![Interlogix ATS125 Скачать руководство пользователя страница 11](http://html.mh-extra.com/html/interlogix/ats125/ats125_programming-manual_2077288011.webp)
ATS125x/1260 Four-Door/Four-Lift DGP Programming Guide
5
Add anti-passback facilities
For anti-passback to function, readers are required to enter and exit. The reader
address specifies if the reader is used as an IN (entry) or OUT (exit) reader (see
numbering).
Make sure both IN and OUT readers are available and are polled.
In the Advisor Master installer programming:
• Program timezones required for anti-passback
In the four-door/four-lift programming menu:
• Select menu 2-Door / Lift options and select the door to program
• Move to menu Access options
• Select if the IN / OUT reader inhibit region 0 user
• Select the required Anti-passback option
• Enter the IN / OUT reader region
Finding system codes for cards
System codes are very important as improper system codes will inhibit usage of
cards. The system code for a card can be seen as a number shared by a number
of cards. The cards will identify themselves by a card number that is unique.
It might happen the system code is unknown. The four-door/four-lift DGP can
provide some help finding the system code.
• Make sure a reader is active (activate polling if necessary)
• Make sure the card format is set correctly for that door.
• Enter menu 4-Display card.
• Badge a few cards. Make sure that the system code displayed is always the
same. If not, the card format is probably not correct. Re-adjust and restart in
menu 4.