OFF and COOL modes in order The LCD display indicates the mode you are in Menu screen To display the Menu screen press the Menu button Figure 3 Menu screen Time Filter timer Temperature swing Chirp icon Home icon Lock icon HVAC setup Day Calibration control F C indicator Differential Us...

Страница 4: ... is 1 0 F Touch the Home icon to return to the MENU screen DIFF differential This feature is used for two stage normal or heat pump with aux only the feature is not on screen for single stage The differential is the number of degrees between the room temperature and the target temperature at which the second stage will be used The default is 2 F Touch DIFF Use the arrows to set the differential We...

Страница 5: ...tem Figure 4 Program screen Program time Time slot Temperature up arrow Temperature down arrow Home icon Program day Copy program Day Touch to set the day of the week for which you want to program target temperatures Time slot Touch to set the time slot MORN DAY EVEN or NITE you want to program Program time Touch to set the time of day you want the time period to start Left arrow goes back right a...

Страница 6: ...e target is set the same as the programmed target for that period the word TEMPORARY will not display HOLD Touch to operate the thermostat as a manual thermostat This will hold the target temperature you set indefinitely until you turn HOLD off Use care when using the HOLD function as the program is now bypassed To set a hold target temperature touch HOLD and use the icons to select your hold temp...

Страница 7: ...ve the time selection forward or backward until it displays the correct time You can touch and hold for faster setting To select F or C for the display touch the F to toggle to C or touch the C to toggle to F To set the audible chirp touch the musical note icon to toggle between chirp or no chirp To return to the Home screen touch the Home icon Auto run program The thermostat comes preprogrammed w...

Страница 8: ... program MORN DAY EVEN or NITE touch the time slot area to cycle through to the desired period To select the desired start time of that time slot touch the time arrows to display the desired starting time Hold the arrow down for fast time scrolling To select the desired target temperature for that time slot touch the arrows to display the desired temperature To copy one day s programming to the ne...

Страница 9: ...ET button reboots the thermostat processor It does not effect the user programs that have been stored in permanent memory Simple screen This display mode limits the amount of information on screen and limits the functions to just the arrows and the Save Energy button Hold down the Prog button for 10 seconds to access the limited display screen Hold down the Prog button for 10 seconds to leave the ...

Страница 10: ...VAC system and home conditions To insert a USNAP radio module power off the thermostat insert the radio module in either slot on the back of the thermostat and then power up the thermostat To connect to a network follow the instructions that come with the USNAP module Caution Do not insert or remove USNAP radio modules if power is on This can damage the thermostat or radio modules Specifications V...

Страница 11: ...s no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try and correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the e...

Страница 12: ...12 IS ZW TSTAT 300 Advanced Thermostat Operation Guide ...

Отзывы: