background image

 

© 2018 UTC Fire & Security Americas Corporation, Inc. 

1 / 4 

P/N 1069817 (ML) • REV C • ISS 23OCT18 

 

DC105 Series Magnetic Contact Installation 
Sheet 

EN  SV 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

EN: Installation Sheet 

Description 

DC105 series are flush mount magnetic contacts that can be 
connected to a burglar alarm system. Alternatively you can 
mount the magnet on a surface. DC105 series can be used in 
non-ferromagnetic environments and doors. 

Mounting 

The magnetic contact and the magnet should be mounted 
directly across from each other (see Figure 1). Select the 
desired mounting positions and drill 6.4 mm holes. Mount the 
magnet and the contact in the holes using glue. 

Alternatively, you can mount the DC105 series magnet on a 
surface. Use a surface mounting cover as shown in Figure 2. 
In this case the approach and removal distances may 
decrease. 

During installation the switching distances have to be 
individually determined for each contact. 

When the installation is completed, the electrical switch 
function of the magnetic contact must be checked (for 
example, with a continuity checker or multimeter). Use of 
mechanical force, for example when installing, can damage 
glass bodies of reed switches. 

Notes 

• 

When installing the contact please keep in mind that the 
doors can bend under temperature influence. 

• 

DC105 series contact is only EN 50131 certified for flush 
mounting of contact and magnet. 

Wiring description 

Colour 

Description 

1. 

2X Copper 

Tamper, supervision line 

2. 

2X Silver 

Alarm, normally closed 

Package content 

• 

1X Magnetic contact 

• 

1X Magnet 

• 

1X Surface mounting cover (DC105 only) 

• 

2X Surface mounting cover (DC105S8 only) 

• 

2X Spacer (DC105S8 only) 

• 

4X Screws (DC105S8 only) 

Specifications 

Cable length 

2.5 m 

Switch close resistance 

<2 

Ω 

Switch open resistance 

>10 

MΩ 

Mounted in non-ferromagnetic material

  

Approach distance Y (switch close) 

18 mm ±15% 

Removal distance Y (switch open) 

22 mm ±20% 

Approach distance Z (switch close) 

17 mm ±30% 

Removal distance Z (switch open) 

20 mm ±25% 

Contact type 

NC 

Contact dimensions 

Ø6.4 x 30 mm 

Magnet dimensions 

Ø6.4 x 30 mm 

Borehole diameter 

6.4 mm 

Maximum switch voltage 

50 V

 

Maximum switch current 

0.5 A 

0.25
6.4 mm

 in.

(1)

(2)

1

30 mm

 in.

1

30 mm

 in.

Z

Y

2.00 in.

50.8 mm

0.37
9.5 mm

 in.

0.37
9.5 mm

 in.

 

Отзывы: