Chapter 2: Installation
36
Advisor Advanced ATSx500A(-IP) Installation and Programming Manual
Maximum voltage at power supply, auxiliary
power output and battery power output
14.5 V
Battery low condition
From 9.5 to 10.5 V
Battery test level [6]
11.2 V
Minimum voltage (battery recharging) at
power supply, auxiliary power output and
battery power output [7][8]
9.45 V
Maximum ripple voltage V, p-p [9]
100 mV typical, 300 mV max.
Overvoltage trigger value [10]
15.5 V
min.
[1] The power supply voltage is monitored according EN 50131 Grade 3 and VdS-C regulations.
[2] Current available for auxiliary power and battery charge outputs.
[3] Maximum permanent current to power devices external to the control equipment in the
absence of alarm conditions. The sum of the auxiliary and COMM power output current
cannot exceed the maximum current specified in “Auxiliary current and battery capacity” on
[4] Battery output provides battery shortcut protection (according to VdS requirements).
[5] The housings applicable for particular batteries are specified in “Auxiliary current and battery
[6] If during a manual or a programmed battery test the battery voltage drops below this
threshold, the battery test fails.
[7] Deep discharge protection mechanism monitors the battery voltage and disconnects the
battery if the voltage falls below indicated value, as required by EN 50131 Grade 3 and VdS-
C regulations.
[8] A specific fail message is generated when any output fails.
[9] Max ripple voltage only when empty battery is charging.
[10] Overvoltage protection mechanism monitors the power supply voltage and shuts down the
PSU if the voltage raises above indicated value, as required by EN 50131 Grade 3 and VdS-
C regulations.
General features
ATS1500A(-IP) ATS3500A(-IP)
ATS4500A-IP
Code combinations
From 10,000 (4 digits) to 10 billion (10 digits)
End-of-line resistor
1 kΩ, 1.5 kΩ, 2 kΩ, 2.2 kΩ, 3.3 kΩ, 3.74 kΩ,
4.7 kΩ (default), 5.6 kΩ, 6.8 kΩ, 8.2 kΩ, 10 kΩ
Onboard zones
8 (expandable to 16 with 1X ATS608)
Maximum zone number
32
128
512
Onboard outputs
5 (expandable to 9 with 1X ATS624, or to 21 with
1X ATS626).
See “Standard onboard outputs” on page 37.
Maximum output number
128
Areas
4
8
64
Area groups
—
—
64
Maximum keypad / RAS number
8
16
32 [1]
Maximum expander / DGP number
7
15
30 [1]
[1] It is necessary to install ATS670 second RS485 LAN extension module to connect more
than 16 RASes and 15 DGPs.
Содержание ATS1500A-IP-LP
Страница 1: ...Advisor Advanced ATSx500A IP Installation and Programming Manual P N 466 2576 EN REV B ISS 16SEP16...
Страница 12: ...Chapter 1 Quick installation and programming 6 Advisor Advanced ATSx500A IP Installation and Programming Manual...
Страница 110: ...Chapter 3 System functions 104 Advisor Advanced ATSx500A IP Installation and Programming Manual...
Страница 300: ...Chapter 6 Software 294 Advisor Advanced ATSx500A IP Installation and Programming Manual...
Страница 306: ...Chapter 7 Troubleshooting 300 Advisor Advanced ATSx500A IP Installation and Programming Manual...
Страница 316: ...Chapter 8 Regulations 310 Advisor Advanced ATSx500A IP Installation and Programming Manual...
Страница 332: ...Appendix A Advisor Advanced events 326 Advisor Advanced ATSx500A IP Installation and Programming Manual...
Страница 348: ...Glossary 342 Advisor Advanced ATSx500A IP Installation and Programming Manual...